Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM 170CC-01/02ZRK-2405/2656 24VAC/DC

Schmersal AZM 170CC-01/02ZRK-2405/2656 24VAC/DC

Model: AZM 170CC-01/02ZRK-2405/2656 24VAC/DC
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 14 views

Products Introduction

Schmersal AZM 170CC-01/02ZRK-2405/2656 24VAC/DC (Order No: 103025491) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambie...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM 170CC-01/02ZRK-2405/2656 24VAC/DC, Order No: 103025491. Competitive pricing, fast quotation.

Schmersal AZM 170CC-01/02ZRK-2405/2656 24VAC/DC - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM 170CC-01/02ZRK-2405/2656 24VAC/DC is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078499 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-1
IP Degree of protectionIP67
CertificatescULus, CCC
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661513409
Mission time20
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching elementMagnet: 1 NC contact / Actuator: 2 NC contacts
Switching principleslow action, positive break NC contact
Width of sensor122 mm
Cable section, maximum1 mm²
Height of sensor100.5 mm
Material of the contacts, electricalSilver
Max. fuse rating6 A gG D-fuse
Maximum switching frequency1,000 Hz
Cable section, minimum0.75 mm²
Number of safety contacts3
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteTorx T10
Number of auxiliary contacts1 / 2
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
MountingScrews
Note (General)(-2656) Wiring for separate monitoring of the magnet
Degree of pollution3
Protection classII
Other ParametersOvervoltage category: III | Voltage, Utilisation category DC-13: 24 | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Test pulse interval, minimum: 50 | Electrical power consumption, maximum: 12 | Power to unlock: Yes | Note (Switching element): Change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges | Test pulse duration, maximum: 5 | Wire cross-section, minimum: 20 | Note (Relative humidity): non-condensing | Positive break force per NC contact, minimum: 8.5 | Coding level according to EN ISO 14119: Low | Latching force: 5 / 30 N | Cable cross-section of the cable glands, minimum: 4 | Working principle: electromechanical | Emergency exit: Yes | Protection class (Operating resource): 2 | Wire cross-section, maximum: 18 | Magnet switch-on time: 100 | Type of the fixing screws: 2x M4 | Current, Utilisation category DC-13: 4 | Positive break travel: 11 | Allowed type of cable: solid single-wire | Increased latching force: Yes | Cable entry: 1 x M20 x 1,5 | Unlocking: Rotating unlatcher | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Terminal (mechanical): cage terminals | Performance Level, up to: c | Operating current: 4,000 | Cable cross-section of the cable glands, maximum: 10 | Note (Emergency exit): For cases of danger | Category: 3 | Number of actuating directions: 2 | Note (applications): removable guard | Positive break force, minimum: 17 | Permissible installation altitude above sea level, maximum: 2,000 | Tightening torque of the fastening screws for the housing cover, minimum: 0.7

More Schmersal Products from Glorient

In addition to AZM 170CC-01/02ZRK-2405/2656 24VAC/DC, Glorient also supplies:

DMNHSW Order No: 101006899
PS116-T11-LR200-N202 Order No: 103027882
Z4VH 336-11Z-ST-RMS Order No: 151161514
T. 471-02/02Y Order No: 101061077
EX-SHGV/R01/216+BO-2G/D Order No: 103000678
AZM201Z-ST2-T-1P2PW Order No: 103013909
SHGV/EKM132 Order No: 103010239
SHGV-SR/GN Order No: 101160197
PS226-Z11-J203 Order No: 103046767
AV18LHKX11.5U-GB215 Order No: 103028168
BNS 36-02ZG-L 10,0M Order No: 103012611
PS216-T12-K250 Order No: 103015041
TS 064-21Y Order No: 101057470
AV25LKX20U-GB215 Order No: 103016462
SVM1/88-10/138/E Order No: 101215442
TZ/CORF/HIS.2 Order No: 101025340
RDLMWS Order No: 101188167
AZM 415-11/02ZPKFE 24VAC/DC Order No: 101196227
SMS 4-900-1000-0362 Order No: 103047390
SHGV/B01/217+BOW Order No: 101198413
AZ 15 ZVRK-M20-1637 Order No: 101173064
TK4 235-02Z Order No: 101091566
AZ 16-12ZI-STR-B6L-M16 Order No: 103011716
SVM1/71-6/121/E Order No: 101213583
SHGV-Z/B01/120+BOF/HIS2 Order No: 103044551
Z4VH 336-11Z-M20-1058 Order No: 151161685
DRNSW Order No: 101006985
SHGV/B01/123+BOW Order No: 101198391

Related Guides

Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078499 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-1
IP Degree of protectionIP67
CertificatescULus, CCC
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661513409
Mission time20
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching elementMagnet: 1 NC contact / Actuator: 2 NC contacts
Switching principleslow action, positive break NC contact
Width of sensor122 mm
Cable section, maximum1 mm²
Height of sensor100.5 mm
Material of the contacts, electricalSilver
Max. fuse rating6 A gG D-fuse
Maximum switching frequency1,000 Hz
Cable section, minimum0.75 mm²
Number of safety contacts3
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteTorx T10
Number of auxiliary contacts1 / 2
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
MountingScrews
Note (General)(-2656) Wiring for separate monitoring of the magnet
Degree of pollution3
Protection classII
Other ParametersOvervoltage category: III | Voltage, Utilisation category DC-13: 24 | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Test pulse interval, minimum: 50 | Electrical power consumption, maximum: 12 | Power to unlock: Yes | Note (Switching element): Change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges | Test pulse duration, maximum: 5 | Wire cross-section, minimum: 20 | Note (Relative humidity): non-condensing | Positive break force per NC contact, minimum: 8.5 | Coding level according to EN ISO 14119: Low | Latching force: 5 / 30 N | Cable cross-section of the cable glands, minimum: 4 | Working principle: electromechanical | Emergency exit: Yes | Protection class (Operating resource): 2 | Wire cross-section, maximum: 18 | Magnet switch-on time: 100 | Type of the fixing screws: 2x M4 | Current, Utilisation category DC-13: 4 | Positive break travel: 11 | Allowed type of cable: solid single-wire | Increased latching force: Yes | Cable entry: 1 x M20 x 1,5 | Unlocking: Rotating unlatcher | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Terminal (mechanical): cage terminals | Performance Level, up to: c | Operating current: 4,000 | Cable cross-section of the cable glands, maximum: 10 | Note (Emergency exit): For cases of danger | Category: 3 | Number of actuating directions: 2 | Note (applications): removable guard | Positive break force, minimum: 17 | Permissible installation altitude above sea level, maximum: 2,000 | Tightening torque of the fastening screws for the housing cover, minimum: 0.7