Products Introduction

Schmersal AZM201Z-I2-ST2-T-1P2PW-A (Order No: 103013489) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +60 °C;...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM201Z-I2-ST2-T-1P2PW-A, Order No: 103013489. Competitive pricing, fast quotation.

Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.

More Schmersal Products from Glorient

In addition to AZM201Z-I2-ST2-T-1P2PW-A, Glorient also supplies:

SLC440-ER-1210-14-01 Order No: 101216628
EDP40.VGN Order No: 101006179
SVE1/SR/142WS/BR-24VDC Order No: 103013876
ZSM 476-11-M1-230 Order No: 101217256
EDLWS/101 Order No: 101191264
PT-440-ER-1370 Order No: 103033965
ZQ 900 ST-AS Order No: 101214847
EX-Z4V10H 355-02Z-3G/D Order No: 101191220
ENAF15.044 Order No: 101194090
TS 232-02H Order No: 151214391
SEK101.S Order No: 101023633
ASSB-4P-SW-V1 Order No: 103001618
#TRA.NPN BC 817-40 SOT-23 Order No: 101183734
SHGV/ESS21S2/180/103 Order No: 101205908
HEBEL L KPL. AUSF. YT MS-ROLLE Order No: 101064610
PS116-Z11-ST-K280 Order No: 103015340
E-KB9.1SW/L00841309 Order No: 101218174
Z1R 235-02Z-M20 Order No: 151169229
BPS 303 Order No: 101117076
ESS21S1/EKM205 Order No: 103050363
SHGV/L01/203+BOW Order No: 101198293
SLC440-ER-1770-14-01 Order No: 103009251
SESR13.022 Order No: 101019897
ESS21S1/EKM55 Order No: 103050155
PS216L-Z11R-M16-K210-U2 Order No: 103030673
EX-RDTWS/501D Order No: 103000624
BN 31-RZ-2730 2,0M Order No: 103011560
BDF200-SD-NHK-SWS20-LTBU-LTRD Order No: 103050608
DREHHEBELVORSATZ Y VERZAHNT Order No: 101119398
SHGV/B01/200+BOW Order No: 101218838

Related Guides

Gross weight593 g
Net weight593 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078519 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesUKCA
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661493329
Mission time20
TerminationConnector M12, 8-pole
Mechanical lifetime, minimum1,000,000
Length of sensor50 mm
Width of sensor40 mm
Height of sensor220 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
Actuating speed, maximum0.2 m/s
NoteTorx T10
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersOperating current: 1,200 | Coding: Individual coding, multiple teaching | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Wiring capacitance: 50 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Tightening torque of the fastening screws for the housing cover: 0.7 ... 1 Nm (Torx T10) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Category: 2 | Test pulse duration, maximum: 5 | Allowed type of cable: solid single-wire, solid multi-wire, flexible | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): AZ/AZM201-B1 | Current consumption with magnet ON, average : 200 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | External wire and device fuse rating: 2 A gG (Connector M12, 8-pole) | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole | PFH value: 1.00 x 10⁻⁸ | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | PFD value: 8.90 x 10⁻⁴ | Performance Level, up to: d | Classification ZVEI CB24I, Sink: C1 | Fuse rating to UL 508, maximum: 4 | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Tightening torque of the fixing screws, maximum: 8 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | CADENAS: Yes | Latching force: 30 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Safety Integrity Level (SIL), suitable for applications in: 2 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Connection type: Screw terminals, Connector M12, 8-pole, Spring pulley connection | TOL_VOLT_OPERAT_DC_MAX: 10 | Current consumption with magnet ON, peak: 700 mA / 100 ms | Reaction time, switching off safety outputs via actuator, maximum: 100 | Wire cross-section: 23 ... 15 AWG | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Manual release: Yes | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Degree of protection: IP66, IP67 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Tightening torque of the fastening screws for the housing cover, minimum: 0.7 | Test pulse interval, typical: 1,000 | ACE reference article number: 11930833 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5