Schmersal AES 1112 24 VDC (Order No: 101128982) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Snaps onto standard DIN rail to ...;...
Glorient offers competitive supply of Schmersal AES 1112 24 VDC, Order No: 101128982. Competitive pricing, fast quotation.
Schmersal AES 1112 24 VDC - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal AES 1112 24 VDC is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 122 g |
| Net weight | 122 g |
| Ambient temperature | +0 ... +55 °C |
| Ambient temperature, maximum | +55 °C |
| Ambient temperature, minimum | +0 °C |
| Standards | EN IEC 60947-5-3 |
| Certificates | cULus |
| Housing material | Glass-fibre reinforced thermoplastic, ventilated |
| EAN (European Article Number) | 4030661059259 |
| Mission time | 20 |
| Mechanical lifetime, minimum | 10,000,000 |
| Thermal test current | 4 A |
| Cable section, maximum | 2.5 mm² |
| Material of the contacts, electrical | AgCdO |
| Number of safety contacts | 1 |
| Resistance to vibrations | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
| Storage and transport temperature | -25 ... +70 °C |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
| Degree of pollution | 2 |
| Other Parameters | Current, Utilisation category DC-12: 0.1 | Switching capacity, maximum: 250 | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Climatic stress: BG-GS-ET-14 | Drop-out delay in case of emergency, typically: 20 | Current, Utilisation category DC-13: 2 | Integral system diagnostics, status: Yes | Reset after disconnection of supply voltage : Yes | Terminal designations: IEC/EN 60947-1 | Rated control voltage at DC, maximum: 27.6 | Cable section: 2.5 mm² | Height: 75 | Restistance to shock: 30 g / 11 ms | Voltage, Utilisation category DC-12: 24 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Pull-in delay at automatic start, maximum, typically: 100 | Conduction resistance, maximum: 40 | Number of normally open (NO): 1 | Automatic reset function: Yes | Number of LEDs: 1 | Switching capacity, minimum: 10 | Operating voltage: 24 VDC -15 % / +15 % | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 2 A | Notice: for max. 50,000 switching cycles/year and max. 80% contact load | Terminal (mechanical): Screw terminals | IP Degree of protection of the installation space: IP54 | Drop-out delay in case of power failure, typically: 80 | Allowed type of cable: solid single-wire | Rated operating voltage: 24 VDC ± 15 % | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 3 A | Number of normally closed (NC): 2 | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | Pull-in delay at RESET, typically: 20 | Safety Integrity Level (SIL), suitable for applications in: 1 | IP Degree of protection of the enclosure: IP40 | PFH value: 1.14 x 10⁻⁶ | TOL_VOLT_OPERAT_DC_MIN: -15 | Width: 22.5 | Note (Contact resistance): in new state | Category: 1 | Performance Level, up to: c | Voltage type: DC | Current, Utilisation category AC-15: 3 | Note (Wiring diagram): Monitoring one guard door: If only one magnetic safety sensor is connected to S1, the terminals S22, S32 and C of S2 must be bridged. | TOL_VOLT_OPERAT_DC_MAX: 15 | Note (applications): Safety sensor | Depth: 110 | Tightening torque of Clips: 0.6 | Electrical power consumption: 2.4 | Stop-Category: 0 | Voltage, Utilisation category AC-15: 230 | ACE reference article number: 193481 | Indicated operating states: Authorised operation | Utilisation category DC-12: 24_0.1 |
In addition to AES 1112 24 VDC, Glorient also supplies:
| Gross weight | 122 g |
| Net weight | 122 g |
| Ambient temperature | +0 ... +55 °C |
| Ambient temperature, maximum | +55 °C |
| Ambient temperature, minimum | +0 °C |
| Standards | EN IEC 60947-5-3 |
| Certificates | cULus |
| Housing material | Glass-fibre reinforced thermoplastic, ventilated |
| EAN (European Article Number) | 4030661059259 |
| Mission time | 20 |
| Mechanical lifetime, minimum | 10,000,000 |
| Thermal test current | 4 A |
| Cable section, maximum | 2.5 mm² |
| Material of the contacts, electrical | AgCdO |
| Number of safety contacts | 1 |
| Resistance to vibrations | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
| Storage and transport temperature | -25 ... +70 °C |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
| Degree of pollution | 2 |
| Other Parameters | Current, Utilisation category DC-12: 0.1 | Switching capacity, maximum: 250 | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Climatic stress: BG-GS-ET-14 | Drop-out delay in case of emergency, typically: 20 | Current, Utilisation category DC-13: 2 | Integral system diagnostics, status: Yes | Reset after disconnection of supply voltage : Yes | Terminal designations: IEC/EN 60947-1 | Rated control voltage at DC, maximum: 27.6 | Cable section: 2.5 mm² | Height: 75 | Restistance to shock: 30 g / 11 ms | Voltage, Utilisation category DC-12: 24 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Pull-in delay at automatic start, maximum, typically: 100 | Conduction resistance, maximum: 40 | Number of normally open (NO): 1 | Automatic reset function: Yes | Number of LEDs: 1 | Switching capacity, minimum: 10 | Operating voltage: 24 VDC -15 % / +15 % | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 2 A | Notice: for max. 50,000 switching cycles/year and max. 80% contact load | Terminal (mechanical): Screw terminals | IP Degree of protection of the installation space: IP54 | Drop-out delay in case of power failure, typically: 80 | Allowed type of cable: solid single-wire | Rated operating voltage: 24 VDC ± 15 % | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 3 A | Number of normally closed (NC): 2 | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | Pull-in delay at RESET, typically: 20 | Safety Integrity Level (SIL), suitable for applications in: 1 | IP Degree of protection of the enclosure: IP40 | PFH value: 1.14 x 10⁻⁶ | TOL_VOLT_OPERAT_DC_MIN: -15 | Width: 22.5 | Note (Contact resistance): in new state | Category: 1 | Performance Level, up to: c | Voltage type: DC | Current, Utilisation category AC-15: 3 | Note (Wiring diagram): Monitoring one guard door: If only one magnetic safety sensor is connected to S1, the terminals S22, S32 and C of S2 must be bridged. | TOL_VOLT_OPERAT_DC_MAX: 15 | Note (applications): Safety sensor | Depth: 110 | Tightening torque of Clips: 0.6 | Electrical power consumption: 2.4 | Stop-Category: 0 | Voltage, Utilisation category AC-15: 230 | ACE reference article number: 193481 | Indicated operating states: Authorised operation | Utilisation category DC-12: 24_0.1 |