Schmersal RSS260-I2-D-F1-Q-LSTM8-8-0,1M (Order No: 103040369) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: A 20 mm screw length u...
Glorient offers competitive supply of Schmersal RSS260-I2-D-F1-Q-LSTM8-8-0,1M, Order No: 103040369. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to RSS260-I2-D-F1-Q-LSTM8-8-0,1M, Glorient also supplies:
| Gross weight | 68 g |
| Net weight | 68 g |
| Ambient temperature | -28 ... +65 °C |
| Ambient temperature, maximum | +65 °C |
| Ambient temperature, minimum | -28 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP67 |
| Certificates | TÜV, cULus, FCC, IC, ANATEL |
| Housing material | Plastic, thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661553740 |
| Mission time | 20 |
| Termination | Connector M8, 8-pole |
| Length of sensor | 29.5 mm |
| Width of sensor | 39.2 mm |
| Height of sensor | 18 mm |
| Utilisation category DC-13 | 24 VDC / 0.25 A |
| Required rated short-circuit current | 100 A |
| Traceparts | Yes |
| Housing construction form | Block |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -28 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -28 °C |
| Mounting | A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws. |
| Degree of pollution | 3 |
| Other Parameters | Coding: Individual coding, multiple teaching | Number of fail-safe digital outputs: 2 | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Number of poles: 8 | Tightening torque of the fixing screws, maximum: 0.8 | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Operating current, minimum: 0.5 | Hysteresis (Switching distance), maximum: 2 | Connection type: cable; Connector M12, 5-pole, A-coded; Connector M12, 8-pole, A-coded; Connector M8, 8-pole | Note (LED switching conditions display): LED green: Supply voltage | Series-wiring: Yes | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Voltage, Utilisation category DC-12: 24 | Active area: front | Operating current: 600 | Restistance to shock: 30 g / 11 ms | Utilisation category DC-12: 24 VDC / 0.25 A | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Classification ZVEI CB24I, Source: C1 | Typical switching distance, lateral: 9 | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Classification ZVEI CB24I, Sink: C1 | Diagnostic output: Yes | Working principle: RFID | Transmitter output RFID, maximum: -6 | Typical switching distance, frontal: 12 | PFH value: 6.80 x 10⁻¹⁰ | PIN 8: without function | Type of the fixing screws: 2x M4 | Rated operating voltage, minimum: 20.4 VDC | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Rated operating voltage, maximum: 26.4 VDC | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Recommendation (actuator): RST-U-2 | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | Reaction time, maximum: 100 | Wiring capacitance: 50 | Rated operating current (safety outputs): 250 | Category: 4 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Rated operating voltage: 24 VDC -15% / +10% | Number of LEDs: 3 | TOL_VOLT_OPERAT_DC_MAX: 10 | Actuating panels: lateral | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Duration of risk, maximum: 200 | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Cascadable: Yes | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Test pulse duration, maximum: 1 | Current consumption of the safety inputs: 5 | Number of semi-conductor outputs with signaling function: 1 | Time to readiness, maximum: 2,000 | Degree of protection: IP65, IP67 | PIN 7: Y2 Safety output 2 | Voltage type: DC | PIN 1: A1 Supply voltage UB | Interfering radiation: IEC 61000-6-4 | Permissible installation altitude above sea level, maximum: 2,000 | Absicherung des Sicherheitsausganges: short-circuit proof, p-type | PFD value: 1.20 x 10⁻⁴ | Overvoltage category: 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Electrical fuse rating, maximum: 2 | Test pulse interval, minimum: 100 | Designation, Safety outputs: Y1 and Y2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |