Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM40Z-I2-ST-1P2P

Schmersal AZM40Z-I2-ST-1P2P

Model: AZM40Z-I2-ST-1P2P
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 16 views

Products Introduction

Schmersal AZM40Z-I2-ST-1P2P (Order No: 103034189) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: mounting holes countersink; Ambie...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM40Z-I2-ST-1P2P, Order No: 103034189. Competitive pricing, fast quotation.

Schmersal AZM40Z-I2-ST-1P2P - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM40Z-I2-ST-1P2P is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight300 g
Net weight300 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, FCC, IC, UKCA, ANATEL
Housing materialLight alloy die cast and plastic (glass-fibre reinforced thermoplastic)
EAN (European Article Number)4030661535142
Mission time20
Length of sensor119.5 mm
Width of sensor40 mm
Height of sensor20 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
Actuating speed, maximum0.5 m/s
NoteObserve the maximum tightening torque of the fixing screws used.
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-40 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Mountingmounting holes countersink
Degree of pollution3
Protection classIII
Other ParametersOperating current: 1,200 | Coding: Individual coding, multiple teaching | Mechanical lifetime, actuator cycles: 500,000 | ACE reference article number: 11931058 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Rated operating voltage: 24 VDC - 15 % / + 10 % (stabilised PELV) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Category: 2 | Test pulse duration, maximum: 5 | Note (Manual release): Manual release from side | Interlocking principle: bistable | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Property class: 8.8 / 80 | Integral system diagnostics, status: Yes | Current consumption at 24V, maximum: 15 | Mechanical lifetime, locking cycles: 1,000,000 | Note (Mechanical lifetime): from device version V2 (V1 = 200.000 actuator cycles) | Series-wiring: Yes | Cross-circuit detection: Yes | Installation conditions (mechanical): arbitrarily | PFH value: 3.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | REVIEW_ELEC_WIRING_GENERAL_GPV: 1000263857 | Current consumption at 24 V: 10 ... 15 mA | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Recommendation (actuator): AZM40-B1 | External wire and device fuse rating: 2 A gG | Design of control elements: OSSD, short-circuit proof, p-type | Classification ZVEI CB24I, Sink: C1 | PFD value: 8.90 x 10⁻⁵ | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Working principle: RFID | Transmitter output RFID, maximum: -6 | CADENAS: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Tightening torque of the fixing screws: 4 ... 6 Nm | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Safety Integrity Level (SIL), suitable for applications in: 2 | Current, Utilisation category DC-13: 0.05 | Switching frequency, maximum: 0.25 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Tightening torque of the fixing screws, maximum: 6 | Current consumption magnet at switching moment, peak: 600 mA / 100 ms | TOL_VOLT_OPERAT_DC_MAX: 10 | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Unlocking: Rotating unlatcher | Duration of risk, maximum: 200 | Performance Level, up to: e | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Current consumption at 24V, minimum: 10 | TOL_VOLT_OPERAT_DC_MIN: -15 | Latching force: 40 N | Manual release: Yes | Actuating angle: 180 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Note (Latch force): +/- 25% | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Designation, Safety outputs: Y1 and Y2 | Tightening torque of the fixing screws, minimum: 4 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Type of the fixing screws: 2x M5

More Schmersal Products from Glorient

In addition to AZM40Z-I2-ST-1P2P, Glorient also supplies:

AZ/AZM201-B1-RTP0 Order No: 103013495
SLC445-ER-0170-14-01 Order No: 103005386
ZV1H 236-02Z-M20 Order No: 151154488
SVE2/160/160-3Ö-24VDC Order No: 103039504
EF03.1-20ST Order No: 103012956
PS226-T02-K230 Order No: 103015084
BN 310-01Z 2,0M Order No: 103003342
SLC440AS-ER-1690-30 Order No: 103007544
SET AZ 15ZVRK-ST-B1-2864-1 Order No: 103008684
GS75102192-1 Order No: 103010180
TV14H 235-11Z-M20 Order No: 151152883
SHGV/SR/RD1/113/53RT/RT+BOW Order No: 103035182
TR 336-20Z-RMS Order No: 151134570
SEPG05.3.2.1.22/95 Order No: 101172763
T3K 236-11Z-M20-1297 Order No: 151169111
SHGV/D01/200+BOW Order No: 103040159
MZM 100 ST2-1P2PW-A Order No: 101199623
TD 250-02Z-1276-2-2512 Order No: 101195963
EF303S.3 Order No: 101006586
DTNGB/MU/FS30 Order No: 101194483
EX-Z1R 235-11Z-3D Order No: 101195079
SVM1/78-10/128/E Order No: 103010060
BNS-B20-12ZG-R Order No: 101186265
ZQ215AL-02 Order No: 103044936
SLC440-ER-0410-14 Order No: 101216600
EX-T1K 335-03Z-RMS-3G/D Order No: 151211757
TR 236-02Z-RVA Order No: 151151269
AZ 415-STS30-08 Order No: 101176938

Related Guides

Gross weight300 g
Net weight300 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, FCC, IC, UKCA, ANATEL
Housing materialLight alloy die cast and plastic (glass-fibre reinforced thermoplastic)
EAN (European Article Number)4030661535142
Mission time20
Length of sensor119.5 mm
Width of sensor40 mm
Height of sensor20 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
Actuating speed, maximum0.5 m/s
NoteObserve the maximum tightening torque of the fixing screws used.
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-40 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Mountingmounting holes countersink
Degree of pollution3
Protection classIII
Other ParametersOperating current: 1,200 | Coding: Individual coding, multiple teaching | Mechanical lifetime, actuator cycles: 500,000 | ACE reference article number: 11931058 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Rated operating voltage: 24 VDC - 15 % / + 10 % (stabilised PELV) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Category: 2 | Test pulse duration, maximum: 5 | Note (Manual release): Manual release from side | Interlocking principle: bistable | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Property class: 8.8 / 80 | Integral system diagnostics, status: Yes | Current consumption at 24V, maximum: 15 | Mechanical lifetime, locking cycles: 1,000,000 | Note (Mechanical lifetime): from device version V2 (V1 = 200.000 actuator cycles) | Series-wiring: Yes | Cross-circuit detection: Yes | Installation conditions (mechanical): arbitrarily | PFH value: 3.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | REVIEW_ELEC_WIRING_GENERAL_GPV: 1000263857 | Current consumption at 24 V: 10 ... 15 mA | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Recommendation (actuator): AZM40-B1 | External wire and device fuse rating: 2 A gG | Design of control elements: OSSD, short-circuit proof, p-type | Classification ZVEI CB24I, Sink: C1 | PFD value: 8.90 x 10⁻⁵ | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Working principle: RFID | Transmitter output RFID, maximum: -6 | CADENAS: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Tightening torque of the fixing screws: 4 ... 6 Nm | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Safety Integrity Level (SIL), suitable for applications in: 2 | Current, Utilisation category DC-13: 0.05 | Switching frequency, maximum: 0.25 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Tightening torque of the fixing screws, maximum: 6 | Current consumption magnet at switching moment, peak: 600 mA / 100 ms | TOL_VOLT_OPERAT_DC_MAX: 10 | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Unlocking: Rotating unlatcher | Duration of risk, maximum: 200 | Performance Level, up to: e | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Current consumption at 24V, minimum: 10 | TOL_VOLT_OPERAT_DC_MIN: -15 | Latching force: 40 N | Manual release: Yes | Actuating angle: 180 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Note (Latch force): +/- 25% | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Designation, Safety outputs: Y1 and Y2 | Tightening torque of the fixing screws, minimum: 4 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Type of the fixing screws: 2x M5