Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AES 1112 24 VDC

Schmersal AES 1112 24 VDC

Model: AES 1112 24 VDC
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 19 views

Products Introduction

Schmersal AES 1112 24 VDC (Order No: 101128982) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Snaps onto standard DIN rail to ...;...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AES 1112 24 VDC, Order No: 101128982. Competitive pricing, fast quotation.

Schmersal AES 1112 24 VDC - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AES 1112 24 VDC is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight122 g
Net weight122 g
Ambient temperature+0 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum+0 °C
StandardsEN IEC 60947-5-3
CertificatescULus
Housing materialGlass-fibre reinforced thermoplastic, ventilated
EAN (European Article Number)4030661059259
Mission time20
Mechanical lifetime, minimum10,000,000
Thermal test current4 A
Cable section, maximum2.5 mm²
Material of the contacts, electricalAgCdO
Number of safety contacts1
Resistance to vibrations10...55 Hz, Amplitude 0.35 mm, ± 15 %
Storage and transport temperature-25 ... +70 °C
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
MountingSnaps onto standard DIN rail to EN 60715
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Degree of pollution2
Other ParametersCurrent, Utilisation category DC-12: 0.1 | Switching capacity, maximum: 250 | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Climatic stress: BG-GS-ET-14 | Drop-out delay in case of emergency, typically: 20 | Current, Utilisation category DC-13: 2 | Integral system diagnostics, status: Yes | Reset after disconnection of supply voltage : Yes | Terminal designations: IEC/EN 60947-1 | Rated control voltage at DC, maximum: 27.6 | Cable section: 2.5 mm² | Height: 75 | Restistance to shock: 30 g / 11 ms | Voltage, Utilisation category DC-12: 24 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Pull-in delay at automatic start, maximum, typically: 100 | Conduction resistance, maximum: 40 | Number of normally open (NO): 1 | Automatic reset function: Yes | Number of LEDs: 1 | Switching capacity, minimum: 10 | Operating voltage: 24 VDC -15 % / +15 % | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 2 A | Notice: for max. 50,000 switching cycles/year and max. 80% contact load | Terminal (mechanical): Screw terminals | IP Degree of protection of the installation space: IP54 | Drop-out delay in case of power failure, typically: 80 | Allowed type of cable: solid single-wire | Rated operating voltage: 24 VDC ± 15 % | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 3 A | Number of normally closed (NC): 2 | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | Pull-in delay at RESET, typically: 20 | Safety Integrity Level (SIL), suitable for applications in: 1 | IP Degree of protection of the enclosure: IP40 | PFH value: 1.14 x 10⁻⁶ | TOL_VOLT_OPERAT_DC_MIN: -15 | Width: 22.5 | Note (Contact resistance): in new state | Category: 1 | Performance Level, up to: c | Voltage type: DC | Current, Utilisation category AC-15: 3 | Note (Wiring diagram): Monitoring one guard door: If only one magnetic safety sensor is connected to S1, the terminals S22, S32 and C of S2 must be bridged. | TOL_VOLT_OPERAT_DC_MAX: 15 | Note (applications): Safety sensor | Depth: 110 | Tightening torque of Clips: 0.6 | Electrical power consumption: 2.4 | Stop-Category: 0 | Voltage, Utilisation category AC-15: 230 | ACE reference article number: 193481 | Indicated operating states: Authorised operation | Utilisation category DC-12: 24_0.1

More Schmersal Products from Glorient

In addition to AES 1112 24 VDC, Glorient also supplies:

