Schmersal EX-CSS 8-180-2P+D-M-L-3G/D-10M (Order No: 103011483) is a genuine explosion-proof switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 .....
Glorient offers competitive supply of Schmersal EX-CSS 8-180-2P+D-M-L-3G/D-10M, Order No: 103011483. Competitive pricing, fast quotation.
Schmersal EX-CSS 8-180-2P+D-M-L-3G/D-10M - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal EX-CSS 8-180-2P+D-M-L-3G/D-10M is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 533 g |
| Net weight | 533 g |
| Ambient temperature | -25 ... +40 °C |
| Ambient temperature, maximum | +40 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 61508 |
| IP Degree of protection | IP67 |
| Certificates | TÜV, UKCA, ATEX (Konformitätserklärung) |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 4030661478425 |
| Mission time | 20 |
| Termination | cable |
| Length of sensor | 92 mm |
| Utilisation category DC-13 | 24 VDC / 0.5 A |
| Housing construction form | Cylinder, thread |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Degree of pollution | 3 |
| Protection class | II |
| Other Parameters | Terminal connector, Output: 7-pole | Number of fail-safe digital outputs: 2 | PIN 3: A2 GND Blue | Short circuit detection: Yes | Integral system diagnostics, status: Yes | width across flats: 24 | PIN 5: X1 Safety input 1 violet | Operating voltage, maximum: 26.4 | Utilisation category DC-12: 24_0.5 | Cross-circuit detection: Yes | Rated operating voltage: 24 VDC | Voltage, Utilisation category DC-12: 24 | Working principle: inductive | Note (Characteristic curve): Soff: Switch-off distance | Restistance to shock: 30 g / 11 ms | Design of control elements: p-type | Material of the nuts: Glass-fibre, reinforced thermoplastic | Impact energy, maximum: 2 | Protection class (Operating resource): 2 | Explosion protection category: 3G | Wire cross-section: 0.25 | Manufacturer declaration: ATEX Zone 2 and 22 | Explosion protection: regulations: EN IEC 60079-0 | Operating voltage: 24 VDC -15 % / +10 % | PFH value: 2.50 x 10⁻⁹ | PIN 2: Y2 Safety output 2 red | Hysteresis (Switching distance), maximum: 0.7 | ISO thread of the sensor: M18 | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Operating voltage, minimum: 20.4 | Current, Utilisation category DC-12: 0.05 | Note (LED switching conditions display): Multi-coloured LED: Green, Red, Yellow | PIN 1: A1 Ue Brown | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | Scope of delivery of mounting material: 2x nuts M18 x 1 | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | PIN 7: Signalling output Grey | Category: 4 | Recommendation (actuator): CST 180-2 | Operating current: 1,000 | TOL_VOLT_OPERAT_DC_MAX: 10 | Tightening torque of nuts, maximum: 3 | Switching frequency, approx.: 3 | PIN 6: X2 Safety input 2 White | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Number of cable wires: 7 | Number of semi-conductor outputs with signaling function: 1 | Active area: Glass-fibre, reinforced thermoplastic | Length of cable: 10 | Duration of risk, maximum: 30 | Voltage type: DC | Number of series-wiring of sensors: 16 | Repeat accuracy R: 0.2 | PIN 4: Y1 Safety output 1 Black | Absicherung des Sicherheitsausganges: short-circuit proof, p-type | Overvoltage category: 3 | Explosion protection zones: 22 | Traceparts, product ID: 33-22052019-077908 | Electrical fuse rating: short-circuit proof, p-type | Switch distance, typical: 8 | Reaction time, maximum: 30 | Performance Level, up to: e |
In addition to EX-CSS 8-180-2P+D-M-L-3G/D-10M, Glorient also supplies:
| Gross weight | 533 g |
| Net weight | 533 g |
| Ambient temperature | -25 ... +40 °C |
| Ambient temperature, maximum | +40 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 61508 |
| IP Degree of protection | IP67 |
| Certificates | TÜV, UKCA, ATEX (Konformitätserklärung) |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 4030661478425 |
| Mission time | 20 |
| Termination | cable |
| Length of sensor | 92 mm |
| Utilisation category DC-13 | 24 VDC / 0.5 A |
| Housing construction form | Cylinder, thread |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Degree of pollution | 3 |
| Protection class | II |
| Other Parameters | Terminal connector, Output: 7-pole | Number of fail-safe digital outputs: 2 | PIN 3: A2 GND Blue | Short circuit detection: Yes | Integral system diagnostics, status: Yes | width across flats: 24 | PIN 5: X1 Safety input 1 violet | Operating voltage, maximum: 26.4 | Utilisation category DC-12: 24_0.5 | Cross-circuit detection: Yes | Rated operating voltage: 24 VDC | Voltage, Utilisation category DC-12: 24 | Working principle: inductive | Note (Characteristic curve): Soff: Switch-off distance | Restistance to shock: 30 g / 11 ms | Design of control elements: p-type | Material of the nuts: Glass-fibre, reinforced thermoplastic | Impact energy, maximum: 2 | Protection class (Operating resource): 2 | Explosion protection category: 3G | Wire cross-section: 0.25 | Manufacturer declaration: ATEX Zone 2 and 22 | Explosion protection: regulations: EN IEC 60079-0 | Operating voltage: 24 VDC -15 % / +10 % | PFH value: 2.50 x 10⁻⁹ | PIN 2: Y2 Safety output 2 red | Hysteresis (Switching distance), maximum: 0.7 | ISO thread of the sensor: M18 | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Operating voltage, minimum: 20.4 | Current, Utilisation category DC-12: 0.05 | Note (LED switching conditions display): Multi-coloured LED: Green, Red, Yellow | PIN 1: A1 Ue Brown | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | Scope of delivery of mounting material: 2x nuts M18 x 1 | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | PIN 7: Signalling output Grey | Category: 4 | Recommendation (actuator): CST 180-2 | Operating current: 1,000 | TOL_VOLT_OPERAT_DC_MAX: 10 | Tightening torque of nuts, maximum: 3 | Switching frequency, approx.: 3 | PIN 6: X2 Safety input 2 White | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Number of cable wires: 7 | Number of semi-conductor outputs with signaling function: 1 | Active area: Glass-fibre, reinforced thermoplastic | Length of cable: 10 | Duration of risk, maximum: 30 | Voltage type: DC | Number of series-wiring of sensors: 16 | Repeat accuracy R: 0.2 | PIN 4: Y1 Safety output 1 Black | Absicherung des Sicherheitsausganges: short-circuit proof, p-type | Overvoltage category: 3 | Explosion protection zones: 22 | Traceparts, product ID: 33-22052019-077908 | Electrical fuse rating: short-circuit proof, p-type | Switch distance, typical: 8 | Reaction time, maximum: 30 | Performance Level, up to: e |