Schmersal AZM400Z-ST-1P2P (Order No: 103003590) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -20 ... +55 °C; Ambient ...
Glorient offers competitive supply of Schmersal AZM400Z-ST-1P2P, Order No: 103003590. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to AZM400Z-ST-1P2P, Glorient also supplies:
| Gross weight | 764 g |
| Net weight | 764 g |
| Ambient temperature | -20 ... +55 °C |
| Ambient temperature, maximum | +55 °C |
| Ambient temperature, minimum | -20 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP66 |
| Certificates | cULus |
| Housing material | Light alloy die-casting |
| EAN (European Article Number) | 4030661472577 |
| Mission time | 20 |
| Termination | Connector M12, 8-pole, A-coded |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 46.7 mm |
| Width of sensor | 77.8 mm |
| Height of sensor | 156.7 mm |
| Utilisation category DC-13 | 24 VDC / 0.25 A |
| Required rated short-circuit current | 100 A |
| Note | The diagnostic output are not safety relevant outputs! |
| Traceparts | Yes |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
| Storage and transport temperature | -40 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -40 °C |
| Degree of pollution | 3 |
| Protection class | III |
| Other Parameters | Number of fail-safe digital outputs: 2 | Current consumption at 24V, maximum: 10 | Switching thresholds of the control inputs: 15 V … 30 V (High) | Note (LED switching conditions display): Error / functional defect: LED red | PFH value: 1.00 x 10⁻⁹ | PIN 3: A2 GND | Time to readiness, maximum: 1,500 | Design of control elements: short-circuit proof, p-type | Interlocking principle: bistable | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Lateral force at bolt return, maximal (against locked door): 300 | Minimal average cycle time (with continuous operation): 20 | PFD value: 9.00 x 10⁻⁵ | Coding level according to EN ISO 14119: Low | Note (Mechanical lifetime): Which have a lateral force Ftrans = 100 N: 100.000 operations | Allowed distance interlock to actuator, minimum: 1 | Cross-circuit detection: Yes | PIN 6: E3 Control input 3 | Rated operating voltage: 24 VDC | Voltage, Utilisation category DC-12: 24 | Category: 4 | Classification ZVEI CB24I, Source: C1 | Performance Level, up to: e | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded | PIN 8: E2 Control input 2 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | External wire and device fuse rating: 2 A gG | Note (Type of the fixing screws): Property class min. 10.9 | Safety Integrity Level (SIL), suitable for applications in: 3 | Coding: Universal coding | Minimum distance devices: 30 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | CADENAS: Yes | Utilisation category DC-12: 24 VDC / 0.25 A | Operating current while bolt movement, peak: 600 mA / 100 ms | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Permissible residual drive current: 1.5 | Classification ZVEI CB24I, Sink: C1 | Test pulse duration, maximum: 5 | Recommendation (actuator): AZM400-B1 | Designation, Control inputs: E1 und E2 (p-schaltend), E3 (n-schaltend) | TOL_VOLT_OPERAT_DC_MAX: 10 | Allowable discrepancy time (input), maximum: 10 | Allowed distance interlock to actuator, maximum: 7 | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Frequency band RFID: 125 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Number of diagnostic signals: 1 | TOL_VOLT_OPERAT_DC_MIN: -15 | Note (Lateral force at bolt return): Does not apply to emergency exit, Bowden cable and manual release | Switching frequency, maximum: 0.3 | Manual release: Yes | PIN 7: Y2 Safety output 2 | Voltage type: DC | PIN 2: E1 Control input 1 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Current consumption at 24V, minimum: 5 | Test pulse interval, typical: 1,000 | Electrical fuse rating, maximum: 2 | Open / close cycle (motor), minimum: 3 | Tightening torque of the screw: 8 | Designation, Safety outputs: Y1 and Y2 | ACE reference article number: 11930322 | Test pulse interval, maximum: 40 |