Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

MZM 100 ST2-SD2PRE-A

Schmersal MZM 100 ST2-SD2PRE-A

Model: MZM 100 ST2-SD2PRE-A
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 19 views

Products Introduction

Schmersal MZM 100 ST2-SD2PRE-A (Order No: 101211145) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +55 °C; Ambi...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal MZM 100 ST2-SD2PRE-A, Order No: 101211145. Competitive pricing, fast quotation.

Schmersal MZM 100 ST2-SD2PRE-A - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal MZM 100 ST2-SD2PRE-A is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight620 g
Net weight620 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661389479
Mission time20
TerminationConnector M12, 8-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor177.5 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | FORCE_LATCH_GPV: 30 ... 100 N | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Serial diagnostics: Yes | External wire and device fuse rating: 2 A gG | Wiring capacitance: 50 | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Number of series-wiring of sensors: 31 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | CADENAS: Yes | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT serial diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole | TOL_VOLT_OPERAT_DC_MAX: 10 | Latching force, minimum: 30 | Latching force, maximum: 100 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Designation, Serial diagnostic SD: OUT | Current consumption with magnet ON, average : 350 | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Current, Utilisation category DC-13: 0.25 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | PIN 8: IN serial diagnostic input | Safety Integrity Level (SIL), suitable for applications in: 3 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2 | Operation current: 150

More Schmersal Products from Glorient

In addition to MZM 100 ST2-SD2PRE-A, Glorient also supplies:

PS216L-T11UEA3-K240-U2 Order No: 103030642
IFL 5-18L-10/01P Order No: 101139949
SCHALTELEMENT KPL.T Order No: 101087865
SHGV/LD1/207/32+BO Order No: 101198488
G150-150T11/11Y Order No: 101169702
SCHILD NHS-4GB Order No: 101184675
IFL 8-18M-10P Order No: 101113260
TS 016-03Y-M20 Order No: 131168064
M 630-11-2-A50-934 Order No: 101061432
SVE1/221-3Ö-24VDC Order No: 103040667
AZ 16-02ZVRK-M16-2254 Order No: 101156104
EDMBL Order No: 101006273
NDLWS/503D Order No: 101215601
SMS 4-830-1150 Order No: 103042773
EX-SHGV/B01/130+BO-2GD Order No: 103035762
T4VH 335-11Z-RMS-1637 Order No: 151134731
T3K 236-02Z-M20-U180 Order No: 151166173
TESZ1102/S/35 Order No: 101030520
SHGV/ESS21S2/30/103 Order No: 101205752
MS 6600-10-K-Y 0,8M -1326-5 Order No: 101115379
SVM1/155-6/255/E Order No: 103035524
BN 80-10Z 10,0M Order No: 101082680
SVE1/SR/109GN/GN-24VDC Order No: 103035200
RMEFWS Order No: 101188313
STW-C-10X25-4000-2 Order No: 103043712
SHGV/B01/40+BOF/HIS.2 Order No: 103014564
PS216-T12-ST-K230 Order No: 103041404
ESS21S1/EKM208 Order No: 103050366

Related Guides

Gross weight620 g
Net weight620 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661389479
Mission time20
TerminationConnector M12, 8-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor177.5 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | FORCE_LATCH_GPV: 30 ... 100 N | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Serial diagnostics: Yes | External wire and device fuse rating: 2 A gG | Wiring capacitance: 50 | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Number of series-wiring of sensors: 31 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | CADENAS: Yes | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT serial diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole | TOL_VOLT_OPERAT_DC_MAX: 10 | Latching force, minimum: 30 | Latching force, maximum: 100 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Designation, Serial diagnostic SD: OUT | Current consumption with magnet ON, average : 350 | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Current, Utilisation category DC-13: 0.25 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | PIN 8: IN serial diagnostic input | Safety Integrity Level (SIL), suitable for applications in: 3 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2 | Operation current: 150