Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM40B-I2-ST-1P2P

Schmersal AZM40B-I2-ST-1P2P

Model: AZM40B-I2-ST-1P2P
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 14 views

Products Introduction

Schmersal AZM40B-I2-ST-1P2P (Order No: 103034195) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: mounting holes countersink; Ambie...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM40B-I2-ST-1P2P, Order No: 103034195. Competitive pricing, fast quotation.

Schmersal AZM40B-I2-ST-1P2P - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM40B-I2-ST-1P2P is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight270 g
Net weight270 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, FCC, IC, UKCA, ANATEL
Housing materialLight alloy die cast and plastic (glass-fibre reinforced thermoplastic)
EAN (European Article Number)4030661535203
Mission time20
Length of sensor119.5 mm
Width of sensor40 mm
Height of sensor20 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
Actuating speed, maximum0.5 m/s
NoteObserve the maximum tightening torque of the fixing screws used.
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-40 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Mountingmounting holes countersink
Degree of pollution3
Protection classIII
Other ParametersOperating current: 1,200 | Coding: Individual coding, multiple teaching | Mechanical lifetime, actuator cycles: 500,000 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Rated operating voltage: 24 VDC - 15 % / + 10 % (stabilised PELV) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | External wire and device fuse rating: 2 A gG | Test pulse duration, maximum: 5 | Note (Manual release): Manual release from side | Interlocking principle: bistable | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Property class: 8.8 / 80 | Integral system diagnostics, status: Yes | REVIEW_ELEC_WIRING_GENERAL_GPV: 1000263869 | Current consumption at 24V, maximum: 15 | Mechanical lifetime, locking cycles: 1,000,000 | Note (Mechanical lifetime): from device version V2 (V1 = 200.000 actuator cycles) | Series-wiring: Yes | Cross-circuit detection: Yes | Installation conditions (mechanical): arbitrarily | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Category: 4 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Current consumption at 24 V: 10 ... 15 mA | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Recommendation (actuator): AZM40-B1 | Design of control elements: OSSD, short-circuit proof, p-type | Actuator monitored: Yes | Classification ZVEI CB24I, Sink: C1 | PFD value: 8.90 x 10⁻⁵ | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Working principle: RFID | Transmitter output RFID, maximum: -6 | CADENAS: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Tightening torque of the fixing screws: 4 ... 6 Nm | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Switching frequency, maximum: 0.25 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Tightening torque of the fixing screws, maximum: 6 | Current consumption magnet at switching moment, peak: 600 mA / 100 ms | TOL_VOLT_OPERAT_DC_MAX: 10 | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Unlocking: Rotating unlatcher | Duration of risk, maximum: 200 | Performance Level, up to: e | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Current consumption at 24V, minimum: 10 | TOL_VOLT_OPERAT_DC_MIN: -15 | Latching force: 40 N | Manual release: Yes | Actuating angle: 180 | PIN 7: Y2 Safety output 2 | Voltage type: DC | ACE reference article number: 11931055 | Length of sensor chain, maximum: 200 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | Note (Latch force): +/- 25% | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Designation, Safety outputs: Y1 and Y2 | Tightening torque of the fixing screws, minimum: 4 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | PFH value: 1.10 x 10⁻⁹ | Type of the fixing screws: 2x M5

More Schmersal Products from Glorient

In addition to AZM40B-I2-ST-1P2P, Glorient also supplies:

