Schmersal RSS260-I2-D-F1-ST (Order No: 103051710) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: A 20 mm screw length usually suf.....
Glorient offers competitive supply of Schmersal RSS260-I2-D-F1-ST, Order No: 103051710. Competitive pricing, fast quotation.
Schmersal RSS260-I2-D-F1-ST - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal RSS260-I2-D-F1-ST is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 50 g |
| Net weight | 50 g |
| Ambient temperature | -28 ... +65 °C |
| Ambient temperature, maximum | +65 °C |
| Ambient temperature, minimum | -28 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP67 |
| Certificates | TÜV, cULus, FCC, IC, ANATEL |
| Housing material | Plastic, thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661630540 |
| Mission time | 20 |
| Termination | Connector M8, 8-pole |
| Length of sensor | 29.5 mm |
| Width of sensor | 39.2 mm |
| Height of sensor | 18 mm |
| Utilisation category DC-13 | 24 VDC / 0.25 A |
| Required rated short-circuit current | 100 A |
| Housing construction form | Block |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -28 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -28 °C |
| Mounting | A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws. |
| Degree of pollution | 3 |
| Other Parameters | Coding: Individual coding, multiple teaching | Number of fail-safe digital outputs: 2 | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | Number of poles: 8 | Tightening torque of the fixing screws, maximum: 0.8 | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Operating current, minimum: 0.5 | Hysteresis (Switching distance), maximum: 2 | Connection type: cable; Connector M12, 5-pole, A-coded; Connector M12, 8-pole, A-coded; Connector M8, 8-pole | Note (LED switching conditions display): LED green: Supply voltage | Series-wiring: Yes | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Voltage, Utilisation category DC-12: 24 | Active area: front | Operating current: 600 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Classification ZVEI CB24I, Source: C1 | Typical switching distance, lateral: 9 | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Classification ZVEI CB24I, Sink: C1 | Diagnostic output: Yes | Working principle: RFID | Transmitter output RFID, maximum: -6 | Typical switching distance, frontal: 12 | PFH value: 6.80 x 10⁻¹⁰ | PIN 8: without function | Type of the fixing screws: 2x M4 | Rated operating voltage, minimum: 20.4 VDC | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Rated operating voltage, maximum: 26.4 VDC | Utilisation category DC-12: 24 VDC / 0.25 A | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Recommendation (actuator): RST-U-2 | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | Reaction time, maximum: 100 | Wiring capacitance: 50 | Rated operating current (safety outputs): 250 | Category: 4 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Rated operating voltage: 24 VDC -15% / +10% | Number of LEDs: 3 | TOL_VOLT_OPERAT_DC_MAX: 10 | Actuating panels: lateral | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Duration of risk, maximum: 200 | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Cascadable: Yes | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Test pulse duration, maximum: 1 | Current consumption of the safety inputs: 5 | Number of semi-conductor outputs with signaling function: 1 | Time to readiness, maximum: 2,000 | Degree of protection: IP65, IP67 | PIN 7: Y2 Safety output 2 | Voltage type: DC | PIN 1: A1 Supply voltage UB | Interfering radiation: IEC 61000-6-4 | Permissible installation altitude above sea level, maximum: 2,000 | Absicherung des Sicherheitsausganges: short-circuit proof, p-type | PFD value: 1.20 x 10⁻⁴ | Overvoltage category: 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Electrical fuse rating, maximum: 2 | Test pulse interval, minimum: 100 | Designation, Safety outputs: Y1 and Y2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |
In addition to RSS260-I2-D-F1-ST, Glorient also supplies:
| Gross weight | 50 g |
| Net weight | 50 g |
| Ambient temperature | -28 ... +65 °C |
| Ambient temperature, maximum | +65 °C |
| Ambient temperature, minimum | -28 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP67 |
| Certificates | TÜV, cULus, FCC, IC, ANATEL |
| Housing material | Plastic, thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661630540 |
| Mission time | 20 |
| Termination | Connector M8, 8-pole |
| Length of sensor | 29.5 mm |
| Width of sensor | 39.2 mm |
| Height of sensor | 18 mm |
| Utilisation category DC-13 | 24 VDC / 0.25 A |
| Required rated short-circuit current | 100 A |
| Housing construction form | Block |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -28 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -28 °C |
| Mounting | A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws. |
| Degree of pollution | 3 |
| Other Parameters | Coding: Individual coding, multiple teaching | Number of fail-safe digital outputs: 2 | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | Number of poles: 8 | Tightening torque of the fixing screws, maximum: 0.8 | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Operating current, minimum: 0.5 | Hysteresis (Switching distance), maximum: 2 | Connection type: cable; Connector M12, 5-pole, A-coded; Connector M12, 8-pole, A-coded; Connector M8, 8-pole | Note (LED switching conditions display): LED green: Supply voltage | Series-wiring: Yes | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Voltage, Utilisation category DC-12: 24 | Active area: front | Operating current: 600 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Classification ZVEI CB24I, Source: C1 | Typical switching distance, lateral: 9 | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Classification ZVEI CB24I, Sink: C1 | Diagnostic output: Yes | Working principle: RFID | Transmitter output RFID, maximum: -6 | Typical switching distance, frontal: 12 | PFH value: 6.80 x 10⁻¹⁰ | PIN 8: without function | Type of the fixing screws: 2x M4 | Rated operating voltage, minimum: 20.4 VDC | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Rated operating voltage, maximum: 26.4 VDC | Utilisation category DC-12: 24 VDC / 0.25 A | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Recommendation (actuator): RST-U-2 | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | Reaction time, maximum: 100 | Wiring capacitance: 50 | Rated operating current (safety outputs): 250 | Category: 4 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Rated operating voltage: 24 VDC -15% / +10% | Number of LEDs: 3 | TOL_VOLT_OPERAT_DC_MAX: 10 | Actuating panels: lateral | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Duration of risk, maximum: 200 | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Cascadable: Yes | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Test pulse duration, maximum: 1 | Current consumption of the safety inputs: 5 | Number of semi-conductor outputs with signaling function: 1 | Time to readiness, maximum: 2,000 | Degree of protection: IP65, IP67 | PIN 7: Y2 Safety output 2 | Voltage type: DC | PIN 1: A1 Supply voltage UB | Interfering radiation: IEC 61000-6-4 | Permissible installation altitude above sea level, maximum: 2,000 | Absicherung des Sicherheitsausganges: short-circuit proof, p-type | PFD value: 1.20 x 10⁻⁴ | Overvoltage category: 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Electrical fuse rating, maximum: 2 | Test pulse interval, minimum: 100 | Designation, Safety outputs: Y1 and Y2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |