Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM300Z-ST-1P2P-T

Schmersal AZM300Z-ST-1P2P-T

Model: AZM300Z-ST-1P2P-T
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 19 views

Products Introduction

Schmersal AZM300Z-ST-1P2P-T (Order No: 103006865) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: +0 ... +60 °C; Ambient...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM300Z-ST-1P2P-T, Order No: 103006865. Competitive pricing, fast quotation.

Schmersal AZM300Z-ST-1P2P-T - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM300Z-ST-1P2P-T is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight610 g
Net weight610 g
Ambient temperature+0 ... +60 °C
Ambient temperature, maximum+60 °C
Ambient temperature, minimum+0 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, ECOLAB, FCC, IC, UKCA, ANATEL
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661451084
Mission time20
TerminationConnector M12, 8-pole, A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor146 mm
Width of sensor87.5 mm
Height of sensor55 mm
Utilisation category DC-1324 VDC / 0.05 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-10 ... +90 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+90 °C
Storage and transport temperature, minimum-10 °C
Note (General)For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.
Degree of pollution3
Protection classIII
Other ParametersNumber of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Power to unlock: Yes | Number of actuating directions: 3 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | External wire and device fuse rating: 2 A gG | Category: 2 | Test pulse duration, maximum: 5 | Current consumption with magnet ON, peak: 350 mA / 200 ms | Safety Integrity Level (SIL), suitable for applications in: 2 | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Current consumption with magnet ON, average : 200 | Coding level according to EN ISO 14119: Low | Tightening torque of the fixing screws, maximum: 7 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | PFH value: 2.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Latching force, adjustable, position 2: 50 | Connection type: Connector M12, 8-pole, A-coded | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | ACE reference article number: 11930241 | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Emergency exit: Yes | Operating current: 150 | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded | Latching force, adjustable, position 1: 25 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Latching force: 25 N / 50 N | Switching frequency, maximum: 0.5 | Type of the fixing screws: 2x M6 | Performance Level, up to: d | CADENAS: Yes | Note (Mechanical lifetime): When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Time to readiness, maximum: 5,000 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | Recommendation (actuator): AZ/AZM300-B1 | Tightening torque of the fixing screws: 6 ... 7 Nm | Reaction time, switching off safety outputs via actuator, maximum: 100 | Switch distance, typical: 2 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Operating voltage: 20.4 ... 26.4 VDC | Frequency band RFID: 125 | TOL_VOLT_OPERAT_DC_MIN: -15 | PFD value: 1.80 x 10⁻⁴ | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Permissible installation altitude above sea level, maximum: 3,000 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | WEB_TECH_DATA_BA: Yes | Latching force (position 1 / position 2): 25 N / 50 N | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Tightening torque of the fixing screws, minimum: 6 | Electrical fuse rating, maximum: 2 | Designation, Safety outputs: Y1 and Y2 | Degree of protection: IP66, IP67, IP69 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Wiring capacitance: 50

More Schmersal Products from Glorient

In addition to AZM300Z-ST-1P2P-T, Glorient also supplies:

ENA11.044 Order No: 101023649
ACC-PFB-SFB-SLLAB-4PCS Order No: 103013919
IFL 10-30-10/01A Order No: 101154799
Z 6881-11-1-P7 Order No: 101151309
EX-T. 441-11Y-UE-243-1276-2 Order No: 103002925
BNS 260-02/01Z-R Order No: 101184370
EF033.2 Order No: 101006545
PS316-Z11-S200 Order No: 103015409
SHGV/B01/255+BOW Order No: 103035541
SLG440-ER-0900-04-01 Order No: 101216823
BNS-B20-12ZG-R Order No: 101186265
REL. 12V SFS-3 12V PAN Order No: 101210316
SHGV/L01/232+BO Order No: 101197913
NDTP30BL/WS Order No: 103009735
IFL 10-30L-10/01P Order No: 101127017
ZV1H 235-02Z Order No: 151145025
BDF200-LMRD-11-LMYE-LMBU-LMGN Order No: 103010246
SVM1/51-6/233/E Order No: 103034705
SVM1/92-6/142/E Order No: 103010540
EDP40BL Order No: 101006301
NBG633 Order No: 101180083
BEST.PL. 3331-SMZ-04BX Order No: 103014597
SVM1/56-6/217/E Order No: 103006487
BDF200-LT-11-LT-SWS20-LT-2875 Order No: 103040526
TV7H 015-11Y Order No: 101058062
AZM 161ST-01/11RK-024- 2545 Order No: 101186309
Z3K 235-11Z-M20 Order No: 151165850

Related Guides

Gross weight610 g
Net weight610 g
Ambient temperature+0 ... +60 °C
Ambient temperature, maximum+60 °C
Ambient temperature, minimum+0 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, ECOLAB, FCC, IC, UKCA, ANATEL
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661451084
Mission time20
TerminationConnector M12, 8-pole, A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor146 mm
Width of sensor87.5 mm
Height of sensor55 mm
Utilisation category DC-1324 VDC / 0.05 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-10 ... +90 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+90 °C
Storage and transport temperature, minimum-10 °C
Note (General)For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.
Degree of pollution3
Protection classIII
Other ParametersNumber of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Power to unlock: Yes | Number of actuating directions: 3 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | External wire and device fuse rating: 2 A gG | Category: 2 | Test pulse duration, maximum: 5 | Current consumption with magnet ON, peak: 350 mA / 200 ms | Safety Integrity Level (SIL), suitable for applications in: 2 | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Current consumption with magnet ON, average : 200 | Coding level according to EN ISO 14119: Low | Tightening torque of the fixing screws, maximum: 7 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | PFH value: 2.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Latching force, adjustable, position 2: 50 | Connection type: Connector M12, 8-pole, A-coded | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | ACE reference article number: 11930241 | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Emergency exit: Yes | Operating current: 150 | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded | Latching force, adjustable, position 1: 25 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Latching force: 25 N / 50 N | Switching frequency, maximum: 0.5 | Type of the fixing screws: 2x M6 | Performance Level, up to: d | CADENAS: Yes | Note (Mechanical lifetime): When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Time to readiness, maximum: 5,000 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | Recommendation (actuator): AZ/AZM300-B1 | Tightening torque of the fixing screws: 6 ... 7 Nm | Reaction time, switching off safety outputs via actuator, maximum: 100 | Switch distance, typical: 2 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Operating voltage: 20.4 ... 26.4 VDC | Frequency band RFID: 125 | TOL_VOLT_OPERAT_DC_MIN: -15 | PFD value: 1.80 x 10⁻⁴ | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Permissible installation altitude above sea level, maximum: 3,000 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | WEB_TECH_DATA_BA: Yes | Latching force (position 1 / position 2): 25 N / 50 N | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Tightening torque of the fixing screws, minimum: 6 | Electrical fuse rating, maximum: 2 | Designation, Safety outputs: Y1 and Y2 | Degree of protection: IP66, IP67, IP69 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Wiring capacitance: 50