Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM300B-ST-1P2P-T

Schmersal AZM300B-ST-1P2P-T

Model: AZM300B-ST-1P2P-T
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 20 views

Products Introduction

Schmersal AZM300B-ST-1P2P-T (Order No: 103006862) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: +0 ... +60 °C; Ambient...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM300B-ST-1P2P-T, Order No: 103006862. Competitive pricing, fast quotation.

Schmersal AZM300B-ST-1P2P-T - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM300B-ST-1P2P-T is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight610 g
Net weight610 g
Ambient temperature+0 ... +60 °C
Ambient temperature, maximum+60 °C
Ambient temperature, minimum+0 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, ECOLAB, FCC, IC, UKCA, ANATEL
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661451060
Mission time20
TerminationConnector M12, 8-pole, A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor146 mm
Width of sensor87.5 mm
Height of sensor55 mm
Utilisation category DC-1324 VDC / 0.05 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-10 ... +90 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+90 °C
Storage and transport temperature, minimum-10 °C
Note (General)For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.
Degree of pollution3
Protection classIII
Other ParametersNumber of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Power to unlock: Yes | Number of actuating directions: 3 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | External wire and device fuse rating: 2 A gG | Test pulse duration, maximum: 5 | Current consumption with magnet ON, peak: 350 mA / 200 ms | Safety Integrity Level (SIL), suitable for applications in: 2 | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Current consumption with magnet ON, average : 200 | Coding level according to EN ISO 14119: Low | Tightening torque of the fixing screws, maximum: 7 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | PFH value: 2.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Category: 4 | Latching force, adjustable, position 2: 50 | Connection type: Connector M12, 8-pole, A-coded | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Emergency exit: Yes | Actuator monitored: Yes | Operating current: 150 | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Latching force, adjustable, position 1: 25 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Latching force: 25 N / 50 N | Switching frequency, maximum: 0.5 | Type of the fixing screws: 2x M6 | Performance Level, up to: d | CADENAS: Yes | Note (Mechanical lifetime): When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Time to readiness, maximum: 5,000 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | Recommendation (actuator): AZ/AZM300-B1 | Tightening torque of the fixing screws: 6 ... 7 Nm | Reaction time, switching off safety outputs via actuator, maximum: 100 | Switch distance, typical: 2 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Operating voltage: 20.4 ... 26.4 VDC | Frequency band RFID: 125 | TOL_VOLT_OPERAT_DC_MIN: -15 | PFD value: 1.80 x 10⁻⁴ | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Permissible installation altitude above sea level, maximum: 3,000 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | WEB_TECH_DATA_BA: Yes | Latching force (position 1 / position 2): 25 N / 50 N | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded | Tightening torque of the fixing screws, minimum: 6 | Electrical fuse rating, maximum: 2 | Designation, Safety outputs: Y1 and Y2 | Degree of protection: IP66, IP67, IP69 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Wiring capacitance: 50

More Schmersal Products from Glorient

In addition to AZM300B-ST-1P2P-T, Glorient also supplies:

TZF24VDC Order No: 131010266
PS215-Z12-K250 Order No: 103014969
SVE2/155/155-3Ö-24VDC Order No: 103035506
TR 355-02Z Order No: 151082443
G50-017M22/22y-1601-4-1368-2 Order No: 103037344
EX-TS335-11Y Order No: 151211813
SHGV/LD1/210/37+BOW Order No: 103002977
BN 85-R-1824-3 1,65M Order No: 103050081
AZM 170-02ZRKA 110VAC Order No: 101136315
Z4V10H 335-11Z-1557-1 Order No: 151087262
HEBEL H KPL. 015-471 Order No: 101064133
T4V10H 336-11Z-M20 Order No: 151165849
T4V7H 355-02Z-M20 Order No: 151169624
PS316-T12-S300 Order No: 103015148
BNS 180-12Z-2187-2 3,0M Order No: 101184069
T3C 236-11Z-M20 Order No: 151162012
T4V10H 335-20Z Order No: 151082578
PS316-Z11-S300 Order No: 103015129
ACC-NRS-M4X12-FHS-A2-2PCS Order No: 103050555
AZM 161-STS30-07R Order No: 101178596
BNS 120-11Z 15,0M Order No: 101176445
SVE1/230EDTRWS/EMLWS-24VDC Order No: 101197711
SHGV/RD1/212/43+BO Order No: 101198600
EDLWS/801 Order No: 101187437
SMS 4-750-1300 Order No: 101215877
TFH 232-31 Order No: 151188723
ZQ Order No: 101022404
TKM/.L/92/9024VDC Order No: 101029557
FLANSCH FL2 MIT SCHRAUBEN Order No: 101096797
SLC240COM-ER-0650-30 Order No: 103016162

Related Guides

Gross weight610 g
Net weight610 g
Ambient temperature+0 ... +60 °C
Ambient temperature, maximum+60 °C
Ambient temperature, minimum+0 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, ECOLAB, FCC, IC, UKCA, ANATEL
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661451060
Mission time20
TerminationConnector M12, 8-pole, A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor146 mm
Width of sensor87.5 mm
Height of sensor55 mm
Utilisation category DC-1324 VDC / 0.05 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-10 ... +90 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+90 °C
Storage and transport temperature, minimum-10 °C
Note (General)For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.
Degree of pollution3
Protection classIII
Other ParametersNumber of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Power to unlock: Yes | Number of actuating directions: 3 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | External wire and device fuse rating: 2 A gG | Test pulse duration, maximum: 5 | Current consumption with magnet ON, peak: 350 mA / 200 ms | Safety Integrity Level (SIL), suitable for applications in: 2 | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Current consumption with magnet ON, average : 200 | Coding level according to EN ISO 14119: Low | Tightening torque of the fixing screws, maximum: 7 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | PFH value: 2.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Category: 4 | Latching force, adjustable, position 2: 50 | Connection type: Connector M12, 8-pole, A-coded | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Emergency exit: Yes | Actuator monitored: Yes | Operating current: 150 | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Latching force, adjustable, position 1: 25 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Latching force: 25 N / 50 N | Switching frequency, maximum: 0.5 | Type of the fixing screws: 2x M6 | Performance Level, up to: d | CADENAS: Yes | Note (Mechanical lifetime): When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Time to readiness, maximum: 5,000 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | Recommendation (actuator): AZ/AZM300-B1 | Tightening torque of the fixing screws: 6 ... 7 Nm | Reaction time, switching off safety outputs via actuator, maximum: 100 | Switch distance, typical: 2 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Operating voltage: 20.4 ... 26.4 VDC | Frequency band RFID: 125 | TOL_VOLT_OPERAT_DC_MIN: -15 | PFD value: 1.80 x 10⁻⁴ | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Permissible installation altitude above sea level, maximum: 3,000 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | WEB_TECH_DATA_BA: Yes | Latching force (position 1 / position 2): 25 N / 50 N | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded | Tightening torque of the fixing screws, minimum: 6 | Electrical fuse rating, maximum: 2 | Designation, Safety outputs: Y1 and Y2 | Degree of protection: IP66, IP67, IP69 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Wiring capacitance: 50