Schmersal MZM 100 B ST-1P2PW2REM-A (Order No: 101211069) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +55 °C; ...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal MZM 100 B ST-1P2PW2REM-A, Order No: 101211069. Competitive pricing, fast quotation.

Schmersal MZM 100 B ST-1P2PW2REM-A - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal MZM 100 B ST-1P2PW2REM-A is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight665 g
Net weight665 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661389110
Mission time20
TerminationConnector M23, 8+1-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor179 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Latching force, maximum: 115 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | Working principle: inductive | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M23, 8+1-pole | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Designation, Diagnostic outputs: OUT | External wire and device fuse rating: 2 A gG | Actuator monitored: Yes | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | Latching force, minimum: 45 | CADENAS: Yes | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PIN 9: without function | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Rated operating voltage: 24 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | FORCE_LATCH_GPV: 45 ... 115 N | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Current consumption with magnet ON, average : 350 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | VOLT_TYPE_DIAGN_OUT: DC | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2

More Schmersal Products from Glorient

In addition to MZM 100 B ST-1P2PW2REM-A, Glorient also supplies:

PS226-T11-J200 Order No: 103015094
EX-M. 441-11Y-1276-2 Order No: 103005964
TV7H 236-11Z-2138 Order No: 151122631
EX-Z1K 355-11Z-3G/D Order No: 151209912
BDF200-NHK-11-LTYE-LTWH-B Order No: 101213758
T4D 064-12Y Order No: 101060751
SLC440-ER-1290-30-H1 Order No: 103039668
SLC440COM-R-0650-35-1700 Order No: 103040556
Z4V7H 335-11Z-1637/2138 Order No: 151209161
PS116-Z12-ST-K250 Order No: 103006666
SMS 5-500-1700 Order No: 103035156
EDLWS/103 Order No: 101189733
SMS 4-936-1246-0273 Order No: 103033165
PS215-T12-S200 Order No: 103014979
CSS 8-180-2P-E-LST 3,5M Order No: 101181991
PS215-T12-K250 Order No: 103014994
EX-SHGV/L01/236+BOW-2GD Order No: 103026602
SLC440-ER-1290-14 Order No: 101216612
ESS21S12/EKM44 Order No: 101205691
RK-S-42-2ST8-2 Order No: 103013325
SLC440COM-R-1130-14 Order No: 103003936
G38910050 230 Order No: 103010209
SHGV/B01/251+BOW Order No: 103027383
T. 441-11Y-M20-243 Order No: 101170427
BN 65-10Z/V Order No: 101055824
DMNSW Order No: 101006881
M2S 660-11-K-Y 5,0M Order No: 101055376
AZ/AZM201-B30-RTAG1P20-SZ Order No: 103026321
BNS 16-12ZD-ST1 Order No: 101187135

Related Guides

Gross weight665 g
Net weight665 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661389110
Mission time20
TerminationConnector M23, 8+1-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor179 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Latching force, maximum: 115 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | Working principle: inductive | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M23, 8+1-pole | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Designation, Diagnostic outputs: OUT | External wire and device fuse rating: 2 A gG | Actuator monitored: Yes | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | Latching force, minimum: 45 | CADENAS: Yes | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PIN 9: without function | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Rated operating voltage: 24 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | FORCE_LATCH_GPV: 45 ... 115 N | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Current consumption with magnet ON, average : 350 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | VOLT_TYPE_DIAGN_OUT: DC | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2