Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

BDF200-FB-NHK-LT-LT-B-2875

Schmersal BDF200-FB-NHK-LT-LT-B-2875

Model: BDF200-FB-NHK-LT-LT-B-2875
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 14 views

Products Introduction

Schmersal BDF200-FB-NHK-LT-LT-B-2875 (Order No: 103045032) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: interior mounting holes; ...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal BDF200-FB-NHK-LT-LT-B-2875, Order No: 103045032. Competitive pricing, fast quotation.

Schmersal BDF200-FB-NHK-LT-LT-B-2875 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal BDF200-FB-NHK-LT-LT-B-2875 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight280 g
Net weight280 g
Ambient temperature-25 ... +65 °C
Ambient temperature, maximum+65 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 61508
IP Degree of protectionIP65
CertificatesTÜV, cULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661564241
Mission time20
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Mountinginterior mounting holes
Degree of pollution3
Protection classIII
Other ParametersPFH value: 2.89 x 10⁻¹⁰ | Reaction time, maximum: 50 | Number of fail-safe digital outputs: 2 | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Positions used, position 1: Emergency stop, with protective collar | PIN 3: A2 GND | Width: 40 | Design of control elements: short-circuit proof, p-type | EPLAN: Yes | Height: 69 | Switching thresholds: −3 V … 5 V (Low) | Duration of risk, maximum: 100 | Mechanical lifetime, Command devices: 1,000,000 | Switching frequency, maximum: 1 | Operating current: 600 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Classification ZVEI CB24I, Source: C1 | PIN 2: X1 Safety input 1 | Serial diagnostics: No | Wiring capacitance: 50 | Classification ZVEI CB24I, Sink: C1 | Positions used, position 4: Blanking plug | Rated operating voltage: 24 VDC −15 % / +10 % | Operation current: 10 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Positions used, position 2: Illuminated pushbutton, color exchangeable | PIN 5: OUT serial diagnostic output | Voltage, Utilisation category DC-12: 24 | Voltage, Utilisation category DC-13: 24 | Category: 4 | PIN 8: n.c. | TOL_VOLT_OPERAT_DC_MAX: 10 | Mechanical lifetime, Emergency-Stop button: 100,000 | Note (PFH-value): up to max. 5,000 switching cycles/year | PIN 4: Y1 Safety output 1 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Positions used, position 3: Illuminated pushbutton; color exchangeable | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Test pulse duration, maximum: 1 | Designation, Serial diagnostic SD: OUT | Time to readiness, maximum: 2,000 | Field box interface: Yes | PIN 7: Y2 Safety output 2 | Voltage type: DC | Current, Utilisation category DC-13: 0.25 | PIN 1: A1 Supply voltage UB | Note (Ordering data): Notice: see ordering code | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Current, Utilisation category DC-12: 0.25 | Permissible installation altitude above sea level, maximum: 2,000 | Climatic stress: DIN EN 60068 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Test pulse interval, minimum: 100 | Designation, Safety outputs: Y1 and Y2 | Depth: 233.5 | Performance Level, up to: e | Type of the fixing screws: 2x M5

More Schmersal Products from Glorient

In addition to BDF200-FB-NHK-LT-LT-B-2875, Glorient also supplies:

ACC-PWR-RC-4MM-ZN Order No: 101077072
SLC440-ER-0250-30 Order No: 101216714
SET AZ 15ZVRK-ST-B1-2864-1 Order No: 103008684
SHGV/B01/216+BOW Order No: 101198412
SHGV/EKM196 Order No: 103040681
T1R 236-11Z-U90-2088-1 Order No: 151115899
SPRG-ZG-D6,0X1,5-L80,0 Order No: 101070203
SHGV/ESS21S2/74/103 Order No: 101205796
T4S 256-02Z Order No: 101112762
HEBEL 2H KPL. 302 EP. 1,0 Order No: 101064218
SMS 4-1080-1100-0315 Order No: 103038936
EX-SVE1/102-24VDC Order No: 103015363
RDLMGB Order No: 101188169
EDR70SW Order No: 101006336
Z4VH 332-11Y-ST Order No: 101147981
SHGV/L01/113+BO Order No: 101197794
T. 471-03/03Y-H-840 Order No: 101210333
SHGV/D01/68+BO Order No: 103043308
SLC440COM-ER-0730-14-1700 Order No: 103040454
TD 250-02/02Z Order No: 101058179
TA 471-03/03Y-H-RMS GB 130 Order No: 101110011
AZM190-11/01RKN-24VDC Order No: 131030169
Z4VH 336-11Z-M20-1335 Order No: 101166969
AZM 415-STS30-01-9220 Order No: 101177043
SHGV/L01/160+BO Order No: 101197841
TQ215AR-11 Order No: 103044929
PS316-T11UE-S300 Order No: 103015150
SZ 415-2-2477 Order No: 101178237
SVE1/57-3Ö-24VDC Order No: 101197596

Related Guides

Gross weight280 g
Net weight280 g
Ambient temperature-25 ... +65 °C
Ambient temperature, maximum+65 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 61508
IP Degree of protectionIP65
CertificatesTÜV, cULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661564241
Mission time20
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Mountinginterior mounting holes
Degree of pollution3
Protection classIII
Other ParametersPFH value: 2.89 x 10⁻¹⁰ | Reaction time, maximum: 50 | Number of fail-safe digital outputs: 2 | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Positions used, position 1: Emergency stop, with protective collar | PIN 3: A2 GND | Width: 40 | Design of control elements: short-circuit proof, p-type | EPLAN: Yes | Height: 69 | Switching thresholds: −3 V … 5 V (Low) | Duration of risk, maximum: 100 | Mechanical lifetime, Command devices: 1,000,000 | Switching frequency, maximum: 1 | Operating current: 600 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Classification ZVEI CB24I, Source: C1 | PIN 2: X1 Safety input 1 | Serial diagnostics: No | Wiring capacitance: 50 | Classification ZVEI CB24I, Sink: C1 | Positions used, position 4: Blanking plug | Rated operating voltage: 24 VDC −15 % / +10 % | Operation current: 10 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Positions used, position 2: Illuminated pushbutton, color exchangeable | PIN 5: OUT serial diagnostic output | Voltage, Utilisation category DC-12: 24 | Voltage, Utilisation category DC-13: 24 | Category: 4 | PIN 8: n.c. | TOL_VOLT_OPERAT_DC_MAX: 10 | Mechanical lifetime, Emergency-Stop button: 100,000 | Note (PFH-value): up to max. 5,000 switching cycles/year | PIN 4: Y1 Safety output 1 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Positions used, position 3: Illuminated pushbutton; color exchangeable | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Test pulse duration, maximum: 1 | Designation, Serial diagnostic SD: OUT | Time to readiness, maximum: 2,000 | Field box interface: Yes | PIN 7: Y2 Safety output 2 | Voltage type: DC | Current, Utilisation category DC-13: 0.25 | PIN 1: A1 Supply voltage UB | Note (Ordering data): Notice: see ordering code | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Current, Utilisation category DC-12: 0.25 | Permissible installation altitude above sea level, maximum: 2,000 | Climatic stress: DIN EN 60068 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Test pulse interval, minimum: 100 | Designation, Safety outputs: Y1 and Y2 | Depth: 233.5 | Performance Level, up to: e | Type of the fixing screws: 2x M5