AZM 161CC-12/03RI-024-B1

Schmersal AZM 161CC-12/03RI-024-B1

Model: AZM 161CC-12/03RI-024-B1
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 18 views

Products Introduction

Schmersal AZM 161CC-12/03RI-024-B1 (Order No: 101212388) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient temperatur...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM 161CC-12/03RI-024-B1, Order No: 101212388. Competitive pricing, fast quotation.

Schmersal AZM 161CC-12/03RI-024-B1 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM 161CC-12/03RI-024-B1 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight480 g
Net weight480 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078481 °C
Ambient temperature, minimum-25 °C
StandardsEN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1, BG-GS-ET-19
IP Degree of protectionIP67
CertificatesIFA, cULus, CCC
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661393728
Mission time20
TerminationCage clamps
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching elementNO contact, NC contact
Switching principleslow action, positive break NC contact
Width of sensor130 mm
Thermal test current6 A
Height of sensor90 mm
Material of the contacts, electricalSilver
Utilisation category DC-1324 VDC / 2.5 A
Max. fuse rating6 A gG D-fuse to DIN EN 60269-1
Utilisation category AC-15230 VAC / 4 A
Maximum switching frequency1,000 Hz
Number of safety contacts4 / 5
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteElectrical life on request.
Number of auxiliary contacts1 / 2
TracepartsYes
Storage and transport temperature-30 ... +85 °C
Scope of deliveryThe actuator is included in the scope of delivery
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-30 °C
MountingScrews
Note (General)minimum actuating radius on rotating guard systems via the narrow edge of the actuator 180 mm
Protection classII
Other ParametersVoltage, Utilisation category DC-13: 24 | Voltage, Utilisation category AC-15: 230 | Test pulse interval, minimum: 50 | Power to unlock: Yes | Number of actuating directions: 3 | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Performance Level, up to: e | Working principle: electromechanical | Positive break force, minimum: 30 | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | CADENAS: Yes | Latching force: 30 | Positive break travel: 10 | Current, Utilisation category DC-13: 4 | Material of the actuator: Stainless steel | Type of the fixing screws: 3x M6 | Allowed type of cable: solid single-wire | Coding: Individual coding | Current, Utilisation category AC-15: 4 | Electrical power consumption, maximum: 10 | Coding level according to EN ISO 14119: High | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Cable entry: 4 x M16 x 1,5 | Manual release: Yes | Note (Manual release): For maintenance, installation, etc. | Category: 3 | Actuating play in direction of actuation: 5.5 | Note (applications): removable guard | Tightening torque of the fastening screws for the housing cover: 0.6 | Positive break force per NC contact, minimum: 10 | Permissible installation altitude above sea level, maximum: 2,000 | Actuating radius, minimum: 150

More Schmersal Products from Glorient

In addition to AZM 161CC-12/03RI-024-B1, Glorient also supplies:

NZSO/1/V4A Order No: 101184036
TV15H 236-02Z-M16 Order No: 151208265
ACC-CGLD-AV-E2-M20-4 Order No: 103032141
BDF200-NH-20-LMRD-LMYE-LTGN Order No: 103003845
G50-017Z22/22Y-1601-4 Order No: 101122106
E-KB9WS/L00841171 Order No: 101218473
SLB440-ER-4-LST Order No: 103013528
BNS 260-11/01Z-ST-R Order No: 101184364
EDPRT Order No: 101006292
G50-017M44Y-1600-1 Order No: 101088393
EX-SHGV/L01/207+BO-2GD Order No: 103026609
G50-017Z11/22Y -1600-1 Order No: 101090355
T3K 236-11Z-M20-1565-2 Order No: 151173008
ZK4 236-11Z-M20-U90-1297 Order No: 151173488
BNS 303-11Z 8,0M Order No: 101132125
CSS 8-180-2P+D-E-LST Order No: 101169553
IFL 2-12-10P Order No: 101097496
E-KB9.1SW/L00841100 Order No: 101218130
SET SL 300-0320 Order No: 101136068
SMS 4-600-800-0242 Order No: 103016504
CSS-Y-A-8P-VA Order No: 103008718
AZ 17-11ZRK-ST-2493 Order No: 101188690
IFL 4-12M-01P 5,0M Order No: 101159502
EDT.VRT Order No: 101006145
NDLWS/519D Order No: 101189679
SHGV/D01/103+BOW Order No: 103008570
SLC445-ER-0810-30-01 Order No: 103005411

Related Guides

Gross weight480 g
Net weight480 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078481 °C
Ambient temperature, minimum-25 °C
StandardsEN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1, BG-GS-ET-19
IP Degree of protectionIP67
CertificatesIFA, cULus, CCC
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661393728
Mission time20
TerminationCage clamps
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching elementNO contact, NC contact
Switching principleslow action, positive break NC contact
Width of sensor130 mm
Thermal test current6 A
Height of sensor90 mm
Material of the contacts, electricalSilver
Utilisation category DC-1324 VDC / 2.5 A
Max. fuse rating6 A gG D-fuse to DIN EN 60269-1
Utilisation category AC-15230 VAC / 4 A
Maximum switching frequency1,000 Hz
Number of safety contacts4 / 5
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteElectrical life on request.
Number of auxiliary contacts1 / 2
TracepartsYes
Storage and transport temperature-30 ... +85 °C
Scope of deliveryThe actuator is included in the scope of delivery
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-30 °C
MountingScrews
Note (General)minimum actuating radius on rotating guard systems via the narrow edge of the actuator 180 mm
Protection classII
Other ParametersVoltage, Utilisation category DC-13: 24 | Voltage, Utilisation category AC-15: 230 | Test pulse interval, minimum: 50 | Power to unlock: Yes | Number of actuating directions: 3 | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Performance Level, up to: e | Working principle: electromechanical | Positive break force, minimum: 30 | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | CADENAS: Yes | Latching force: 30 | Positive break travel: 10 | Current, Utilisation category DC-13: 4 | Material of the actuator: Stainless steel | Type of the fixing screws: 3x M6 | Allowed type of cable: solid single-wire | Coding: Individual coding | Current, Utilisation category AC-15: 4 | Electrical power consumption, maximum: 10 | Coding level according to EN ISO 14119: High | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Cable entry: 4 x M16 x 1,5 | Manual release: Yes | Note (Manual release): For maintenance, installation, etc. | Category: 3 | Actuating play in direction of actuation: 5.5 | Note (applications): removable guard | Tightening torque of the fastening screws for the housing cover: 0.6 | Positive break force per NC contact, minimum: 10 | Permissible installation altitude above sea level, maximum: 2,000 | Actuating radius, minimum: 150