SLC440-ER-1130-30-H1 Order No: 103039666
G50-035T22/22Y Order No: 101166503
TR 231-01Y-1957 4,5M Order No: 101114308
BDF200-LMGN-11-DTGN-DTWH-DTBK Order No: 103008031
MSP 452-11/11Y-2186-1 Order No: 101184272
G150-220T04Y-1601-2-2281-2 Order No: 103013006
T4V7H 336-20Z-M20-1058/2138 Order No: 151172676
A-K4P-M8-S-W-2M-GY-1-X-X-4 Order No: 103011348
DPN70SW Order No: 101006981
SVE1-Z/128-24VDC Order No: 103044483
SHGV/EKM137 Order No: 103048105
SVE3/204/204/204-24VDC Order No: 101197526
ESS21S1/EKM151 Order No: 103050285
TS 335-20Z-ST Order No: 153002581
Z1R 236-02Z-M16-U270 Order No: 151177539
SHGV/B01/303+BOW Order No: 101198420
MD 441-11Y-M20-RMS Order No: 101168995
ZS 236-02Z-2107 Order No: 151115831
TKF/S.S.R/90230VAC Order No: 101020679
BETAETIGER AZ/AZM 415-B30-05 Order No: 101139957
PS216L-T11-K230-U4 Order No: 103032672
ZUBEHOER KAPPE TYP C-2562 Order No: 103002945
SLC445-ER-0570-30-01 Order No: 103005408
NDAN6WS Order No: 101169824
AZ 16-03ZIB1-M16-2024 Order No: 101150057
SHGV/L01/40+BOW Order No: 103032971
AZM 161SK-12/12RIED/TU-024-B6R Order No: 101217662
T3K 236-02Z-M20-U180 Order No: 151166173
MH 302-11Y-M16 Order No: 101168077
EMLGN Order No: 101006462

Related Guides

Gross weight122 g
Net weight122 g
Ambient temperature+0 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum+0 °C
StandardsEN IEC 60947-5-3
CertificatescULus
Housing materialGlass-fibre reinforced thermoplastic, ventilated
EAN (European Article Number)4030661059259
Mission time20
Mechanical lifetime, minimum10,000,000
Thermal test current4 A
Cable section, maximum2.5 mm²
Material of the contacts, electricalAgCdO
Number of safety contacts1
Resistance to vibrations10...55 Hz, Amplitude 0.35 mm, ± 15 %
Storage and transport temperature-25 ... +70 °C
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
MountingSnaps onto standard DIN rail to EN 60715
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Degree of pollution2
Other ParametersCurrent, Utilisation category DC-12: 0.1 | Switching capacity, maximum: 250 | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Climatic stress: BG-GS-ET-14 | Drop-out delay in case of emergency, typically: 20 | Current, Utilisation category DC-13: 2 | Integral system diagnostics, status: Yes | Reset after disconnection of supply voltage : Yes | Terminal designations: IEC/EN 60947-1 | Rated control voltage at DC, maximum: 27.6 | Cable section: 2.5 mm² | Height: 75 | Restistance to shock: 30 g / 11 ms | Voltage, Utilisation category DC-12: 24 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Pull-in delay at automatic start, maximum, typically: 100 | Conduction resistance, maximum: 40 | Number of normally open (NO): 1 | Automatic reset function: Yes | Number of LEDs: 1 | Switching capacity, minimum: 10 | Operating voltage: 24 VDC -15 % / +15 % | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 2 A | Notice: for max. 50,000 switching cycles/year and max. 80% contact load | Terminal (mechanical): Screw terminals | IP Degree of protection of the installation space: IP54 | Drop-out delay in case of power failure, typically: 80 | Allowed type of cable: solid single-wire | Rated operating voltage: 24 VDC ± 15 % | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 3 A | Number of normally closed (NC): 2 | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | Pull-in delay at RESET, typically: 20 | Safety Integrity Level (SIL), suitable for applications in: 1 | IP Degree of protection of the enclosure: IP40 | PFH value: 1.14 x 10⁻⁶ | TOL_VOLT_OPERAT_DC_MIN: -15 | Width: 22.5 | Note (Contact resistance): in new state | Category: 1 | Performance Level, up to: c | Voltage type: DC | Current, Utilisation category AC-15: 3 | Note (Wiring diagram): Monitoring one guard door: If only one magnetic safety sensor is connected to S1, the terminals S22, S32 and C of S2 must be bridged. | TOL_VOLT_OPERAT_DC_MAX: 15 | Note (applications): Safety sensor | Depth: 110 | Tightening torque of Clips: 0.6 | Electrical power consumption: 2.4 | Stop-Category: 0 | Voltage, Utilisation category AC-15: 230 | ACE reference article number: 193481 | Indicated operating states: Authorised operation | Utilisation category DC-12: 24_0.1