Schmersal CSS 14-34-S-SD-M-ST (Order No: 101181066) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +70 °C; Ambie...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal CSS 14-34-S-SD-M-ST, Order No: 101181066. Competitive pricing, fast quotation.

Schmersal CSS 14-34-S-SD-M-ST - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal CSS 14-34-S-SD-M-ST is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight140 g
Net weight140 g
Ambient temperature-25 ... +70 °C
Ambient temperature, maximum+70 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661314891
Mission time20
TerminationConnector plug M12, 8-pole
Length of sensor35 mm
Width of sensor27 mm
Height of sensor108.2 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Housing construction formBlock
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classII
Other ParametersNumber of fail-safe digital outputs: 2 | PIN 6: X2 Safety input 2 | Switching distance actuator: Actuator CST 180-1 / CST 180-2: 13 mm (ensured switch distance OFF Sar) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Duration of risk, maximum: 60 | Current derating: Ambient temperature -25°C … +65°C: ≤ 0.25 A | Cross-circuit detection: Yes | Recommended safety switchgear: SRB-E-301ST | Design of control elements: short-circuit proof, p-type | Operating current: 600 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | PIN 2: X1 Safety input 1 | Serial diagnostics: Yes | Protection class (Operating resource): 2 | Wiring capacitance: 50 | Number of series-wiring of sensors: 31 | Diagnostic output: Yes | Absicherung des Sicherheitsausganges: short-circuit proof | Utilisation category DC-12: 24 VDC / 0.25 A | EMC rating: IEC 61000-6-2 | PIN 1: 1A1 Ue: (1) | Repeat accuracy R: 0.5 | Voltage, Utilisation category DC-12: 24 | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | PFH value: 3.60 x 10⁻⁹ | Installation conditions (mechanical): not flush | Rated operating current (safety outputs): 250 | Category: 4 | Recommendation (actuator): CST 34-S-3 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Number of LEDs: 3 | Actuating panels: lateral | PIN 4: Y1 Safety output 1 | Cable section: 8 mm² | PIN 5: SD serial diagnostic output | Switching frequency, approx.: 3 | Cascadable: Yes | Safety Integrity Level (SIL), suitable for applications in: 3 | Designation, Serial diagnostic SD: OUT | Number of semi-conductor outputs with signaling function: 1 | Active area: Glass-fibre, reinforced thermoplastic | ACE reference article number: 164183 | PIN 7: Y2 Safety output 2 | Note (Electrical data, Fuse rating): (Circuit breaker) | Current, Utilisation category DC-13: 0.25 | Interfering radiation: IEC 61000-6-4 | Absicherung des Diagnoseausganges: short-circuit proof | Hysteresis (Switching distance), maximum: 1.5 | Current, Utilisation category DC-12: 0.25 | PIN 8: IN serial diagnostic input | Overvoltage category: 3 | Reaction time, maximum: 30 | Output current, (fail-safe output), maximum: 0.25 | Operation current: 150 | Performance Level, up to: e

More Schmersal Products from Glorient

In addition to CSS 14-34-S-SD-M-ST, Glorient also supplies:

AZM 161SK-12/12RIA-024-B1 Order No: 101211547
ACC-RSS260-MK Order No: 103005469
E-KB9WS/L00841182 Order No: 101218481
NDTGR/WS/506H Order No: 101215637
EX-BNS 33-02ZG-2187-3GD 10M Order No: 103050104
BDF200-NHK-11-LTYE-LTBU-LMGN Order No: 101215614
AZ 15 ZVK-1476-5/2036-4 Order No: 101160067
ZV7H 235-02Z-2138 Order No: 151149221
WKTE52 Order No: 101019461
EX-BS655-Z22-DN-2D Order No: 153038067
#TRA.NPN DSS4160V-7 DID Order No: 103048428
SHGV/LD1/161/61+BOW Order No: 103010266
BDF200-NHK-11-SWS20-LMGN-LTWH Order No: 103003570
EX-BNS 250-12Z-2187-3GD 5M Order No: 103045524
SVM1/41-10/141/A Order No: 101213519
BNS 36 STW-AS-R Order No: 101194958
MKSC32/WKT-19.4 Order No: 101196044
BN 20-10Z-M16 Order No: 101172882
BETAETIGUNGSHEBEL 8R KPL Order No: 101066472
ZR 236-11Z-2042 Order No: 151185091
PS316-Z11-ST-S300 Order No: 103037627
BNS 33-12Z-2187 2,0M Order No: 101154627
M 6820-11-6E EINSATZ Order No: 101061957
EX-SVE1/103-24VDC Order No: 103015365
G150-050T22/22Y Order No: 101063410
SHGV/ESS21S2/903/103 Order No: 101215589
TL 064-12Y Order No: 101060754
MS-1101 Order No: 103014167

Related Guides

Gross weight140 g
Net weight140 g
Ambient temperature-25 ... +70 °C
Ambient temperature, maximum+70 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661314891
Mission time20
TerminationConnector plug M12, 8-pole
Length of sensor35 mm
Width of sensor27 mm
Height of sensor108.2 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Housing construction formBlock
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classII
Other ParametersNumber of fail-safe digital outputs: 2 | PIN 6: X2 Safety input 2 | Switching distance actuator: Actuator CST 180-1 / CST 180-2: 13 mm (ensured switch distance OFF Sar) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Duration of risk, maximum: 60 | Current derating: Ambient temperature -25°C … +65°C: ≤ 0.25 A | Cross-circuit detection: Yes | Recommended safety switchgear: SRB-E-301ST | Design of control elements: short-circuit proof, p-type | Operating current: 600 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | PIN 2: X1 Safety input 1 | Serial diagnostics: Yes | Protection class (Operating resource): 2 | Wiring capacitance: 50 | Number of series-wiring of sensors: 31 | Diagnostic output: Yes | Absicherung des Sicherheitsausganges: short-circuit proof | Utilisation category DC-12: 24 VDC / 0.25 A | EMC rating: IEC 61000-6-2 | PIN 1: 1A1 Ue: (1) | Repeat accuracy R: 0.5 | Voltage, Utilisation category DC-12: 24 | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | PFH value: 3.60 x 10⁻⁹ | Installation conditions (mechanical): not flush | Rated operating current (safety outputs): 250 | Category: 4 | Recommendation (actuator): CST 34-S-3 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Number of LEDs: 3 | Actuating panels: lateral | PIN 4: Y1 Safety output 1 | Cable section: 8 mm² | PIN 5: SD serial diagnostic output | Switching frequency, approx.: 3 | Cascadable: Yes | Safety Integrity Level (SIL), suitable for applications in: 3 | Designation, Serial diagnostic SD: OUT | Number of semi-conductor outputs with signaling function: 1 | Active area: Glass-fibre, reinforced thermoplastic | ACE reference article number: 164183 | PIN 7: Y2 Safety output 2 | Note (Electrical data, Fuse rating): (Circuit breaker) | Current, Utilisation category DC-13: 0.25 | Interfering radiation: IEC 61000-6-4 | Absicherung des Diagnoseausganges: short-circuit proof | Hysteresis (Switching distance), maximum: 1.5 | Current, Utilisation category DC-12: 0.25 | PIN 8: IN serial diagnostic input | Overvoltage category: 3 | Reaction time, maximum: 30 | Output current, (fail-safe output), maximum: 0.25 | Operation current: 150 | Performance Level, up to: e