Schmersal CSS 14-34-S-D-M-ST (Order No: 101181063) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +70 °C; Ambien...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal CSS 14-34-S-D-M-ST, Order No: 101181063. Competitive pricing, fast quotation.

Schmersal CSS 14-34-S-D-M-ST - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal CSS 14-34-S-D-M-ST is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight140 g
Net weight140 g
Ambient temperature-25 ... +70 °C
Ambient temperature, maximum+70 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661314877
Mission time20
TerminationConnector plug M12, 8-pole
Length of sensor35 mm
Width of sensor27 mm
Height of sensor108.2 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Housing construction formBlock
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classII
Other ParametersNumber of fail-safe digital outputs: 2 | ACE reference article number: 164192 | PIN 6: X2 Safety input 2 | Switching distance actuator: Actuator CST 180-1 / CST 180-2: 13 mm (ensured switch distance OFF Sar) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN without function | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Duration of risk, maximum: 60 | Current derating: Ambient temperature -25°C … +65°C: ≤ 0.25 A | Cross-circuit detection: Yes | Voltage, Utilisation category DC-12: 24 | Recommended safety switchgear: SRB-E-301ST | Operating current: 600 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | PIN 2: X1 Safety input 1 | Design of control elements: p-type | Protection class (Operating resource): 2 | Number of series-wiring of sensors: 31 | Diagnostic output: Yes | Absicherung des Sicherheitsausganges: short-circuit proof | Utilisation category DC-12: 24 VDC / 0.25 A | EMC rating: IEC 61000-6-2 | PIN 1: 1A1 Ue: (1) | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | PFH value: 3.60 x 10⁻⁹ | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Category: 4 | Recommendation (actuator): CST 34-S-3 | Number of LEDs: 3 | Actuating panels: lateral | PIN 4: Y1 Safety output 1 | Cable section: 8 mm² | Switching frequency, approx.: 3 | Cascadable: Yes | Safety Integrity Level (SIL), suitable for applications in: 3 | Number of semi-conductor outputs with signaling function: 1 | Active area: Glass-fibre, reinforced thermoplastic | PIN 5: OUT Diagnostic output OUT | PIN 7: Y2 Safety output 2 | Note (Electrical data, Fuse rating): (Circuit breaker) | Interfering radiation: IEC 61000-6-4 | Absicherung des Diagnoseausganges: short-circuit proof | Hysteresis (Switching distance), maximum: 1.5 | Overvoltage category: 3 | Reaction time, maximum: 30 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e

More Schmersal Products from Glorient

In addition to CSS 14-34-S-D-M-ST, Glorient also supplies:

E-KB9WS/L00841039 Order No: 101218388
SEWL103S Order No: 101019952
BNS 33-02Z-2187 5,0M Order No: 101137364
SHGV/B01/191+BOWR Order No: 103032344
PS215-Z11-N200 Order No: 103014972
EX-TS335-11Y Order No: 151211813
EFK10.3 Order No: 101022277
BS-H50-110-RKS Order No: 153028034
E-KB9WS/L00841107 Order No: 101218423
T4VH 336-11Z-M20 Order No: 151158892
SHGV/LD1/211/31+BOF/HIS.1 Order No: 101213401
T. 441-11Y-1801 Order No: 101209137
EDLRGN Order No: 101006452
TV1H 236-02Z-M20 Order No: 151168171
SLC440COM-ER-0490-35-1700 Order No: 103040530
G50-025M22/11Y-1601-3 Order No: 101178208
SLC440COM-ER-0330-35-1700 Order No: 103040528
ACC-CGLD-M20-P Order No: 103006013
PS316-T11-K370 Order No: 103015157
RDTWS/514 Order No: 101204428
Z4V7H 335-02Z-1058/2138 Order No: 151183949
TR 256-11ZUE Order No: 151145287
G34930000 230 Order No: 103010211
SLC440-ER-0650-30 Order No: 101216719
AZM201Z-ST-T-1P2PW-2965-1 Order No: 103025499
SLC440-ER-1450-30-H1 Order No: 103039670
PS-R210 Order No: 103032722

Related Guides

Gross weight140 g
Net weight140 g
Ambient temperature-25 ... +70 °C
Ambient temperature, maximum+70 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661314877
Mission time20
TerminationConnector plug M12, 8-pole
Length of sensor35 mm
Width of sensor27 mm
Height of sensor108.2 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Housing construction formBlock
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classII
Other ParametersNumber of fail-safe digital outputs: 2 | ACE reference article number: 164192 | PIN 6: X2 Safety input 2 | Switching distance actuator: Actuator CST 180-1 / CST 180-2: 13 mm (ensured switch distance OFF Sar) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN without function | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Duration of risk, maximum: 60 | Current derating: Ambient temperature -25°C … +65°C: ≤ 0.25 A | Cross-circuit detection: Yes | Voltage, Utilisation category DC-12: 24 | Recommended safety switchgear: SRB-E-301ST | Operating current: 600 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | PIN 2: X1 Safety input 1 | Design of control elements: p-type | Protection class (Operating resource): 2 | Number of series-wiring of sensors: 31 | Diagnostic output: Yes | Absicherung des Sicherheitsausganges: short-circuit proof | Utilisation category DC-12: 24 VDC / 0.25 A | EMC rating: IEC 61000-6-2 | PIN 1: 1A1 Ue: (1) | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | PFH value: 3.60 x 10⁻⁹ | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Category: 4 | Recommendation (actuator): CST 34-S-3 | Number of LEDs: 3 | Actuating panels: lateral | PIN 4: Y1 Safety output 1 | Cable section: 8 mm² | Switching frequency, approx.: 3 | Cascadable: Yes | Safety Integrity Level (SIL), suitable for applications in: 3 | Number of semi-conductor outputs with signaling function: 1 | Active area: Glass-fibre, reinforced thermoplastic | PIN 5: OUT Diagnostic output OUT | PIN 7: Y2 Safety output 2 | Note (Electrical data, Fuse rating): (Circuit breaker) | Interfering radiation: IEC 61000-6-4 | Absicherung des Diagnoseausganges: short-circuit proof | Hysteresis (Switching distance), maximum: 1.5 | Overvoltage category: 3 | Reaction time, maximum: 30 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e