Products Introduction

Schmersal MZM 100 ST2-1P2PR-A (Order No: 101210074) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +55 °C; Ambie...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal MZM 100 ST2-1P2PR-A, Order No: 101210074. Competitive pricing, fast quotation.

Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.

More Schmersal Products from Glorient

In addition to MZM 100 ST2-1P2PR-A, Glorient also supplies:

G50-050T02/02Y-FL1 Order No: 101122064
IFL 10-30L-10/01P Order No: 101127017
AZM40Z-I1-ST-1P2P Order No: 103034188
BNS 260-02/01Z-R 10,0M Order No: 101207906
PS215-Z12-H200 Order No: 103014971
SVE1/189-24VDC Order No: 101203730
AZ/AZM201-B30-RTAG1P1-SZ Order No: 103013499
G150-300T04Y-1637/1714 Order No: 101192673
SHGV/B01/130+BOF/HIS2 Order No: 101213434
BNS 250-11ZG 3,0M Order No: 101123995
T4V7H 335-11Z-RMS Order No: 151099072
G150-450Z11/11Y-1368-4-1600-1 Order No: 101170240
NDTBL/SW/504H Order No: 103009560
BDF200-NH-10-LT-LT-LT-G24-2875 Order No: 103007781
MS 6600-11-K-Y 1,5M -1326-5 Order No: 101103458
AV15LBKX30U-GB215 Order No: 103031357
AV15RBKX30-O.A.-GB215 Order No: 103042123
TYP.GEL. NAS 311 ST1- AS Order No: 101181767
MKTE52/206-2949-1 Order No: 103016114
PASSKERBSTIFT 1,5X6 S2 Order No: 101178860
T3C 236-11Z-M20 Order No: 151162012
SMS 4-850-1000-0214 Order No: 103012993
A4-RU-11-410-1W1 Order No: 101208592
IFL 15-30L-10TP-2130-2 6,0M Order No: 101179968
MKSA321 Order No: 101005816
AZM201Z-I2-CC-T-1P2PW-A Order No: 103017027
T1R 236-11Z-M16-U180 Order No: 151104654
TZG03/110 Order No: 101023564
SHGV/L01/124+BO Order No: 101197805
HEBELVORSATZ J KPL. AUSF. Y Order No: 101064817

Related Guides

Gross weight618 g
Net weight618 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661384146
Mission time20
TerminationConnector M12, 8-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor177.5 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | PIN 3: A2 GND | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | External wire and device fuse rating: 2 A gG (Connector M12, 8-pole) | Fuse rating to UL 508, maximum: 2 | Designation, Diagnostic outputs: OUT | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Rated operating voltage: 24 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Current consumption with magnet ON, average : 350 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | VOLT_TYPE_DIAGN_OUT: DC | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2