Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM40B-I2-ST-1P2P-PH

Schmersal AZM40B-I2-ST-1P2P-PH

Model: AZM40B-I2-ST-1P2P-PH
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 19 views

Products Introduction

Schmersal AZM40B-I2-ST-1P2P-PH (Order No: 103037332) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: mounting holes plain; Ambient ...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM40B-I2-ST-1P2P-PH, Order No: 103037332. Competitive pricing, fast quotation.

Schmersal AZM40B-I2-ST-1P2P-PH - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM40B-I2-ST-1P2P-PH is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight306 g
Net weight306 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, FCC, IC, UKCA, ANATEL
Housing materialLight alloy die cast and plastic (glass-fibre reinforced thermoplastic)
EAN (European Article Number)4030661543710
Mission time20
Length of sensor119.5 mm
Width of sensor40 mm
Height of sensor20 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
Actuating speed, maximum0.5 m/s
NoteObserve the maximum tightening torque of the fixing screws used.
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-40 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Mountingmounting holes plain
Degree of pollution3
Protection classIII
Other ParametersOperating current: 1,200 | Coding: Individual coding, multiple teaching | Mechanical lifetime, actuator cycles: 500,000 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Rated operating voltage: 24 VDC - 15 % / + 10 % (stabilised PELV) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Test pulse duration, maximum: 5 | Note (Manual release): Manual release from side | Interlocking principle: bistable | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Property class: 8.8 / 80 | Integral system diagnostics, status: Yes | Recommendation (actuator): AZM40-B1-PH | Current consumption at 24V, maximum: 15 | Mechanical lifetime, locking cycles: 1,000,000 | Note (Mechanical lifetime): from device version V2 (V1 = 200.000 actuator cycles) | Series-wiring: Yes | Cross-circuit detection: Yes | Installation conditions (mechanical): arbitrarily | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Category: 4 | External wire and device fuse rating: 2 A gG | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Current consumption at 24 V: 10 ... 15 mA | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Design of control elements: OSSD, short-circuit proof, p-type | Actuator monitored: Yes | Classification ZVEI CB24I, Sink: C1 | PFD value: 8.90 x 10⁻⁵ | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Working principle: RFID | Transmitter output RFID, maximum: -6 | REVIEW_ELEC_WIRING_GENERAL_GPV: 1000390325 | CADENAS: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Tightening torque of the fixing screws: 4 ... 6 Nm | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Switching frequency, maximum: 0.25 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Tightening torque of the fixing screws, maximum: 6 | Current consumption magnet at switching moment, peak: 600 mA / 100 ms | TOL_VOLT_OPERAT_DC_MAX: 10 | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Unlocking: Rotating unlatcher | Duration of risk, maximum: 200 | Performance Level, up to: e | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Current consumption at 24V, minimum: 10 | TOL_VOLT_OPERAT_DC_MIN: -15 | Latching force: 40 N | ACE reference article number: 11931062 | Manual release: Yes | Actuating angle: 180 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | Note (Latch force): +/- 25% | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Designation, Safety outputs: Y1 and Y2 | Tightening torque of the fixing screws, minimum: 4 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | PFH value: 1.10 x 10⁻⁹ | Type of the fixing screws: 2x M5

More Schmersal Products from Glorient

In addition to AZM40B-I2-ST-1P2P-PH, Glorient also supplies:

PS226-T12-K200 Order No: 103015080
PS316-Z11-K360 Order No: 103015135
SMS 4-1000-1300 Order No: 103007684
SHGV/L01/215+BOW Order No: 101198296
BDF200-NHK-20-LTWH-LTWH-LMGN Order No: 103010168
AV21LX40U-GB215 Order No: 103028217
NDLGN/802D Order No: 101189651
E-KB9WS/L00841023 Order No: 101218372
EX-ZR 335-02Z-3G/D Order No: 151192421
SEPLC05.2.S-0503 Order No: 101210588
NDTRT Order No: 101163555
SHGV/EKM153 Order No: 103035590
AZM 170ST-11/02ZRKA 24VAC/DC Order No: 101186189
AZM201Z-I2-ST2-T-1P2PW Order No: 103013486
ENAF9.401SEY Order No: 101177885
TQ 421-10Y-M20-997 Order No: 101156861
EX-SHGV/L01/217+BOWR-2GD Order No: 103037048
SVE1/SR/108GN/GN-24VDC Order No: 103035199
PS316-Z11-ST-S300 Order No: 103037627
AZM 415-STS30-06 Order No: 101176867
AV20LHX20U-GB215 Order No: 101142144
AZ 15 ZVRK-M20-1762 Order No: 101157470
DPN55BL Order No: 101006972
SHGV/LD1/243/43+BOW Order No: 103010269
BNS 120-12Z 10,0M Order No: 101160113
WSN21/0-I Order No: 101007206
SHGV/LD1/100/71+BOF/HIS.1 Order No: 103050976

Related Guides

Gross weight306 g
Net weight306 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, FCC, IC, UKCA, ANATEL
Housing materialLight alloy die cast and plastic (glass-fibre reinforced thermoplastic)
EAN (European Article Number)4030661543710
Mission time20
Length of sensor119.5 mm
Width of sensor40 mm
Height of sensor20 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
Actuating speed, maximum0.5 m/s
NoteObserve the maximum tightening torque of the fixing screws used.
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-40 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Mountingmounting holes plain
Degree of pollution3
Protection classIII
Other ParametersOperating current: 1,200 | Coding: Individual coding, multiple teaching | Mechanical lifetime, actuator cycles: 500,000 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Rated operating voltage: 24 VDC - 15 % / + 10 % (stabilised PELV) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Test pulse duration, maximum: 5 | Note (Manual release): Manual release from side | Interlocking principle: bistable | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Property class: 8.8 / 80 | Integral system diagnostics, status: Yes | Recommendation (actuator): AZM40-B1-PH | Current consumption at 24V, maximum: 15 | Mechanical lifetime, locking cycles: 1,000,000 | Note (Mechanical lifetime): from device version V2 (V1 = 200.000 actuator cycles) | Series-wiring: Yes | Cross-circuit detection: Yes | Installation conditions (mechanical): arbitrarily | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Category: 4 | External wire and device fuse rating: 2 A gG | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Current consumption at 24 V: 10 ... 15 mA | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Design of control elements: OSSD, short-circuit proof, p-type | Actuator monitored: Yes | Classification ZVEI CB24I, Sink: C1 | PFD value: 8.90 x 10⁻⁵ | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Working principle: RFID | Transmitter output RFID, maximum: -6 | REVIEW_ELEC_WIRING_GENERAL_GPV: 1000390325 | CADENAS: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Tightening torque of the fixing screws: 4 ... 6 Nm | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Switching frequency, maximum: 0.25 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Tightening torque of the fixing screws, maximum: 6 | Current consumption magnet at switching moment, peak: 600 mA / 100 ms | TOL_VOLT_OPERAT_DC_MAX: 10 | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Unlocking: Rotating unlatcher | Duration of risk, maximum: 200 | Performance Level, up to: e | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Current consumption at 24V, minimum: 10 | TOL_VOLT_OPERAT_DC_MIN: -15 | Latching force: 40 N | ACE reference article number: 11931062 | Manual release: Yes | Actuating angle: 180 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | Note (Latch force): +/- 25% | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Designation, Safety outputs: Y1 and Y2 | Tightening torque of the fixing screws, minimum: 4 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | PFH value: 1.10 x 10⁻⁹ | Type of the fixing screws: 2x M5