Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM201Z-I2-ST2-T-SD2P-A

Schmersal AZM201Z-I2-ST2-T-SD2P-A

Model: AZM201Z-I2-ST2-T-SD2P-A
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 15 views

Products Introduction

Schmersal AZM201Z-I2-ST2-T-SD2P-A (Order No: 103035058) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +60 °C; ...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM201Z-I2-ST2-T-SD2P-A, Order No: 103035058. Competitive pricing, fast quotation.

Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.

More Schmersal Products from Glorient

In addition to AZM201Z-I2-ST2-T-SD2P-A, Glorient also supplies:

SEPLC05.2.3.1.22/95 Order No: 101188797
SHGV/B01/300+BOW Order No: 103039326
PS215-T12-H200 Order No: 103014996
NDLP30BL/WS Order No: 103009741
EDRR40.1RT Order No: 101184008
SHGV/LD1/216/34+BO Order No: 101198542
AZM150SK-02/11RIA-024-B6L Order No: 153032216
SVE1/52-24VDC Order No: 101197172
SEPLC05.2.L.22.Z7 Order No: 101211323
SVM1/53-10/103/A Order No: 101213522
UEBERG.ST. M20X1,5-NPT1/2" M20NPT1/2PASW Order No: 101212434
TR 236-11Z-M16 Order No: 151160156
TQ 700-02 Order No: 101192480
GUMMISCHLAUCHRING 4X8X8 Order No: 101070438
STW-C-10X25-3100-2 Order No: 103047427
SHGV/B01/216+BOR Order No: 101215732
SVE2/162/162-24VDC Order No: 101203752
SHGV/B01/140+BOW Order No: 101198406
EDTRT/504 Order No: 101187540
SHGV/B01/215+BO Order No: 101198152
V-SK8P-M12/M8-S-G-0,5M-BK-2-X-A-4 Order No: 103009917
UK 433Y-RMS Order No: 101180825
GLUEHLAMPE L48/7 BA7S 48V/1,2W Order No: 101001831
SHGV/LD1/117/67+BO Order No: 101215697
SHG01.103/90 Order No: 101009662
SHGV/D01/199+BO Order No: 103015443
SYMBOLTRAEGER KB-9.1 WEISS Order No: 101015649
Z4K 236-11Z-M20 Order No: 151163117
AZ 3350-12ZUEK Order No: 151214053
TQ215AR-11 Order No: 103044929

Related Guides

Gross weight595 g
Net weight595 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078519 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesUKCA
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661537085
Mission time20
TerminationConnector M12, 8-pole
Mechanical lifetime, minimum1,000,000
Length of sensor50 mm
Width of sensor40 mm
Height of sensor220 mm
Utilisation category DC-1324 VDC / 0.05 A
Required rated short-circuit current100 A
Actuating speed, maximum0.2 m/s
NoteTorx T10
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersOperating current: 1,200 | Coding: Individual coding, multiple teaching | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Wiring capacitance: 50 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Tightening torque of the fastening screws for the housing cover: 0.7 ... 1 Nm (Torx T10) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Test pulse duration, maximum: 5 | Allowed type of cable: solid single-wire, solid multi-wire, flexible | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): AZ/AZM201-B1 | Current consumption with magnet ON, average : 200 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | PFH value: 1.00 x 10⁻⁸ | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | PFD value: 8.90 x 10⁻⁴ | Serial diagnostics: Yes | External wire and device fuse rating: 2 A gG | Performance Level, up to: d | Classification ZVEI CB24I, Sink: C1 | Fuse rating to UL 508, maximum: 4 | Test pulse interval, minimum: 40 | Number of series-wiring of sensors: 31 | Magnet switch-on time: 100 | Tightening torque of the fixing screws, maximum: 8 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | CADENAS: Yes | Latching force: 30 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT serial diagnostic output | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Rated operating current (safety outputs): 250 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Connection type: Screw terminals, Connector M12, 8-pole, Spring pulley connection | TOL_VOLT_OPERAT_DC_MAX: 10 | Current consumption with magnet ON, peak: 700 mA / 100 ms | Reaction time, switching off safety outputs via actuator, maximum: 100 | Wire cross-section: 23 ... 15 AWG | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Designation, Serial diagnostic SD: OUT | Manual release: Yes | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Safety Integrity Level (SIL), suitable for applications in: 2 | Length of sensor chain, maximum: 200 | Current, Utilisation category DC-13: 0.25 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | PIN 8: IN serial diagnostic input | Degree of protection: IP66, IP67 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Tightening torque of the fastening screws for the housing cover, minimum: 0.7 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Operation current: 150