Schmersal RSS16-I1-D-CC-2982 (Order No: 103025819) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: 2 x M5, Cylinder head screw; Ambi...
Glorient offers competitive supply of Schmersal RSS16-I1-D-CC-2982, Order No: 103025819. Competitive pricing, fast quotation.
Schmersal RSS16-I1-D-CC-2982 - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal RSS16-I1-D-CC-2982 is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 250 g |
| Net weight | 250 g |
| Ambient temperature | -28 ... +70 °C |
| Ambient temperature, maximum | +70 °C |
| Ambient temperature, minimum | -30 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP67 |
| Certificates | TÜV, cULus, FCC, IC, ANATEL |
| Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661514437 |
| Mission time | 20 |
| Termination | Spring pulley connection |
| Length of sensor | 91 mm |
| Width of sensor | 52 mm |
| Cable section, maximum | 1.5 mm² |
| Height of sensor | 30 mm |
| Utilisation category DC-13 | 24 VDC / 1 A |
| Cable section, minimum | 0.25 mm² |
| Required rated short-circuit current | 100 A |
| Traceparts | Yes |
| Housing construction form | Block |
| Safety functions | Yes |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -30 °C |
| Mounting | 2 x M5, Cylinder head screw |
| Degree of pollution | 3 |
| Other Parameters | Number of fail-safe digital outputs: 2 | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Actuating panels: from head | Operating current: 2,100 | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Operating current, minimum: 0.5 | Hysteresis (Switching distance), maximum: 2 | Cable section: 0.25 mm² ... 1.5 mm² | Note (LED switching conditions display): LED green: Supply voltage | Series-wiring: Yes | Output current, (fail-safe output), maximum: 1 | Cross-circuit detection: Yes | Current, Utilisation category DC-13: 1 | Switching frequency, maximum: 1 | Voltage, Utilisation category DC-12: 24 | Recommended safety switchgear: SRB-E-301ST | Restistance to shock: 30 g / 11 ms | Utilisation category DC-12: 24_1 | Relative humidity, maximum: 93 | PFD value: 1.50 x 10⁻⁵ | Design of control elements: p-type | Diagnostic output: Yes | Operating voltage: 24 VDC -15 % / +10 % | Working principle: RFID | CADENAS: Yes | Rated operating voltage, minimum: 20.4 VDC | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Rated operating voltage, maximum: 26.4 VDC | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Active area: front side | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | Installation conditions (mechanical): not flush | Reaction time, maximum: 100 | Category: 4 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Tightening torque of the fixing screws: 2 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Coding: Individual coding | TOL_VOLT_OPERAT_DC_MAX: 10 | Number of LEDs: 2 | Duration of risk, maximum: 200 | Coding level according to EN ISO 14119: High | Cascadable: Yes | Cable entry: 4 x M16 x 1,5 | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Current consumption of the safety inputs: 5 | Number of semi-conductor outputs with signaling function: 1 | Time to readiness, maximum: 2,000 | Rated operating current (safety outputs): 1,000 | Rated operating voltage: 24 | Voltage type: DC | Interfering radiation: IEC 61000-6-4 | Recommendation (actuator): RST16-1 | Permissible installation altitude above sea level, maximum: 2,000 | Switch distance, typical: 15 | Absicherung des Sicherheitsausganges: short-circuit proof, p-type | Overvoltage category: 3 | Performance Level, up to: e | PFH value: 6.30 x 10⁻¹¹ |
In addition to RSS16-I1-D-CC-2982, Glorient also supplies:
| Gross weight | 250 g |
| Net weight | 250 g |
| Ambient temperature | -28 ... +70 °C |
| Ambient temperature, maximum | +70 °C |
| Ambient temperature, minimum | -30 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP67 |
| Certificates | TÜV, cULus, FCC, IC, ANATEL |
| Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661514437 |
| Mission time | 20 |
| Termination | Spring pulley connection |
| Length of sensor | 91 mm |
| Width of sensor | 52 mm |
| Cable section, maximum | 1.5 mm² |
| Height of sensor | 30 mm |
| Utilisation category DC-13 | 24 VDC / 1 A |
| Cable section, minimum | 0.25 mm² |
| Required rated short-circuit current | 100 A |
| Traceparts | Yes |
| Housing construction form | Block |
| Safety functions | Yes |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -30 °C |
| Mounting | 2 x M5, Cylinder head screw |
| Degree of pollution | 3 |
| Other Parameters | Number of fail-safe digital outputs: 2 | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Actuating panels: from head | Operating current: 2,100 | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Operating current, minimum: 0.5 | Hysteresis (Switching distance), maximum: 2 | Cable section: 0.25 mm² ... 1.5 mm² | Note (LED switching conditions display): LED green: Supply voltage | Series-wiring: Yes | Output current, (fail-safe output), maximum: 1 | Cross-circuit detection: Yes | Current, Utilisation category DC-13: 1 | Switching frequency, maximum: 1 | Voltage, Utilisation category DC-12: 24 | Recommended safety switchgear: SRB-E-301ST | Restistance to shock: 30 g / 11 ms | Utilisation category DC-12: 24_1 | Relative humidity, maximum: 93 | PFD value: 1.50 x 10⁻⁵ | Design of control elements: p-type | Diagnostic output: Yes | Operating voltage: 24 VDC -15 % / +10 % | Working principle: RFID | CADENAS: Yes | Rated operating voltage, minimum: 20.4 VDC | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Rated operating voltage, maximum: 26.4 VDC | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Active area: front side | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | Installation conditions (mechanical): not flush | Reaction time, maximum: 100 | Category: 4 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Tightening torque of the fixing screws: 2 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Coding: Individual coding | TOL_VOLT_OPERAT_DC_MAX: 10 | Number of LEDs: 2 | Duration of risk, maximum: 200 | Coding level according to EN ISO 14119: High | Cascadable: Yes | Cable entry: 4 x M16 x 1,5 | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Current consumption of the safety inputs: 5 | Number of semi-conductor outputs with signaling function: 1 | Time to readiness, maximum: 2,000 | Rated operating current (safety outputs): 1,000 | Rated operating voltage: 24 | Voltage type: DC | Interfering radiation: IEC 61000-6-4 | Recommendation (actuator): RST16-1 | Permissible installation altitude above sea level, maximum: 2,000 | Switch distance, typical: 15 | Absicherung des Sicherheitsausganges: short-circuit proof, p-type | Overvoltage category: 3 | Performance Level, up to: e | PFH value: 6.30 x 10⁻¹¹ |