Schmersal AZM201Z-ST2-T-SD2P (Order No: 103032731) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +60 °C; Ambie...
Glorient offers competitive supply of Schmersal AZM201Z-ST2-T-SD2P, Order No: 103032731. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to AZM201Z-ST2-T-SD2P, Glorient also supplies:
| Gross weight | 562 g |
| Net weight | 562 g |
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000078519 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP66 |
| Certificates | UKCA |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 4030661529431 |
| Mission time | 20 |
| Termination | Connector M12, 8-pole |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 50 mm |
| Width of sensor | 40 mm |
| Height of sensor | 220 mm |
| Utilisation category DC-13 | 24 VDC / 0.05 A |
| Required rated short-circuit current | 100 A |
| Actuating speed, maximum | 0.2 m/s |
| Note | Torx T10 |
| Traceparts | Yes |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Degree of pollution | 3 |
| Protection class | III |
| Other Parameters | Operating current: 1,200 | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Wiring capacitance: 50 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Power to unlock: Yes | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole | Tightening torque of the fastening screws for the housing cover: 0.7 ... 1 Nm (Torx T10) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Test pulse duration, maximum: 5 | Allowed type of cable: solid single-wire, solid multi-wire, flexible | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): AZ/AZM201-B1 | Current consumption with magnet ON, average : 200 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | PFH value: 1.00 x 10⁻⁸ | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | PFD value: 8.90 x 10⁻⁴ | Serial diagnostics: Yes | External wire and device fuse rating: 2 A gG | Coding: Universal coding | Performance Level, up to: d | Classification ZVEI CB24I, Sink: C1 | Fuse rating to UL 508, maximum: 4 | Test pulse interval, minimum: 40 | Number of series-wiring of sensors: 31 | Magnet switch-on time: 100 | Tightening torque of the fixing screws, maximum: 8 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | CADENAS: Yes | Latching force: 30 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT serial diagnostic output | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Rated operating current (safety outputs): 250 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Connection type: Screw terminals, Connector M12, 8-pole, Spring pulley connection | TOL_VOLT_OPERAT_DC_MAX: 10 | Current consumption with magnet ON, peak: 700 mA / 100 ms | Reaction time, switching off safety outputs via actuator, maximum: 100 | Wire cross-section: 23 ... 15 AWG | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Frequency band RFID: 125 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Designation, Serial diagnostic SD: OUT | Manual release: Yes | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Safety Integrity Level (SIL), suitable for applications in: 2 | Length of sensor chain, maximum: 200 | Current, Utilisation category DC-13: 0.25 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | PIN 8: IN serial diagnostic input | Degree of protection: IP66, IP67 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Tightening torque of the fastening screws for the housing cover, minimum: 0.7 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Operation current: 150 |