Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

MZM 100 ST2-1P2P-A

Schmersal MZM 100 ST2-1P2P-A

Model: MZM 100 ST2-1P2P-A
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 15 views

Products Introduction

Schmersal MZM 100 ST2-1P2P-A (Order No: 101199622) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +55 °C; Ambien...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal MZM 100 ST2-1P2P-A, Order No: 101199622. Competitive pricing, fast quotation.

Schmersal MZM 100 ST2-1P2P-A - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal MZM 100 ST2-1P2P-A is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight698 g
Net weight698 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661394787
Mission time20
TerminationConnector M12, 8-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor177.5 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Designation, Diagnostic outputs: OUT | External wire and device fuse rating: 2 A gG | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Test pulse interval, minimum: 40 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Rated operating voltage: 24 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Current consumption with magnet ON, average : 350 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | VOLT_TYPE_DIAGN_OUT: DC | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2

More Schmersal Products from Glorient

In addition to MZM 100 ST2-1P2P-A, Glorient also supplies:

SRB100DR Order No: 101186279
SHGV/ESS21S2/107/103 Order No: 101205804
RF10.1 Order No: 101195133
PS216-Z02-N200 Order No: 103031911
AV21LX20U-GB215 Order No: 103028215
BNS 180-11Z 10,0M Order No: 101149430
T3K 236-11Z-M16 Order No: 151104811
SVE1/SR/106BL/GN-24VDC Order No: 103015935
PS216-T12-S200 Order No: 103015024
M 630-11-3-C-E17 Order No: 101061481
BETAETIGUNGSORGAN ZR 332 ERSAT Order No: 131064171
SVM1/53-10/154/E Order No: 103043410
EDP40SW Order No: 101006296
SVE2/100/100-3Ö-24VDC Order No: 103026724
AZM 415-02/11XPKRS 24VAC/DC Order No: 101174583
SHGV/L01/46+BO Order No: 103035343
PS315-Z12-S200 Order No: 103015408
SLC440COM-ER-0890-35-1700 Order No: 103040535
AV15RHKE4X11,5U-1453 Order No: 101056016
ESS21S1/EKM239 Order No: 103050407
ESS32S123/EKM32 Order No: 101204807
VORSATZ AZ 335 HART COATIERT Order No: 101156336
SLG440COM-R-0500-02-1700 Order No: 103040575
PS116-T11-L200-H200 Order No: 103006645
ESS21S1/EKM197 Order No: 103050352
MDP-8.2/BG-133 VERKLEBT Order No: 101191209
TR 236-02Z-1637 Order No: 153002183
SLC440AS-ER-0250-30 Order No: 103007441

Related Guides

Gross weight698 g
Net weight698 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661394787
Mission time20
TerminationConnector M12, 8-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor177.5 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Designation, Diagnostic outputs: OUT | External wire and device fuse rating: 2 A gG | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Test pulse interval, minimum: 40 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Rated operating voltage: 24 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Current consumption with magnet ON, average : 350 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | VOLT_TYPE_DIAGN_OUT: DC | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2