Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

CSS 8-180-2P+D-M-LST 0,2M

Schmersal CSS 8-180-2P+D-M-LST 0,2M

Model: CSS 8-180-2P+D-M-LST 0,2M
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 16 views

Products Introduction

Schmersal CSS 8-180-2P+D-M-LST 0,2M (Order No: 101207896) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +60 °C;...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal CSS 8-180-2P+D-M-LST 0,2M, Order No: 101207896. Competitive pricing, fast quotation.

Schmersal CSS 8-180-2P+D-M-LST 0,2M - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal CSS 8-180-2P+D-M-LST 0,2M is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight85 g
Net weight85 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078659 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatesUKCA
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661372877
Mission time20
Length of sensor92 mm
Utilisation category DC-1324 VDC / 0.5 A
Housing construction formCylinder, thread
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classII
Other ParametersNumber of fail-safe digital outputs: 2 | PIN 3: A2 GND | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | width across flats: 24 | Operating voltage, maximum: 26.4 | Utilisation category DC-12: 24_0.5 | Cross-circuit detection: Yes | Rated operating voltage: 24 VDC | PIN 7: 2 Safety output Y2 | Length of cable: 0.2 | Voltage, Utilisation category DC-12: 24 | Recommended safety switchgear: SRB-E-301ST | Working principle: inductive | Note (Characteristic curve): Soff: Switch-off distance | Restistance to shock: 30 g / 11 ms | Material of the nuts: Glass-fibre, reinforced thermoplastic | Output current, (fail-safe output), maximum: 0.5 | Design of control elements: p-type | Protection class (Operating resource): 2 | Operating voltage: 24 VDC -15 % / +10 % | Hysteresis (Switching distance), maximum: 0.7 | PIN 8: without function | ISO thread of the sensor: M18 | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | PIN 1: 1A1 Ue: (1) | Operating voltage, minimum: 20.4 | Current, Utilisation category DC-12: 0.05 | Note (LED switching conditions display): Multi-coloured LED: Green, Red, Yellow | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | Scope of delivery of mounting material: 2x nuts M18 x 1 | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | PIN 6: X1 Safety input 1 | Rated operating current (safety outputs): 500 | Category: 4 | Recommendation (actuator): CST 180-2 | Operating current: 1,000 | TOL_VOLT_OPERAT_DC_MAX: 10 | Tightening torque of nuts, maximum: 3 | PFH value: 3.57 x 10⁻⁹ | PIN 4: Y1 Safety output 1 | Switching frequency, approx.: 3 | TOL_VOLT_OPERAT_DC_MIN: -15 | Terminal connector, Input/Output: M12 connector, 8 pole | Safety Integrity Level (SIL), suitable for applications in: 3 | Number of semi-conductor outputs with signaling function: 1 | Active area: Glass-fibre, reinforced thermoplastic | Duration of risk, maximum: 30 | Voltage type: DC | PIN 5: Signalling output | Number of series-wiring of sensors: 16 | Repeat accuracy R: 0.2 | VOLT_TYPE_DIAGN_OUT: DC | Absicherung des Diagnoseausganges: short-circuit proof | PIN 2: X2 Safety input 2 | Absicherung des Sicherheitsausganges: short-circuit proof, p-type | Overvoltage category: 3 | Switch distance, typical: 8 | Reaction time, maximum: 30 | Performance Level, up to: e

More Schmersal Products from Glorient

In addition to CSS 8-180-2P+D-M-LST 0,2M, Glorient also supplies:

