Schmersal AZM 170SK-02/01ZK 24VAC/DC (Order No: 101192841) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient temperat...
Glorient offers competitive supply of Schmersal AZM 170SK-02/01ZK 24VAC/DC, Order No: 101192841. Competitive pricing, fast quotation.
Schmersal AZM 170SK-02/01ZK 24VAC/DC - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal AZM 170SK-02/01ZK 24VAC/DC is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 318 g |
| Net weight | 318 g |
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000078499 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661353944 |
| Mission time | 20 |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 30 mm |
| Switching element | Magnet: 2 NC contacts / Actuator: 1 NC contact |
| Switching principle | slow action, positive break NC contact |
| Width of sensor | 90 mm |
| Cable section, maximum | 1.5 mm² |
| Height of sensor | 100.5 mm |
| Material of the contacts, electrical | Silver |
| Utilisation category DC-13 | 24 VDC / 4 A |
| Max. fuse rating | 6 A gG D-fuse |
| Utilisation category AC-15 | 230 VAC / 4 A |
| Maximum switching frequency | 1,000 Hz |
| Cable section, minimum | 0.25 mm² |
| Number of safety contacts | 3 |
| Required rated short-circuit current | 1,000 A |
| Actuating speed, maximum | 2 m/s |
| Note | Torx T10 |
| Number of auxiliary contacts | 1 / 2 |
| Traceparts | Yes |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Mounting | Screws |
| Degree of pollution | 3 |
| Protection class | II |
| Other Parameters | Overvoltage category: III | Voltage, Utilisation category DC-13: 24 | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Test pulse interval, minimum: 50 | Electrical power consumption, maximum: 12 | Power to unlock: Yes | Note (Switching element): Change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges | Tightening torque of electrical connection, maximum: 0.6 | Test pulse duration, maximum: 5 | Note (Relative humidity): non-condensing | Wire cross-section, minimum: 24 | Positive break force per NC contact, minimum: 8.5 | Coding level according to EN ISO 14119: Low | Latching force: 5 / 30 N | Cable cross-section of the cable glands, minimum: 4 | Working principle: electromechanical | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | Type of the fixing screws: 2x M4 | Current, Utilisation category DC-13: 4 | Positive break travel: 11 | Terminal (mechanical): Screw terminals | Allowed type of cable: solid single-wire | Cable entry: 1 x M20 x 1,5 | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Operating current: 4,000 | Cable cross-section of the cable glands, maximum: 10 | Category: 3 | Number of actuating directions: 2 | Note (applications): removable guard | Positive break force, minimum: 17 | Permissible installation altitude above sea level, maximum: 2,000 | Tightening torque of electrical connection, minimum: 0.4 | Wire cross-section, maximum: 16 | Tightening torque of the fastening screws for the housing cover, minimum: 0.7 |
In addition to AZM 170SK-02/01ZK 24VAC/DC, Glorient also supplies:
| Gross weight | 318 g |
| Net weight | 318 g |
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000078499 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661353944 |
| Mission time | 20 |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 30 mm |
| Switching element | Magnet: 2 NC contacts / Actuator: 1 NC contact |
| Switching principle | slow action, positive break NC contact |
| Width of sensor | 90 mm |
| Cable section, maximum | 1.5 mm² |
| Height of sensor | 100.5 mm |
| Material of the contacts, electrical | Silver |
| Utilisation category DC-13 | 24 VDC / 4 A |
| Max. fuse rating | 6 A gG D-fuse |
| Utilisation category AC-15 | 230 VAC / 4 A |
| Maximum switching frequency | 1,000 Hz |
| Cable section, minimum | 0.25 mm² |
| Number of safety contacts | 3 |
| Required rated short-circuit current | 1,000 A |
| Actuating speed, maximum | 2 m/s |
| Note | Torx T10 |
| Number of auxiliary contacts | 1 / 2 |
| Traceparts | Yes |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Mounting | Screws |
| Degree of pollution | 3 |
| Protection class | II |
| Other Parameters | Overvoltage category: III | Voltage, Utilisation category DC-13: 24 | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Test pulse interval, minimum: 50 | Electrical power consumption, maximum: 12 | Power to unlock: Yes | Note (Switching element): Change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges | Tightening torque of electrical connection, maximum: 0.6 | Test pulse duration, maximum: 5 | Note (Relative humidity): non-condensing | Wire cross-section, minimum: 24 | Positive break force per NC contact, minimum: 8.5 | Coding level according to EN ISO 14119: Low | Latching force: 5 / 30 N | Cable cross-section of the cable glands, minimum: 4 | Working principle: electromechanical | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | Type of the fixing screws: 2x M4 | Current, Utilisation category DC-13: 4 | Positive break travel: 11 | Terminal (mechanical): Screw terminals | Allowed type of cable: solid single-wire | Cable entry: 1 x M20 x 1,5 | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Operating current: 4,000 | Cable cross-section of the cable glands, maximum: 10 | Category: 3 | Number of actuating directions: 2 | Note (applications): removable guard | Positive break force, minimum: 17 | Permissible installation altitude above sea level, maximum: 2,000 | Tightening torque of electrical connection, minimum: 0.4 | Wire cross-section, maximum: 16 | Tightening torque of the fastening screws for the housing cover, minimum: 0.7 |