Schmersal AZM 170-02ZRI-ST-B6L 24VAC/DC (Order No: 101144373) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient tempe...
Glorient offers competitive supply of Schmersal AZM 170-02ZRI-ST-B6L 24VAC/DC, Order No: 101144373. Competitive pricing, fast quotation.
Schmersal AZM 170-02ZRI-ST-B6L 24VAC/DC - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal AZM 170-02ZRI-ST-B6L 24VAC/DC is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 297 g |
| Net weight | 297 g |
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000078495 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661133140 |
| Mission time | 20 |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 30 mm |
| Switching element | 2 NC contact |
| Switching principle | slow action, positive break NC contact |
| Width of sensor | 108 mm |
| Thermal test current | 4 A |
| Height of sensor | 75.5 mm |
| Material of the contacts, electrical | Silver |
| Utilisation category DC-13 | 24 VDC / 4 A |
| Max. fuse rating | 4 A gG D-fuse |
| Utilisation category AC-15 | 230 VAC / 4 A |
| Maximum switching frequency | 1,000 Hz |
| Number of safety contacts | 2 |
| Required rated short-circuit current | 1,000 A |
| Actuating speed, maximum | 2 m/s |
| Note | Torx T10 |
| Number of auxiliary contacts | 1 |
| Traceparts | Yes |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | The actuator is included in the scope of delivery |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Mounting | Screws |
| Note (General) | Actuating radius adjustable to minimum 50 mm, using a hexagonal key wrench AF 2 mm (a) |
| Degree of pollution | 3 |
| Protection class | II |
| Other Parameters | Overvoltage category: III | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Test pulse interval, minimum: 50 | Electrical power consumption, maximum: 12 | Power to unlock: Yes | Cable section: 0.75 mm² ... 1 mm² | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Positive break force per NC contact, minimum: 8.5 | Voltage, Utilisation category DC-13: 24 | Working principle: electromechanical | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | CADENAS: Yes | Type of the fixing screws: 2x M4 | Latching force: 30 | Voltage, Utilisation category AC-15: 230 | Positive break travel: 11 | Material of the actuator: Stainless steel | Note (Switching element): Change-over contact with double break, type Zb or 2 NC or 3 NC or 4 NC contacts, with galvanically separated contact bridges | Coding: Individual coding | Actuating radius, minimum: 50 | Current, Utilisation category AC-15: 4 | Coding level according to EN ISO 14119: High | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Manual release: Yes | Category: 3 | Number of actuating directions: 2 | Note (applications): removable guard | Positive break force, minimum: 17 | Current, Utilisation category DC-13: 4 | Permissible installation altitude above sea level, maximum: 2,000 | Connector position : Bottom | Note (Manual release): For manual release using M5 triangular key, available as accessory | Tightening torque of the fastening screws for the housing cover, minimum: 0.7 |
In addition to AZM 170-02ZRI-ST-B6L 24VAC/DC, Glorient also supplies:
| Gross weight | 297 g |
| Net weight | 297 g |
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000078495 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661133140 |
| Mission time | 20 |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 30 mm |
| Switching element | 2 NC contact |
| Switching principle | slow action, positive break NC contact |
| Width of sensor | 108 mm |
| Thermal test current | 4 A |
| Height of sensor | 75.5 mm |
| Material of the contacts, electrical | Silver |
| Utilisation category DC-13 | 24 VDC / 4 A |
| Max. fuse rating | 4 A gG D-fuse |
| Utilisation category AC-15 | 230 VAC / 4 A |
| Maximum switching frequency | 1,000 Hz |
| Number of safety contacts | 2 |
| Required rated short-circuit current | 1,000 A |
| Actuating speed, maximum | 2 m/s |
| Note | Torx T10 |
| Number of auxiliary contacts | 1 |
| Traceparts | Yes |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | The actuator is included in the scope of delivery |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Mounting | Screws |
| Note (General) | Actuating radius adjustable to minimum 50 mm, using a hexagonal key wrench AF 2 mm (a) |
| Degree of pollution | 3 |
| Protection class | II |
| Other Parameters | Overvoltage category: III | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Test pulse interval, minimum: 50 | Electrical power consumption, maximum: 12 | Power to unlock: Yes | Cable section: 0.75 mm² ... 1 mm² | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Positive break force per NC contact, minimum: 8.5 | Voltage, Utilisation category DC-13: 24 | Working principle: electromechanical | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | CADENAS: Yes | Type of the fixing screws: 2x M4 | Latching force: 30 | Voltage, Utilisation category AC-15: 230 | Positive break travel: 11 | Material of the actuator: Stainless steel | Note (Switching element): Change-over contact with double break, type Zb or 2 NC or 3 NC or 4 NC contacts, with galvanically separated contact bridges | Coding: Individual coding | Actuating radius, minimum: 50 | Current, Utilisation category AC-15: 4 | Coding level according to EN ISO 14119: High | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Manual release: Yes | Category: 3 | Number of actuating directions: 2 | Note (applications): removable guard | Positive break force, minimum: 17 | Current, Utilisation category DC-13: 4 | Permissible installation altitude above sea level, maximum: 2,000 | Connector position : Bottom | Note (Manual release): For manual release using M5 triangular key, available as accessory | Tightening torque of the fastening screws for the housing cover, minimum: 0.7 |