SVE3/101/101/101-3Ö-230VAC Order No: 103001957
EDP40.VGN Order No: 101006179
TFH 232-22UEDR Order No: 101192630
SHGV/ESS21S2/50/103 Order No: 101205772
E-KB9WS/L00841109 Order No: 101218425
SHGV/B01/304+BOW Order No: 103039327
SEWLF102.1 Order No: 101019965
NZSO/1/V4A Order No: 101184036
A-K4P-M8-S-W-5M-GY-1-X-X-4 Order No: 103011349
MS 017-22E EINSATZ Order No: 131064354
NDLWS/SYM-D16 Order No: 101189986
SEK022 Order No: 101020024
E-KB9WS/L00841126 Order No: 101218436
AZ 17-02ZI-ST B5 Order No: 101144083
T. 250-02Z Order No: 101089591
BDF200-ST1-AS-B-LTWH-LTYE-B Order No: 103000669
MR 441-11Y-A-T-M20-2037 Order No: 101160083
EDRR-1.1 SET Order No: 101204172
SHGV/R01/103+BOF/HIS.1 Order No: 103034680
BNS 33-02Z-2516 Order No: 101181839
SHGV/B01/258+BOW Order No: 103039149
DLH6RT/RT Order No: 101007630
E-KB9WS/L00841172 Order No: 101218474
SMS-5-500-1800 Order No: 103048682
SVE2/53/53-3Ö-24VDC Order No: 101197631
DTN-8 Order No: 101000616
Z4VH 332-11Y-1225 Order No: 131054581

Related Guides

Gross weight85 g
Net weight85 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078659 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatesUKCA
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661372877
Mission time20
Length of sensor92 mm
Utilisation category DC-1324 VDC / 0.5 A
Housing construction formCylinder, thread
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classII
Other ParametersNumber of fail-safe digital outputs: 2 | PIN 3: A2 GND | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | width across flats: 24 | Operating voltage, maximum: 26.4 | Utilisation category DC-12: 24_0.5 | Cross-circuit detection: Yes | Rated operating voltage: 24 VDC | PIN 7: 2 Safety output Y2 | Length of cable: 0.2 | Voltage, Utilisation category DC-12: 24 | Recommended safety switchgear: SRB-E-301ST | Working principle: inductive | Note (Characteristic curve): Soff: Switch-off distance | Restistance to shock: 30 g / 11 ms | Material of the nuts: Glass-fibre, reinforced thermoplastic | Output current, (fail-safe output), maximum: 0.5 | Design of control elements: p-type | Protection class (Operating resource): 2 | Operating voltage: 24 VDC -15 % / +10 % | Hysteresis (Switching distance), maximum: 0.7 | PIN 8: without function | ISO thread of the sensor: M18 | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | PIN 1: 1A1 Ue: (1) | Operating voltage, minimum: 20.4 | Current, Utilisation category DC-12: 0.05 | Note (LED switching conditions display): Multi-coloured LED: Green, Red, Yellow | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | Scope of delivery of mounting material: 2x nuts M18 x 1 | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | PIN 6: X1 Safety input 1 | Rated operating current (safety outputs): 500 | Category: 4 | Recommendation (actuator): CST 180-2 | Operating current: 1,000 | TOL_VOLT_OPERAT_DC_MAX: 10 | Tightening torque of nuts, maximum: 3 | PFH value: 3.57 x 10⁻⁹ | PIN 4: Y1 Safety output 1 | Switching frequency, approx.: 3 | TOL_VOLT_OPERAT_DC_MIN: -15 | Terminal connector, Input/Output: M12 connector, 8 pole | Safety Integrity Level (SIL), suitable for applications in: 3 | Number of semi-conductor outputs with signaling function: 1 | Active area: Glass-fibre, reinforced thermoplastic | Duration of risk, maximum: 30 | Voltage type: DC | PIN 5: Signalling output | Number of series-wiring of sensors: 16 | Repeat accuracy R: 0.2 | VOLT_TYPE_DIAGN_OUT: DC | Absicherung des Diagnoseausganges: short-circuit proof | PIN 2: X2 Safety input 2 | Absicherung des Sicherheitsausganges: short-circuit proof, p-type | Overvoltage category: 3 | Switch distance, typical: 8 | Reaction time, maximum: 30 | Performance Level, up to: e