Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM 161SK-12/12RIA-024G-B1

Schmersal AZM 161SK-12/12RIA-024G-B1

Model: AZM 161SK-12/12RIA-024G-B1
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 22 views

Products Introduction

Schmersal AZM 161SK-12/12RIA-024G-B1 (Order No: 101214826) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient temperat...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM 161SK-12/12RIA-024G-B1, Order No: 101214826. Competitive pricing, fast quotation.

Schmersal AZM 161SK-12/12RIA-024G-B1 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM 161SK-12/12RIA-024G-B1 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight480 g
Net weight480 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078481 °C
Ambient temperature, minimum-25 °C
StandardsEN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1, BG-GS-ET-19
IP Degree of protectionIP67
CertificatesIFA, cULus, CCC
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661400020
Mission time20
TerminationScrew terminals
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching elementNO contact, NC contact
Switching principleslow action, positive break NC contact
Width of sensor130 mm
Thermal test current6 A
Cable section, maximum1.5 mm²
Height of sensor90 mm
Material of the contacts, electricalSilver
Utilisation category DC-1324 VDC / 2.5 A
Max. fuse rating6 A gG D-fuse to DIN EN 60269-1
Utilisation category AC-15230 VAC / 4 A
Maximum switching frequency1,000 Hz
Cable section, minimum0.25 mm²
Number of safety contacts4 / 5
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteAll indications including the conductor ferrules.
Number of auxiliary contacts1 / 2
TracepartsYes
Storage and transport temperature-30 ... +85 °C
Scope of deliverySlot sealing plugs
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-30 °C
MountingScrews
Note (General)minimum actuating radius on rotating guard systems via the narrow edge of the actuator 180 mm
Protection classII
Other ParametersVoltage, Utilisation category DC-13: 24 | Voltage, Utilisation category AC-15: 230 | Test pulse interval, minimum: 50 | Number of actuating directions: 3 | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Integral system diagnostics, status: Yes | Power to lock: Yes | Working principle: electromechanical | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | CADENAS: Yes | Latching force: 30 | Positive break travel: 10 | Current, Utilisation category DC-13: 4 | Material of the actuator: Stainless steel | Type of the fixing screws: 3x M6 | Positive break force, minimum: 20 | Allowed type of cable: solid single-wire | Coding: Individual coding | Current, Utilisation category AC-15: 4 | Electrical power consumption, maximum: 10 | Coding level according to EN ISO 14119: High | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Manual release: Yes | Tightening torque of electrical connection, maximum: 0.5 | Note (Manual release): For maintenance, installation, etc. | Category: 3 | Actuating play in direction of actuation: 5.5 | Note (applications): removable guard | Tightening torque of the fastening screws for the housing cover: 0.6 | Positive break force per NC contact, minimum: 10 | Permissible installation altitude above sea level, maximum: 2,000 | Tightening torque of electrical connection, minimum: 0.4 | Cable entry: 2 x M16 x 1.5 | Actuating radius, minimum: 150

More Schmersal Products from Glorient

In addition to AZM 161SK-12/12RIA-024G-B1, Glorient also supplies:

SHGV/RD1/212/32+BO Order No: 101210296
TV12H 235-11Z-M20 Order No: 151161597
SVM1/60-10/110/E Order No: 101213602
SHGV/LD1/175/33+BO Order No: 103047453
E-KB9.1SW/L00841309 Order No: 101218174
ZV7H 235-11ZZ-2483 Order No: 151179115
SHGV/B01/131+BO Order No: 101198120
RSS16-I1-D-ST8H Order No: 103009532
MZM 100 B ST2-1P2PW2RE-A Order No: 101211070
SRB402EM Order No: 101170840
NBG660 Order No: 103000728
ZV10H 235-11Z-M20 Order No: 151168162
PWR-20M Order No: 103003626
AZ/AZM201-B30-LTAG1G1-2649-1 Order No: 103032938
BNS 260-11ZG-R 3,0M Order No: 101213403
SLC440-ER-0970-30-01 Order No: 101216744
SHGV/D01/218+BOWR Order No: 103006354
SVE2/52/52-3Ö-24VDC Order No: 101197630
TD 250-01/01Z Order No: 101058138
MBK311/GB Order No: 101018717
SHGV-Z/B01/124+BOF/HIS2 Order No: 103044558
EX-BNS 250-11ZG-3GD 5M Order No: 103045600
WKTSA32 Order No: 101019551
SEKH58.110 Order No: 101020041
T. 441-11Y-1801 Order No: 101209137
ZK4 236-11Z-U90-1283 Order No: 151102888
M1R 660-11-K-Y 3,0M -1537 Order No: 101096067
SMS-5-500-1800 Order No: 103048682

Related Guides

Gross weight480 g
Net weight480 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078481 °C
Ambient temperature, minimum-25 °C
StandardsEN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1, BG-GS-ET-19
IP Degree of protectionIP67
CertificatesIFA, cULus, CCC
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661400020
Mission time20
TerminationScrew terminals
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching elementNO contact, NC contact
Switching principleslow action, positive break NC contact
Width of sensor130 mm
Thermal test current6 A
Cable section, maximum1.5 mm²
Height of sensor90 mm
Material of the contacts, electricalSilver
Utilisation category DC-1324 VDC / 2.5 A
Max. fuse rating6 A gG D-fuse to DIN EN 60269-1
Utilisation category AC-15230 VAC / 4 A
Maximum switching frequency1,000 Hz
Cable section, minimum0.25 mm²
Number of safety contacts4 / 5
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteAll indications including the conductor ferrules.
Number of auxiliary contacts1 / 2
TracepartsYes
Storage and transport temperature-30 ... +85 °C
Scope of deliverySlot sealing plugs
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-30 °C
MountingScrews
Note (General)minimum actuating radius on rotating guard systems via the narrow edge of the actuator 180 mm
Protection classII
Other ParametersVoltage, Utilisation category DC-13: 24 | Voltage, Utilisation category AC-15: 230 | Test pulse interval, minimum: 50 | Number of actuating directions: 3 | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Integral system diagnostics, status: Yes | Power to lock: Yes | Working principle: electromechanical | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | CADENAS: Yes | Latching force: 30 | Positive break travel: 10 | Current, Utilisation category DC-13: 4 | Material of the actuator: Stainless steel | Type of the fixing screws: 3x M6 | Positive break force, minimum: 20 | Allowed type of cable: solid single-wire | Coding: Individual coding | Current, Utilisation category AC-15: 4 | Electrical power consumption, maximum: 10 | Coding level according to EN ISO 14119: High | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Manual release: Yes | Tightening torque of electrical connection, maximum: 0.5 | Note (Manual release): For maintenance, installation, etc. | Category: 3 | Actuating play in direction of actuation: 5.5 | Note (applications): removable guard | Tightening torque of the fastening screws for the housing cover: 0.6 | Positive break force per NC contact, minimum: 10 | Permissible installation altitude above sea level, maximum: 2,000 | Tightening torque of electrical connection, minimum: 0.4 | Cable entry: 2 x M16 x 1.5 | Actuating radius, minimum: 150