Schmersal AZM 161 Z ST2-AS RT (Order No: 101215907) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient temperature: -2...
Glorient offers competitive supply of Schmersal AZM 161 Z ST2-AS RT, Order No: 101215907. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to AZM 161 Z ST2-AS RT, Glorient also supplies:
| Gross weight | 485 g |
| Net weight | 485 g |
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000078475 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 61508 |
| IP Degree of protection | IP67 |
| Certificates | cULus, ASi-SaW |
| Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661404691 |
| Mission time | 20 |
| Termination | Connector plug M12, 4-pole, (A-coding) |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 30 mm |
| Width of sensor | 130 mm |
| Height of sensor | 90 mm |
| Maximum switching frequency | 1,000 Hz |
| Actuating speed, maximum | 2 m/s |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Mounting | Screws |
| Degree of pollution | 3 |
| Protection class | II |
| Other Parameters | AS-i Outputs, DO 0: Solenoid control | Power to unlock: Yes | Number of actuating directions: 3 | Note (LED switching conditions display): (3) LED yellow: Channel 1 / AS-i SaW Bit 0.1 | AS-i Parameter bits, P0: Actuator detected | AS-i Outputs, DO 3: No Function | Note (Relative humidity): non-condensing | EPLAN: Yes | PFH value: 1.01 x 10⁻⁷ | Relative humidity: 30 ... 95 % | NOTE_VOLT_RATED_OPERAT_ASI: Protection against polarity reversal | Integral system diagnostics, status: Yes | AS-i Parameter bits, P2: Magnet voltage in tolerance range | Coding level according to EN ISO 14119: Low | AS-i Input module address: 0 | Note (AS-i Operating voltage): Protection against polarity reversal | AS-i, ID-Code1: 0xF | AS-i Profile : S-7.B.F.E | Performance Level, up to: e | Restistance to shock: 30 g / 11 ms | Note (AS-i Input module address): Preset to address 0, can be changed through AS-interface bus master or hand-held programming device | PIN 2: n.c. | AS-i Specification: Safety-Slave | Working principle: electromechanical | Note (AS-i Parameter bits): FID: periphery error | AS-i Operating voltage, minimum: 26.5 | AS-i Parameter bits, P3: Error message - locking/unlocking of the solenoid interlock blocked | Emergency exit: Yes | Protection class (Operating resource): 2 | Actuator monitored: Yes | PIN 4: n.c. | Safety Integrity Level (SIL), suitable for applications in: 1 | AS-i, ID-Code2: 0xE | Rated operating voltage: 26.5 ... 31.6 VDC (Protection against polarity reversal) | Latching force: 30 | VOLT_RATED_OPERAT_ASI_DC_MIN: 26.5 | AS-i Input, Channel 2: Data bits DI 2 / DI 3 = dynamic code transmission | Type of the fixing screws: 3x M6 | PIN 3: AS-Interface - | Connector position : Right | Reaction time, maximum: 100 | AS-i Version : V 2.1 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | AS-i Input, Channel 1: Data bits DI 0 / DI 1 = dynamic code transmission | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | AS-i Parameter bits, P1: Solenoid interlock locked | AS-i Current consumption, maximum: 250 | Note (Emergency exit): For cases of danger | Category: 3 | Actuating play in direction of actuation: 5.5 | Note (applications): removable guard | AS-i Device protection: Internal short-circuit proof | PIN 1: AS-i + | AS-i, ID-Code: 0xB | Solenoid interlock monitored: Yes | Note (PFH-value): up to max. 100,000 switching cycles/year | AS-i Outputs, DO 1: No Function | Permissible installation altitude above sea level, maximum: 2,000 | AS-i Outputs, DO 2: No Function | VOLT_TYPE_ASI: DC | AS-i, IO-Code: 0x7 | Overvoltage category: 3 | VOLT_RATED_OPERAT_ASI_DC_MAX: 31.6 | AS-i Operating voltage AS-i maximum: 31.6 |