Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

BDF200-SD-NHK-LT-LT-LT-2875

Schmersal BDF200-SD-NHK-LT-LT-LT-2875

Model: BDF200-SD-NHK-LT-LT-LT-2875
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 18 views

Products Introduction

Schmersal BDF200-SD-NHK-LT-LT-LT-2875 (Order No: 103025848) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: interior mounting holes;...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal BDF200-SD-NHK-LT-LT-LT-2875, Order No: 103025848. Competitive pricing, fast quotation.

Schmersal BDF200-SD-NHK-LT-LT-LT-2875 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal BDF200-SD-NHK-LT-LT-LT-2875 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight280 g
Net weight280 g
Ambient temperature-25 ... +65 °C
Ambient temperature, maximum+65 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 61508
IP Degree of protectionIP65
CertificatesTÜV, cULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661514598
Mission time20
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Mountinginterior mounting holes
Degree of pollution3
Protection classIII
Other ParametersPFH value: 2.89 x 10⁻¹⁰ | Reaction time, maximum: 50 | Operation current: 100 | Number of fail-safe digital outputs: 2 | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Positions used, position 1: Emergency stop, with protective collar | PIN 3: A2 GND | Width: 40 | Design of control elements: short-circuit proof, p-type | Height: 69 | Switching thresholds: −3 V … 5 V (Low) | Traceparts, product ID: 69-13072010-095143 | Duration of risk, maximum: 100 | Positions used, position 4: Illuminated pushbutton, color exchangeable | Mechanical lifetime, Command devices: 1,000,000 | Switching frequency, maximum: 1 | Operating current: 600 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Classification ZVEI CB24I, Source: C1 | PIN 2: X1 Safety input 1 | Serial diagnostics: Yes | Wiring capacitance: 50 | Classification ZVEI CB24I, Sink: C1 | Rated operating voltage: 24 VDC −15 % / +10 % | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Positions used, position 2: Illuminated pushbutton, color exchangeable | PIN 5: OUT serial diagnostic output | Voltage, Utilisation category DC-12: 24 | Voltage, Utilisation category DC-13: 24 | Category: 4 | TOL_VOLT_OPERAT_DC_MAX: 10 | Mechanical lifetime, Emergency-Stop button: 100,000 | Note (PFH-value): up to max. 5,000 switching cycles/year | PIN 4: Y1 Safety output 1 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Positions used, position 3: Illuminated pushbutton; color exchangeable | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Test pulse duration, maximum: 1 | Designation, Serial diagnostic SD: OUT | Time to readiness, maximum: 2,000 | Field box interface: Yes | PIN 7: Y2 Safety output 2 | Voltage type: DC | Current, Utilisation category DC-13: 0.25 | PIN 1: A1 Supply voltage UB | Note (Ordering data): Notice: see ordering code | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Current, Utilisation category DC-12: 0.25 | Permissible installation altitude above sea level, maximum: 2,000 | PIN 8: IN serial diagnostic input | Climatic stress: DIN EN 60068 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Test pulse interval, minimum: 100 | Designation, Safety outputs: Y1 and Y2 | Depth: 233.5 | Performance Level, up to: e | Type of the fixing screws: 2x M5

More Schmersal Products from Glorient

In addition to BDF200-SD-NHK-LT-LT-LT-2875, Glorient also supplies:

BDF200-ST1-AS-B-B-LTGN-LTBU Order No: 103003634
SMS 4-300-1500 Order No: 103015538
T4V7H 335-03Z-2138 Order No: 151196214
AZ 15 ZVRK-M16-2433 Order No: 101169227
MV8H 330-11Y-1172 Order No: 131158902
SLG440AS-E-0900-04 Order No: 103007559
LEV-U14-B50-150-RVA Order No: 103012919
BNS 33-12Z-2363 6,0M Order No: 101153904
M2S 330-11Y-AUNI-M20 Order No: 131150209
SHGV/LD1/100/38+BO Order No: 101210782
AZM150SK-02/02RIAT-024-B6L Order No: 153032222
NDTGR/GR Order No: 101163568
EDP55GN Order No: 101006305
SHGV/R01/131+BOW Order No: 103015580
Z4V. 335-02Z-ST Order No: 151172293
M 660-11-K-Y GB 153 Order No: 101093332
T1R 256-11Z Order No: 101112710
ZV1H 235-11Z-ST-1637 Order No: 153002148
SMS4-750-975 Order No: 103005811
SVE2/213/213-24VDC Order No: 101212566
EDR35BL Order No: 101006355
BNS-B20-12Z-H-2619 5,0M Order No: 101195981
EDLWS/301 Order No: 101189734
BETAETIGER AZ 15/16-B6 KPL. Order No: 101137434
TASTENUNTERTEIL EX-RDP-3 Order No: 101188520
M1R 660-11-K-Y 1,0M -1537 Order No: 101091870
M 630-11-2-A30-II Order No: 151146140
BN 20-2RZ-M16 Order No: 101172893
ZS 235-11Z-ST-3142-2 Order No: 153051285

Related Guides

Gross weight280 g
Net weight280 g
Ambient temperature-25 ... +65 °C
Ambient temperature, maximum+65 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 61508
IP Degree of protectionIP65
CertificatesTÜV, cULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661514598
Mission time20
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Mountinginterior mounting holes
Degree of pollution3
Protection classIII
Other ParametersPFH value: 2.89 x 10⁻¹⁰ | Reaction time, maximum: 50 | Operation current: 100 | Number of fail-safe digital outputs: 2 | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Positions used, position 1: Emergency stop, with protective collar | PIN 3: A2 GND | Width: 40 | Design of control elements: short-circuit proof, p-type | Height: 69 | Switching thresholds: −3 V … 5 V (Low) | Traceparts, product ID: 69-13072010-095143 | Duration of risk, maximum: 100 | Positions used, position 4: Illuminated pushbutton, color exchangeable | Mechanical lifetime, Command devices: 1,000,000 | Switching frequency, maximum: 1 | Operating current: 600 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Classification ZVEI CB24I, Source: C1 | PIN 2: X1 Safety input 1 | Serial diagnostics: Yes | Wiring capacitance: 50 | Classification ZVEI CB24I, Sink: C1 | Rated operating voltage: 24 VDC −15 % / +10 % | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Positions used, position 2: Illuminated pushbutton, color exchangeable | PIN 5: OUT serial diagnostic output | Voltage, Utilisation category DC-12: 24 | Voltage, Utilisation category DC-13: 24 | Category: 4 | TOL_VOLT_OPERAT_DC_MAX: 10 | Mechanical lifetime, Emergency-Stop button: 100,000 | Note (PFH-value): up to max. 5,000 switching cycles/year | PIN 4: Y1 Safety output 1 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Positions used, position 3: Illuminated pushbutton; color exchangeable | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Test pulse duration, maximum: 1 | Designation, Serial diagnostic SD: OUT | Time to readiness, maximum: 2,000 | Field box interface: Yes | PIN 7: Y2 Safety output 2 | Voltage type: DC | Current, Utilisation category DC-13: 0.25 | PIN 1: A1 Supply voltage UB | Note (Ordering data): Notice: see ordering code | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Current, Utilisation category DC-12: 0.25 | Permissible installation altitude above sea level, maximum: 2,000 | PIN 8: IN serial diagnostic input | Climatic stress: DIN EN 60068 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Test pulse interval, minimum: 100 | Designation, Safety outputs: Y1 and Y2 | Depth: 233.5 | Performance Level, up to: e | Type of the fixing screws: 2x M5