Schmersal CSS 14-34-S-D-M-ST (Order No: 101181063) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +70 °C; Ambien...
Glorient offers competitive supply of Schmersal CSS 14-34-S-D-M-ST, Order No: 101181063. Competitive pricing, fast quotation.
Schmersal CSS 14-34-S-D-M-ST - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal CSS 14-34-S-D-M-ST is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 140 g |
| Net weight | 140 g |
| Ambient temperature | -25 ... +70 °C |
| Ambient temperature, maximum | +70 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 4030661314877 |
| Mission time | 20 |
| Termination | Connector plug M12, 8-pole |
| Length of sensor | 35 mm |
| Width of sensor | 27 mm |
| Height of sensor | 108.2 mm |
| Utilisation category DC-13 | 24 VDC / 0.25 A |
| Required rated short-circuit current | 100 A |
| Traceparts | Yes |
| Housing construction form | Block |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Degree of pollution | 3 |
| Protection class | II |
| Other Parameters | Number of fail-safe digital outputs: 2 | ACE reference article number: 164192 | PIN 6: X2 Safety input 2 | Switching distance actuator: Actuator CST 180-1 / CST 180-2: 13 mm (ensured switch distance OFF Sar) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN without function | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Duration of risk, maximum: 60 | Current derating: Ambient temperature -25°C … +65°C: ≤ 0.25 A | Cross-circuit detection: Yes | Voltage, Utilisation category DC-12: 24 | Recommended safety switchgear: SRB-E-301ST | Operating current: 600 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | PIN 2: X1 Safety input 1 | Design of control elements: p-type | Protection class (Operating resource): 2 | Number of series-wiring of sensors: 31 | Diagnostic output: Yes | Absicherung des Sicherheitsausganges: short-circuit proof | Utilisation category DC-12: 24 VDC / 0.25 A | EMC rating: IEC 61000-6-2 | PIN 1: 1A1 Ue: (1) | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | PFH value: 3.60 x 10⁻⁹ | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Category: 4 | Recommendation (actuator): CST 34-S-3 | Number of LEDs: 3 | Actuating panels: lateral | PIN 4: Y1 Safety output 1 | Cable section: 8 mm² | Switching frequency, approx.: 3 | Cascadable: Yes | Safety Integrity Level (SIL), suitable for applications in: 3 | Number of semi-conductor outputs with signaling function: 1 | Active area: Glass-fibre, reinforced thermoplastic | PIN 5: OUT Diagnostic output OUT | PIN 7: Y2 Safety output 2 | Note (Electrical data, Fuse rating): (Circuit breaker) | Interfering radiation: IEC 61000-6-4 | Absicherung des Diagnoseausganges: short-circuit proof | Hysteresis (Switching distance), maximum: 1.5 | Overvoltage category: 3 | Reaction time, maximum: 30 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |
In addition to CSS 14-34-S-D-M-ST, Glorient also supplies:
| Gross weight | 140 g |
| Net weight | 140 g |
| Ambient temperature | -25 ... +70 °C |
| Ambient temperature, maximum | +70 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 4030661314877 |
| Mission time | 20 |
| Termination | Connector plug M12, 8-pole |
| Length of sensor | 35 mm |
| Width of sensor | 27 mm |
| Height of sensor | 108.2 mm |
| Utilisation category DC-13 | 24 VDC / 0.25 A |
| Required rated short-circuit current | 100 A |
| Traceparts | Yes |
| Housing construction form | Block |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Degree of pollution | 3 |
| Protection class | II |
| Other Parameters | Number of fail-safe digital outputs: 2 | ACE reference article number: 164192 | PIN 6: X2 Safety input 2 | Switching distance actuator: Actuator CST 180-1 / CST 180-2: 13 mm (ensured switch distance OFF Sar) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN without function | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Duration of risk, maximum: 60 | Current derating: Ambient temperature -25°C … +65°C: ≤ 0.25 A | Cross-circuit detection: Yes | Voltage, Utilisation category DC-12: 24 | Recommended safety switchgear: SRB-E-301ST | Operating current: 600 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | PIN 2: X1 Safety input 1 | Design of control elements: p-type | Protection class (Operating resource): 2 | Number of series-wiring of sensors: 31 | Diagnostic output: Yes | Absicherung des Sicherheitsausganges: short-circuit proof | Utilisation category DC-12: 24 VDC / 0.25 A | EMC rating: IEC 61000-6-2 | PIN 1: 1A1 Ue: (1) | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | PFH value: 3.60 x 10⁻⁹ | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Category: 4 | Recommendation (actuator): CST 34-S-3 | Number of LEDs: 3 | Actuating panels: lateral | PIN 4: Y1 Safety output 1 | Cable section: 8 mm² | Switching frequency, approx.: 3 | Cascadable: Yes | Safety Integrity Level (SIL), suitable for applications in: 3 | Number of semi-conductor outputs with signaling function: 1 | Active area: Glass-fibre, reinforced thermoplastic | PIN 5: OUT Diagnostic output OUT | PIN 7: Y2 Safety output 2 | Note (Electrical data, Fuse rating): (Circuit breaker) | Interfering radiation: IEC 61000-6-4 | Absicherung des Diagnoseausganges: short-circuit proof | Hysteresis (Switching distance), maximum: 1.5 | Overvoltage category: 3 | Reaction time, maximum: 30 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |