Schmersal EX-BNS 303-12Z-2187-3G/D (Order No: 101185026) is a genuine explosion-proof switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +70 ...
Glorient offers competitive supply of Schmersal EX-BNS 303-12Z-2187-3G/D, Order No: 101185026. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to EX-BNS 303-12Z-2187-3G/D, Glorient also supplies:
| Gross weight | 95 g |
| Net weight | 95 g |
| Ambient temperature | -25 ... +70 °C |
| Ambient temperature, maximum | +70 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN ISO 13849-1 |
| IP Degree of protection | IP67 |
| Certificates | ATEX (Konformitätserklärung) |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 4030661333113 |
| Mission time | 20 |
| Termination | cable |
| Length of sensor | 44 mm |
| Switching element | 1 NO contact, 2 NC contacts |
| Switching principle | Reed contacts, Non-contact principle |
| Number of safety contacts | 2 |
| Actuating element | Magnet |
| Housing construction form | Cylinder, thread |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Note (General) | The contact configuration for versions with or without LED is identical. |
| Other Parameters | Recommendation (actuator): BPS 303 | Material of the Cable mantle: PVC | Material of the nuts: Thermoplastic | Number of cable wires: 6 | Switching frequency, maximum: 5 | Short circuit detection: Yes | Cross-circuit detection: Yes | Recommended safety switchgear: SRB-E-301ST | ISO thread of the sensor: M30 | Restistance to shock: 30 g / 11 ms | Impact energy, maximum: 4 | Number of normally open (NO): 1 | Explosion protection category: 3G | Installation conditions (mechanical): quasi-flush | Wire cross-section: 0.25 | Explosion protection: regulations: EN IEC 60079-0 | width across flats: 36 | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Active area: front side | Scope of delivery of mounting material: 2x nuts M30 x 1.5 | Direction of motion: Head-on to the active surface | Length of cable: 1 | Number of normally closed (NC): 2 | Tightening torque of nuts, maximum: 3 | Switching capacity, maximum: 10 | Traceparts, product ID: 33-22052019-077540 | Switching voltage, maximum: 100 | Manufacturer declaration: ATEX Zone 2 and 22 | Switching current, maximum: 0.4 | Coding: Yes | Explosion protection zones: 22 |