Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM300Z-I2-ST-1P2P-T

Schmersal AZM300Z-I2-ST-1P2P-T

Model: AZM300Z-I2-ST-1P2P-T
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 19 views

Products Introduction

Schmersal AZM300Z-I2-ST-1P2P-T (Order No: 103006863) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: +0 ... +60 °C; Ambi...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM300Z-I2-ST-1P2P-T, Order No: 103006863. Competitive pricing, fast quotation.

Schmersal AZM300Z-I2-ST-1P2P-T - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM300Z-I2-ST-1P2P-T is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight639 g
Net weight639 g
Ambient temperature+0 ... +60 °C
Ambient temperature, maximum+60 °C
Ambient temperature, minimum+0 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, ECOLAB, FCC, IC, UKCA, ANATEL
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661451077
Mission time20
TerminationConnector M12, 8-pole, A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor146 mm
Width of sensor87.5 mm
Height of sensor55 mm
Utilisation category DC-1324 VDC / 0.05 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-10 ... +90 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+90 °C
Storage and transport temperature, minimum-10 °C
Note (General)For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.
Degree of pollution3
Protection classIII
Other ParametersCoding: Individual coding, multiple teaching | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Power to unlock: Yes | Number of actuating directions: 3 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | External wire and device fuse rating: 2 A gG | Category: 2 | Test pulse duration, maximum: 5 | Current consumption with magnet ON, peak: 350 mA / 200 ms | Safety Integrity Level (SIL), suitable for applications in: 2 | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Current consumption with magnet ON, average : 200 | Tightening torque of the fixing screws, maximum: 7 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | ACE reference article number: 11930861 | Cross-circuit detection: Yes | PFH value: 2.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Latching force, adjustable, position 2: 50 | Connection type: Connector M12, 8-pole, A-coded | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Emergency exit: Yes | Operating current: 150 | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Latching force, adjustable, position 1: 25 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Latching force: 25 N / 50 N | Switching frequency, maximum: 0.5 | Type of the fixing screws: 2x M6 | Performance Level, up to: d | CADENAS: Yes | Note (Mechanical lifetime): When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Time to readiness, maximum: 5,000 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | Recommendation (actuator): AZ/AZM300-B1 | Tightening torque of the fixing screws: 6 ... 7 Nm | Reaction time, switching off safety outputs via actuator, maximum: 100 | Switch distance, typical: 2 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Operating voltage: 20.4 ... 26.4 VDC | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | TOL_VOLT_OPERAT_DC_MIN: -15 | PFD value: 1.80 x 10⁻⁴ | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Permissible installation altitude above sea level, maximum: 3,000 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | WEB_TECH_DATA_BA: Yes | Latching force (position 1 / position 2): 25 N / 50 N | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Tightening torque of the fixing screws, minimum: 6 | Electrical fuse rating: short-circuit proof, p-type | Electrical fuse rating, maximum: 2 | Designation, Safety outputs: Y1 and Y2 | Degree of protection: IP66, IP67, IP69 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Wiring capacitance: 50 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded

More Schmersal Products from Glorient

In addition to AZM300Z-I2-ST-1P2P-T, Glorient also supplies:

SMS 4-650-1200-0169 Order No: 103008135
NDLWS/501D Order No: 101189675
TF 232-40HD Order No: 101182010
WKTSC521.2 Order No: 101019588
NDTBL/GB/107D Order No: 103012895
WELLE 336 SPEZ 1583-2 Order No: 101086123
TV14H 236-11Z-M20 Order No: 151166965
WKSE521/WKT-19.3 Order No: 101204022
SHGV/D01/215+BOW Order No: 101212631
G150-220Z11/11Y Order No: 101063389
SVM1/76-6/126/A Order No: 101213508
SVM1/65-10/215/E Order No: 103008512
BNS 303-11Z 3,0M Order No: 101121966
STW-SL-N-05-3600-2-L2 Order No: 103042494
M 630-11-2 Order No: 101140265
WTCN32 Order No: 101007438
SVM1/65-10/115/E Order No: 101213606
SMS 4-930-1150 Order No: 103044428
TRAEGERPROFIL L1 = 450 Order No: 101169236
SLB240-ER-3-LST Order No: 103013531
PS226-Z12-H200 Order No: 103015066
T4VH 336-11Z-M20 Order No: 151158892
TV7H 236-20Z-2138 Order No: 151185079
AZM400Z-ST-I2-1P2P-BOW Order No: 103015315
TS 335-20Z-ST Order No: 153002581
M4D 250-11Z-T-R=2X90GR Order No: 103010634
BNS 33-11ZG 3,0M Order No: 101110790

Related Guides

Gross weight639 g
Net weight639 g
Ambient temperature+0 ... +60 °C
Ambient temperature, maximum+60 °C
Ambient temperature, minimum+0 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, ECOLAB, FCC, IC, UKCA, ANATEL
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661451077
Mission time20
TerminationConnector M12, 8-pole, A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor146 mm
Width of sensor87.5 mm
Height of sensor55 mm
Utilisation category DC-1324 VDC / 0.05 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-10 ... +90 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+90 °C
Storage and transport temperature, minimum-10 °C
Note (General)For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.
Degree of pollution3
Protection classIII
Other ParametersCoding: Individual coding, multiple teaching | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Power to unlock: Yes | Number of actuating directions: 3 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | External wire and device fuse rating: 2 A gG | Category: 2 | Test pulse duration, maximum: 5 | Current consumption with magnet ON, peak: 350 mA / 200 ms | Safety Integrity Level (SIL), suitable for applications in: 2 | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Current consumption with magnet ON, average : 200 | Tightening torque of the fixing screws, maximum: 7 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | ACE reference article number: 11930861 | Cross-circuit detection: Yes | PFH value: 2.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Latching force, adjustable, position 2: 50 | Connection type: Connector M12, 8-pole, A-coded | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Emergency exit: Yes | Operating current: 150 | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Latching force, adjustable, position 1: 25 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Latching force: 25 N / 50 N | Switching frequency, maximum: 0.5 | Type of the fixing screws: 2x M6 | Performance Level, up to: d | CADENAS: Yes | Note (Mechanical lifetime): When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Time to readiness, maximum: 5,000 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | Recommendation (actuator): AZ/AZM300-B1 | Tightening torque of the fixing screws: 6 ... 7 Nm | Reaction time, switching off safety outputs via actuator, maximum: 100 | Switch distance, typical: 2 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Operating voltage: 20.4 ... 26.4 VDC | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | TOL_VOLT_OPERAT_DC_MIN: -15 | PFD value: 1.80 x 10⁻⁴ | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Permissible installation altitude above sea level, maximum: 3,000 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | WEB_TECH_DATA_BA: Yes | Latching force (position 1 / position 2): 25 N / 50 N | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Tightening torque of the fixing screws, minimum: 6 | Electrical fuse rating: short-circuit proof, p-type | Electrical fuse rating, maximum: 2 | Designation, Safety outputs: Y1 and Y2 | Degree of protection: IP66, IP67, IP69 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Wiring capacitance: 50 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded