Schmersal AZM300B-ST-1P2P-T (Order No: 103006862) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: +0 ... +60 °C; Ambient...
Glorient offers competitive supply of Schmersal AZM300B-ST-1P2P-T, Order No: 103006862. Competitive pricing, fast quotation.
Schmersal AZM300B-ST-1P2P-T - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal AZM300B-ST-1P2P-T is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 610 g |
| Net weight | 610 g |
| Ambient temperature | +0 ... +60 °C |
| Ambient temperature, maximum | +60 °C |
| Ambient temperature, minimum | +0 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP66 |
| Certificates | TÜV, cULus, ECOLAB, FCC, IC, UKCA, ANATEL |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 4030661451060 |
| Mission time | 20 |
| Termination | Connector M12, 8-pole, A-coded |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 146 mm |
| Width of sensor | 87.5 mm |
| Height of sensor | 55 mm |
| Utilisation category DC-13 | 24 VDC / 0.05 A |
| Required rated short-circuit current | 100 A |
| Traceparts | Yes |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
| Storage and transport temperature | -10 ... +90 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +90 °C |
| Storage and transport temperature, minimum | -10 °C |
| Note (General) | For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. |
| Degree of pollution | 3 |
| Protection class | III |
| Other Parameters | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Power to unlock: Yes | Number of actuating directions: 3 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | External wire and device fuse rating: 2 A gG | Test pulse duration, maximum: 5 | Current consumption with magnet ON, peak: 350 mA / 200 ms | Safety Integrity Level (SIL), suitable for applications in: 2 | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Current consumption with magnet ON, average : 200 | Coding level according to EN ISO 14119: Low | Tightening torque of the fixing screws, maximum: 7 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | PFH value: 2.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Category: 4 | Latching force, adjustable, position 2: 50 | Connection type: Connector M12, 8-pole, A-coded | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Emergency exit: Yes | Actuator monitored: Yes | Operating current: 150 | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Latching force, adjustable, position 1: 25 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Latching force: 25 N / 50 N | Switching frequency, maximum: 0.5 | Type of the fixing screws: 2x M6 | Performance Level, up to: d | CADENAS: Yes | Note (Mechanical lifetime): When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Time to readiness, maximum: 5,000 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | Recommendation (actuator): AZ/AZM300-B1 | Tightening torque of the fixing screws: 6 ... 7 Nm | Reaction time, switching off safety outputs via actuator, maximum: 100 | Switch distance, typical: 2 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Operating voltage: 20.4 ... 26.4 VDC | Frequency band RFID: 125 | TOL_VOLT_OPERAT_DC_MIN: -15 | PFD value: 1.80 x 10⁻⁴ | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Permissible installation altitude above sea level, maximum: 3,000 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | WEB_TECH_DATA_BA: Yes | Latching force (position 1 / position 2): 25 N / 50 N | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded | Tightening torque of the fixing screws, minimum: 6 | Electrical fuse rating, maximum: 2 | Designation, Safety outputs: Y1 and Y2 | Degree of protection: IP66, IP67, IP69 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Wiring capacitance: 50 |
In addition to AZM300B-ST-1P2P-T, Glorient also supplies:
| Gross weight | 610 g |
| Net weight | 610 g |
| Ambient temperature | +0 ... +60 °C |
| Ambient temperature, maximum | +60 °C |
| Ambient temperature, minimum | +0 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP66 |
| Certificates | TÜV, cULus, ECOLAB, FCC, IC, UKCA, ANATEL |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 4030661451060 |
| Mission time | 20 |
| Termination | Connector M12, 8-pole, A-coded |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 146 mm |
| Width of sensor | 87.5 mm |
| Height of sensor | 55 mm |
| Utilisation category DC-13 | 24 VDC / 0.05 A |
| Required rated short-circuit current | 100 A |
| Traceparts | Yes |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
| Storage and transport temperature | -10 ... +90 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +90 °C |
| Storage and transport temperature, minimum | -10 °C |
| Note (General) | For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. |
| Degree of pollution | 3 |
| Protection class | III |
| Other Parameters | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Power to unlock: Yes | Number of actuating directions: 3 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | External wire and device fuse rating: 2 A gG | Test pulse duration, maximum: 5 | Current consumption with magnet ON, peak: 350 mA / 200 ms | Safety Integrity Level (SIL), suitable for applications in: 2 | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Current consumption with magnet ON, average : 200 | Coding level according to EN ISO 14119: Low | Tightening torque of the fixing screws, maximum: 7 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | PFH value: 2.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Category: 4 | Latching force, adjustable, position 2: 50 | Connection type: Connector M12, 8-pole, A-coded | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Emergency exit: Yes | Actuator monitored: Yes | Operating current: 150 | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Latching force, adjustable, position 1: 25 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Latching force: 25 N / 50 N | Switching frequency, maximum: 0.5 | Type of the fixing screws: 2x M6 | Performance Level, up to: d | CADENAS: Yes | Note (Mechanical lifetime): When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Time to readiness, maximum: 5,000 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | Recommendation (actuator): AZ/AZM300-B1 | Tightening torque of the fixing screws: 6 ... 7 Nm | Reaction time, switching off safety outputs via actuator, maximum: 100 | Switch distance, typical: 2 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Operating voltage: 20.4 ... 26.4 VDC | Frequency band RFID: 125 | TOL_VOLT_OPERAT_DC_MIN: -15 | PFD value: 1.80 x 10⁻⁴ | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Permissible installation altitude above sea level, maximum: 3,000 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | WEB_TECH_DATA_BA: Yes | Latching force (position 1 / position 2): 25 N / 50 N | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded | Tightening torque of the fixing screws, minimum: 6 | Electrical fuse rating, maximum: 2 | Designation, Safety outputs: Y1 and Y2 | Degree of protection: IP66, IP67, IP69 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Wiring capacitance: 50 |