Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM400Z-ST-I2-1P2P

Schmersal AZM400Z-ST-I2-1P2P

Model: AZM400Z-ST-I2-1P2P
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 16 views

Products Introduction

Schmersal AZM400Z-ST-I2-1P2P (Order No: 103003733) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -20 ... +55 °C; Ambie...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM400Z-ST-I2-1P2P, Order No: 103003733. Competitive pricing, fast quotation.

Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.

More Schmersal Products from Glorient

In addition to AZM400Z-ST-I2-1P2P, Glorient also supplies:

SLC440COM-E-1050-14-1700 Order No: 103040470
ZR 335-02Z-M20 Order No: 151168109
SLC440COM-R-0890-35-1700 Order No: 103040559
SVE1/97-3Ö-24VDC Order No: 103000190
ZV14H 235-02Z Order No: 151145054
SHGV/R1.1/216+BO Order No: 101212480
TS 335-02Z Order No: 151082520
PS116-T12-STR-K250 Order No: 103006631
SVE3/SR/201GB/GR/201GB/GR/201GB/GR-24VDC Order No: 103015169
EX-SHGV/B01/112+BOWR-2GD Order No: 101199407
SLC440COM-R-1770-30 Order No: 103003998
AZM300Z-I2-ST-AS-T Order No: 103011892
BNS 33-12Z-2187 2,5M Order No: 101136444
TKF/STH/9024VDC Order No: 101022591
NBGLC11.1-NSK-NDRZ50BL/RT-2905-1/3NC-1NO Order No: 103031375
STW-SL-N-06-880-1-L2 Order No: 103047465
Z4V7H 332-11Y-M20-2138 Order No: 131169905
G50-017M44-1600-1/M44Y- 2281-3 Order No: 101182452
SHGV/ESS21S2/162/103 Order No: 101205889
HEBEL 3K KPL. 235/236 Order No: 101103200
SHGV/L01/48+BO Order No: 103035345
SLC440-ER-0170-30-01 Order No: 101216734
SHGV/D01/31+BO Order No: 101198257
MBGH311GB-EDRR40RT-2NC-1NO Order No: 103011534
SHGV/L01/216+BOF/HIS.1 Order No: 101198289
SVE3/133/133/133-3Ö-24VDC Order No: 103005701
SMS 4-900-900 Order No: 103024506
Z3K 235-11Z-M20 Order No: 151165850
DREHHEBELVORSATZ KPL. YT Order No: 101064603
RST 36-1-AD11 Order No: 103001562

Related Guides

Gross weight764 g
Net weight764 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatescULus
Housing materialLight alloy die-casting
EAN (European Article Number)4030661472614
Mission time20
TerminationConnector M12, 8-pole, A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor46.7 mm
Width of sensor77.8 mm
Height of sensor156.7 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
NoteThe diagnostic output are not safety relevant outputs!
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-40 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Degree of pollution3
Protection classIII
Other ParametersCoding: Individual coding, multiple teaching | Number of fail-safe digital outputs: 2 | Current consumption at 24V, maximum: 10 | Switching thresholds of the control inputs: 15 V … 30 V (High) | Note (LED switching conditions display): Error / functional defect: LED red | PFH value: 1.00 x 10⁻⁹ | PIN 3: A2 GND | Time to readiness, maximum: 1,500 | Design of control elements: short-circuit proof, p-type | Interlocking principle: bistable | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Lateral force at bolt return, maximal (against locked door): 300 | Minimal average cycle time (with continuous operation): 20 | PFD value: 9.00 x 10⁻⁵ | Note (Mechanical lifetime): Which have a lateral force Ftrans = 100 N: 100.000 operations | Allowed distance interlock to actuator, minimum: 1 | Cross-circuit detection: Yes | PIN 6: E3 Control input 3 | Rated operating voltage: 24 VDC | Voltage, Utilisation category DC-12: 24 | Category: 4 | Classification ZVEI CB24I, Source: C1 | Performance Level, up to: e | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 8: E2 Control input 2 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | External wire and device fuse rating: 2 A gG | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded | Note (Type of the fixing screws): Property class min. 10.9 | Safety Integrity Level (SIL), suitable for applications in: 3 | Minimum distance devices: 30 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | CADENAS: Yes | Utilisation category DC-12: 24 VDC / 0.25 A | Operating current while bolt movement, peak: 600 mA / 100 ms | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | ACE reference article number: 11930326 | Permissible residual drive current: 1.5 | Classification ZVEI CB24I, Sink: C1 | Test pulse duration, maximum: 5 | Recommendation (actuator): AZM400-B1 | Designation, Control inputs: E1 und E2 (p-schaltend), E3 (n-schaltend) | TOL_VOLT_OPERAT_DC_MAX: 10 | Allowable discrepancy time (input), maximum: 10 | Allowed distance interlock to actuator, maximum: 7 | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Number of diagnostic signals: 1 | TOL_VOLT_OPERAT_DC_MIN: -15 | Note (Lateral force at bolt return): Does not apply to emergency exit, Bowden cable and manual release | Switching frequency, maximum: 0.3 | Manual release: Yes | PIN 7: Y2 Safety output 2 | Voltage type: DC | PIN 2: E1 Control input 1 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Current consumption at 24V, minimum: 5 | Test pulse interval, typical: 1,000 | Electrical fuse rating, maximum: 2 | Open / close cycle (motor), minimum: 3 | Tightening torque of the screw: 8 | Designation, Safety outputs: Y1 and Y2 | Test pulse interval, maximum: 40