Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

MZM 100 ST-1P2PW-A

Schmersal MZM 100 ST-1P2PW-A

Model: MZM 100 ST-1P2PW-A
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 16 views

Products Introduction

Schmersal MZM 100 ST-1P2PW-A (Order No: 101199544) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +55 °C; Ambien...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal MZM 100 ST-1P2PW-A, Order No: 101199544. Competitive pricing, fast quotation.

Schmersal MZM 100 ST-1P2PW-A - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal MZM 100 ST-1P2PW-A is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight660 g
Net weight660 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661366593
Mission time20
TerminationConnector M23, 8+1-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor179 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | External wire and device fuse rating: 2 A gG (Connector M23, 8+1-pole) | Working principle: inductive | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Designation, Diagnostic outputs: OUT | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Test pulse interval, minimum: 40 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | CADENAS: Yes | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PIN 9: without function | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Rated operating voltage: 24 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M23, 8+1-pole | Current consumption with magnet ON, average : 350 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | VOLT_TYPE_DIAGN_OUT: DC | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2

More Schmersal Products from Glorient

In addition to MZM 100 ST-1P2PW-A, Glorient also supplies:

BETAETIGUNGSORGAN ZR 332 ERSAT Order No: 131064171
G50-050T04Y-1601-2-1300-1-FL1 Order No: 103007652
EDT.VWS/101 Order No: 101195840
TZFWSP24VDC Order No: 131157873
NDTGN/501D Order No: 101189521
TR 236-11Z-1637 Order No: 151102126
EX-SLC440-ER-0490-14-H Order No: 103047652
AZM150SK-11/02RI-024-B6R Order No: 153032227
RDP40SW/504L Order No: 103006542
BETAETIGUNGSHEBEL 8V KPL. Order No: 101064458
T4K 236-01Z-M16-1924 Order No: 101160563
STW-SL-N-06-4000-2-L2 Order No: 103043708
EX-SLC440-ER-0970-30-H Order No: 103047641
AZM 161SK-12/03RK-024G Order No: 101195904
STW-SL-N-06-990-1-L2 Order No: 103051171
DRN.1RT/B Order No: 101020652
BETAETIGER AZ/AZM 415-B30-05 Order No: 101139957
SVE2/150/150-3Ö-24VDC Order No: 103027410
SHGV/L01/219+BO Order No: 101197900
ESS21S1/EKM185 Order No: 103050339
BNS-B20-12ZG-H 10,0M Order No: 101195975
NSK/V4A/GB Order No: 101183505
SLG440AS-R-0500-02 Order No: 103007552
PS216-Z11-M16-K230 Order No: 103049358
SHGV/LD1/100/61+BOF/HIS.1 Order No: 103050965
ZS 236-11Z-2219 Order No: 151136712
T4V7H 335-02ZH Order No: 151082573
TS 236-11Z-1273 Order No: 101118443

Related Guides

Gross weight660 g
Net weight660 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661366593
Mission time20
TerminationConnector M23, 8+1-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor179 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | External wire and device fuse rating: 2 A gG (Connector M23, 8+1-pole) | Working principle: inductive | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Designation, Diagnostic outputs: OUT | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Test pulse interval, minimum: 40 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | CADENAS: Yes | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PIN 9: without function | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Rated operating voltage: 24 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M23, 8+1-pole | Current consumption with magnet ON, average : 350 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | VOLT_TYPE_DIAGN_OUT: DC | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2