AZM 170-11ZRIA-B6R 24VAC/DC

Schmersal AZM 170-11ZRIA-B6R 24VAC/DC

Model: AZM 170-11ZRIA-B6R 24VAC/DC
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 23 views

Products Introduction

Schmersal AZM 170-11ZRIA-B6R 24VAC/DC (Order No: 101140807) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient tempera...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM 170-11ZRIA-B6R 24VAC/DC, Order No: 101140807. Competitive pricing, fast quotation.

Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.

More Schmersal Products from Glorient

In addition to AZM 170-11ZRIA-B6R 24VAC/DC, Glorient also supplies:

SHGV/EKM59 Order No: 103009686
EX-Z4V7H 355-11Z-3G/D Order No: 101199535
PS315-T12-ST-H310 Order No: 103030670
S-K4P-M12-S-W-X-X-X-X-A-1 Order No: 101209978
SVE1/199-24VDC Order No: 101197240
BNS 300-01ZG 1,5M Order No: 101136217
TA 471-02/02Y Order No: 101061079
SLC440AS-E-1210-30 Order No: 103007519
TD 422-01Y-2186 Order No: 101136229
SLB240-E-4-LST Order No: 103013552
PS316-Z11-H300-U2 Order No: 103032132
BNS 40S-12ZG-C 3,0M Order No: 103000642
PS216-Z11-R200 Order No: 103015003
M. 471-21/21Y Order No: 101061176
TR 336-11Z-ST-3142-1 Order No: 153051283
SDS1/SDS2/EKM38 Order No: 103046486
WSCN21 Order No: 101007329
BDF200-NH-11-LTRD-LTGN-LTBU Order No: 103000314
SVE1/SR/143WS/RT-3Ö-24VDC Order No: 103016685
T2FH 232-22/22 Order No: 151181587
SVM1/SR/57-10/210RT/RT/E Order No: 101214429
TL 441-11Y-T Order No: 101059315
GEE15 Order No: 101008828
SHGV-Z/EKM108 Order No: 103037484
PS-K210 Order No: 103010962
AZM 415-02/02ZPKA 110VAC Order No: 101194276
SHGV/B01/160+BO Order No: 101198133

Related Guides

Typical Applications

Schmersal safety switchgear is widely used in machine guarding and process safety applications, including CNC machining centres, robotic cell fencing, packaging and bottling lines, material handling equipment, press and forming machinery, and automated assembly stations. Choosing the correct interlock or position switch with the right contact rating and coding level is essential to meeting your machine's PL or SIL requirements.

Frequently Asked Questions

Is this Schmersal product 100% genuine?

Yes. All Schmersal products we supply are 100% genuine and new in original factory packing, sourced from authorised supply channels with full factory warranty.

Does this Schmersal model have positive-break safety contacts?

Schmersal safety switches use positive-break (Zwangsöffnung) contacts designed to EN 60947-5-1, which guarantee contact separation even if the actuator is forced out or the spring fails. This is the core requirement for safety circuits rated up to PL e according to EN ISO 13849-1.

How do I get a quotation and lead time?

Send us the part number through the quote form and our team will respond within 24 hours with pricing, stock availability and estimated delivery time.

Gross weight315 g
Net weight315 g
Ambient temperature-25 ... +70 °C
Ambient temperature, maximum1000078497 °C
Ambient temperature, minimum-25 °C
StandardsEN ISO 13849-1
IP Degree of protectionIP67
CertificatescULus, CCC
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661433530
Mission time20
TerminationIDC method of termination
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching element1 NO contact, 1 NC contacts
Switching principleslow action, positive break NC contact
Width of sensor90 mm
Thermal test current6 A
Cable section, maximum1 mm²
Height of sensor84 mm
Material of the contacts, electricalSilver
Utilisation category DC-1324 VDC / 4 A
Max. fuse rating6 A gG D-fuse
Utilisation category AC-15230 VAC / 4 A
Maximum switching frequency1,000 Hz
Cable section, minimum0.75 mm²
Number of safety contacts1 / 2 / 3
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteTorx T10
Number of auxiliary contacts1
TracepartsYes
Storage and transport temperature-25 ... +85 °C
Scope of deliveryThe actuator is included in the scope of delivery
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
MountingScrews
Note (General)This type termination (IDC) method enables simple connetion of flexible conductors without the need for the use of conductor ferrules
Degree of pollution3
Protection classII
Other ParametersOvervoltage category: III | Voltage, Utilisation category DC-13: 24 | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Voltage, Utilisation category AC-15: 230 | Test pulse interval, minimum: 50 | Electrical power consumption, maximum: 12 | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Positive break force per NC contact, minimum: 8.5 | Power to lock: Yes | Working principle: electromechanical | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | Latching force: 30 N | CADENAS: Yes | Type of the fixing screws: 2x M4 | Note (Manual release): bottom | Current, Utilisation category DC-13: 4 | Positive break travel: 11 | Material of the actuator: Stainless steel | Allowed type of cable: solid single-wire | Note (Switching element): Change-over contact with double break, type Zb or 2 NC or 3 NC or 4 NC contacts, with galvanically separated contact bridges | Coding: Individual coding | Cable entry: 1 x M20 x 1,5 | Actuating radius, minimum: 50 | Current, Utilisation category AC-15: 4 | Positive break force, minimum: 8.5 | Coding level according to EN ISO 14119: High | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Manual release: Yes | Cable section: 0.75 mm² ... 1 mm² | Category: 3 | Number of actuating directions: 2 | Note (applications): removable guard | Permissible installation altitude above sea level, maximum: 2,000 | Tightening torque of the fastening screws for the housing cover, minimum: 0.7