Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM 161SK-12/12RIAT-024G-B6R

Schmersal AZM 161SK-12/12RIAT-024G-B6R

Model: AZM 161SK-12/12RIAT-024G-B6R
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 16 views

Products Introduction

Schmersal AZM 161SK-12/12RIAT-024G-B6R (Order No: 103014449) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient temper...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM 161SK-12/12RIAT-024G-B6R, Order No: 103014449. Competitive pricing, fast quotation.

Schmersal AZM 161SK-12/12RIAT-024G-B6R - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM 161SK-12/12RIAT-024G-B6R is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078487 °C
Ambient temperature, minimum-30 °C
StandardsEN IEC 60947-5-1
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661496399
Mission time20
TerminationScrew terminals
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching elementNO contact, NC contact
Switching principleslow action, positive break NC contact
Width of sensor130 mm
Thermal test current6 A
Cable section, maximum1.5 mm²
Height of sensor90 mm
Material of the contacts, electricalSilver
Utilisation category DC-1324 VDC / 2.5 A
Max. fuse rating6 A gG D-fuse to DIN EN 60269-1
Utilisation category AC-15230 VAC / 4 A
Maximum switching frequency1,000 Hz
Cable section, minimum0.25 mm²
Number of safety contacts3 / 4 / 5
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteAll indications including the conductor ferrules.
Number of auxiliary contacts1 / 2
TracepartsYes
Storage and transport temperature-25 ... +85 °C
Scope of deliveryThe actuator is included in the scope of delivery
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
MountingScrews
Protection classII
Other ParametersVoltage, Utilisation category DC-13: 24 | Voltage, Utilisation category AC-15: 230 | Test pulse interval, minimum: 50 | Number of actuating directions: 3 | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Integral system diagnostics, status: Yes | Actuating radius, minimum: 95 | Power to lock: Yes | Working principle: electromechanical | Emergency exit: Yes | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | Latching force: 30 N | CADENAS: Yes | Positive break travel: 10 | Current, Utilisation category DC-13: 4 | Material of the actuator: Stainless steel | Type of the fixing screws: 3x M6 | Positive break force, minimum: 20 | Allowed type of cable: solid single-wire | Coding: Individual coding | Current, Utilisation category AC-15: 4 | Electrical power consumption, maximum: 10 | Coding level according to EN ISO 14119: High | Note (Emergency exit): In case of emergency actuation from within the hazardous area | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Manual release: Yes | Tightening torque of electrical connection, maximum: 0.5 | Note (Manual release): For maintenance, installation, etc. | Category: 3 | Actuating play in direction of actuation: 5.5 | Note (applications): removable guard | Tightening torque of the fastening screws for the housing cover: 0.6 | Positive break force per NC contact, minimum: 10 | Permissible installation altitude above sea level, maximum: 2,000 | Tightening torque of electrical connection, minimum: 0.4 | Cable entry: 2 x M16 x 1.5

More Schmersal Products from Glorient

In addition to AZM 161SK-12/12RIAT-024G-B6R, Glorient also supplies:

BNS 250-12ZG 10,0M Order No: 101150803
NDAN6GR/250° Order No: 103004129
SHGV/ESS21S2/208/103 Order No: 101205736
G150-300T02/02Y-1520-1 Order No: 101169301
NDLWS/SYM-D635 Order No: 101191272
AZM201Z-I2-CC-T-1P2PW Order No: 103013487
CSS 12-34-V-D-M-ST Order No: 101181065
SHGV/LD1/100/40+BOF/HIS.1 Order No: 103050945
SVE1/71-3Ö-24VDC Order No: 101197609
TK 016-12Y Order No: 101054875
DPNJ55RT Order No: 101006970
PS216-Z11R-M16-K250-U6 Order No: 103033765
SMS 4-690-1050 Order No: 103040002
MKTE52/2X401-2949-1 Order No: 103016111
SHGV/B01/103+BOF/HIS2 Order No: 101198320
EX-SLG440-ER-0800-03-H Order No: 103047626
AZM150SK-02/02RIA-024-B6L Order No: 153032217
SE-RC BETAETIGUNGSNOCKEN Order No: 101179992
TZFWN24VDC Order No: 131017670
G88102201 Order No: 103010212
SEIL KPL. TQ 200 Order No: 101114353
SVM1/107-10/216/A Order No: 103044577
ZS 336-11Z-M20 Order No: 151156136
AZ/AZM201-B30-LTAG1P20 Order No: 103027215
WKTB32 Order No: 101019514
AZ 16-03ZIB1-M20 Order No: 101150637
AV15LKIP41X30U-GB215 Order No: 103042224

Related Guides

Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078487 °C
Ambient temperature, minimum-30 °C
StandardsEN IEC 60947-5-1
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661496399
Mission time20
TerminationScrew terminals
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching elementNO contact, NC contact
Switching principleslow action, positive break NC contact
Width of sensor130 mm
Thermal test current6 A
Cable section, maximum1.5 mm²
Height of sensor90 mm
Material of the contacts, electricalSilver
Utilisation category DC-1324 VDC / 2.5 A
Max. fuse rating6 A gG D-fuse to DIN EN 60269-1
Utilisation category AC-15230 VAC / 4 A
Maximum switching frequency1,000 Hz
Cable section, minimum0.25 mm²
Number of safety contacts3 / 4 / 5
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteAll indications including the conductor ferrules.
Number of auxiliary contacts1 / 2
TracepartsYes
Storage and transport temperature-25 ... +85 °C
Scope of deliveryThe actuator is included in the scope of delivery
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
MountingScrews
Protection classII
Other ParametersVoltage, Utilisation category DC-13: 24 | Voltage, Utilisation category AC-15: 230 | Test pulse interval, minimum: 50 | Number of actuating directions: 3 | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Integral system diagnostics, status: Yes | Actuating radius, minimum: 95 | Power to lock: Yes | Working principle: electromechanical | Emergency exit: Yes | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | Latching force: 30 N | CADENAS: Yes | Positive break travel: 10 | Current, Utilisation category DC-13: 4 | Material of the actuator: Stainless steel | Type of the fixing screws: 3x M6 | Positive break force, minimum: 20 | Allowed type of cable: solid single-wire | Coding: Individual coding | Current, Utilisation category AC-15: 4 | Electrical power consumption, maximum: 10 | Coding level according to EN ISO 14119: High | Note (Emergency exit): In case of emergency actuation from within the hazardous area | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Manual release: Yes | Tightening torque of electrical connection, maximum: 0.5 | Note (Manual release): For maintenance, installation, etc. | Category: 3 | Actuating play in direction of actuation: 5.5 | Note (applications): removable guard | Tightening torque of the fastening screws for the housing cover: 0.6 | Positive break force per NC contact, minimum: 10 | Permissible installation altitude above sea level, maximum: 2,000 | Tightening torque of electrical connection, minimum: 0.4 | Cable entry: 2 x M16 x 1.5