AZ 17-02ZI B5 Order No: 101122854
TESF/CC/0 Order No: 101182695
A-K8P-M12-S-G-2,5M-GY-1-X-A-4 Order No: 103011411
MBK311GB/FL Order No: 103009764
EX-T4VH 355-11Z-3G/D Order No: 151193946
TS 336-02Z-M20-1347 Order No: 151158420
TZF.NEM24VDC Order No: 131027523
AZM 415-11/11ZPK 110VAC Order No: 101167202
AZM201BZ-ST-T-AS-A-P Order No: 103025870
BNS 260-11/01Z-L 5,0M Order No: 101190977
STW-SL-N-08-600-2-L2 Order No: 103043648
NHS16/2-POL-3050 Order No: 103039225
TA 471-03/03Y Order No: 101061139
T4V7H 355-20Z-RMS Order No: 151147555
Z4V7H 336-02Z-2138 Order No: 151166561
PS116-Z11-LR500-K210 Order No: 103012518
AZ 3350-12ZUEK Order No: 151214053
CSS 8-180-2P+D-M-LST Order No: 101169560
VORSATZ 5C 235 KPL. ERSATZTEIL Order No: 151104457
SHGV/D01/64+BO Order No: 103013201
PS316-Z12-ST-J300 Order No: 103038021
ZR 335-11Z-ST-RMS Order No: 151159687
AZ 17-11ZK Order No: 101121960
T1K 355-12ZUE Order No: 101148284
WS6K Order No: 101007302
BNS 36-02ZG-L 10,0M Order No: 103012611
SMS 4-500-1500-0208 Order No: 103012515
TS 236-02Z-1297 Order No: 151099768

Related Guides

Gross weight270 g
Net weight270 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, FCC, IC, UKCA, ANATEL
Housing materialLight alloy die cast and plastic (glass-fibre reinforced thermoplastic)
EAN (European Article Number)4030661535203
Mission time20
Length of sensor119.5 mm
Width of sensor40 mm
Height of sensor20 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
Actuating speed, maximum0.5 m/s
NoteObserve the maximum tightening torque of the fixing screws used.
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-40 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Mountingmounting holes countersink
Degree of pollution3
Protection classIII
Other ParametersOperating current: 1,200 | Coding: Individual coding, multiple teaching | Mechanical lifetime, actuator cycles: 500,000 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Rated operating voltage: 24 VDC - 15 % / + 10 % (stabilised PELV) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | External wire and device fuse rating: 2 A gG | Test pulse duration, maximum: 5 | Note (Manual release): Manual release from side | Interlocking principle: bistable | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Property class: 8.8 / 80 | Integral system diagnostics, status: Yes | REVIEW_ELEC_WIRING_GENERAL_GPV: 1000263869 | Current consumption at 24V, maximum: 15 | Mechanical lifetime, locking cycles: 1,000,000 | Note (Mechanical lifetime): from device version V2 (V1 = 200.000 actuator cycles) | Series-wiring: Yes | Cross-circuit detection: Yes | Installation conditions (mechanical): arbitrarily | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Category: 4 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Current consumption at 24 V: 10 ... 15 mA | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Recommendation (actuator): AZM40-B1 | Design of control elements: OSSD, short-circuit proof, p-type | Actuator monitored: Yes | Classification ZVEI CB24I, Sink: C1 | PFD value: 8.90 x 10⁻⁵ | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Working principle: RFID | Transmitter output RFID, maximum: -6 | CADENAS: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Tightening torque of the fixing screws: 4 ... 6 Nm | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Switching frequency, maximum: 0.25 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Tightening torque of the fixing screws, maximum: 6 | Current consumption magnet at switching moment, peak: 600 mA / 100 ms | TOL_VOLT_OPERAT_DC_MAX: 10 | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Unlocking: Rotating unlatcher | Duration of risk, maximum: 200 | Performance Level, up to: e | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Current consumption at 24V, minimum: 10 | TOL_VOLT_OPERAT_DC_MIN: -15 | Latching force: 40 N | Manual release: Yes | Actuating angle: 180 | PIN 7: Y2 Safety output 2 | Voltage type: DC | ACE reference article number: 11931055 | Length of sensor chain, maximum: 200 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | Note (Latch force): +/- 25% | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Designation, Safety outputs: Y1 and Y2 | Tightening torque of the fixing screws, minimum: 4 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | PFH value: 1.10 x 10⁻⁹ | Type of the fixing screws: 2x M5