Schmersal AZM300Z-I1-ST-1P2P (Order No: 103001437) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: +0 ... +60 °C; Ambien...
Glorient offers competitive supply of Schmersal AZM300Z-I1-ST-1P2P, Order No: 103001437. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to AZM300Z-I1-ST-1P2P, Glorient also supplies:
| Gross weight | 550 g |
| Net weight | 550 g |
| Ambient temperature | +0 ... +60 °C |
| Ambient temperature, maximum | +60 °C |
| Ambient temperature, minimum | +0 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP66 |
| Certificates | TÜV, cULus, ECOLAB, FCC, IC, UKCA, ANATEL |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 4030661425979 |
| Mission time | 20 |
| Termination | Connector M12, 8-pole, A-coded |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 120 mm |
| Width of sensor | 87.5 mm |
| Height of sensor | 35 mm |
| Utilisation category DC-13 | 24 VDC / 0.05 A |
| Required rated short-circuit current | 100 A |
| Traceparts | Yes |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
| Storage and transport temperature | -10 ... +90 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +90 °C |
| Storage and transport temperature, minimum | -10 °C |
| Note (General) | For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. |
| Degree of pollution | 3 |
| Protection class | III |
| Other Parameters | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Power to unlock: Yes | Number of actuating directions: 3 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | External wire and device fuse rating: 2 A gG | Category: 2 | Test pulse duration, maximum: 5 | Current consumption with magnet ON, peak: 350 mA / 200 ms | Safety Integrity Level (SIL), suitable for applications in: 2 | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Current consumption with magnet ON, average : 200 | Tightening torque of the fixing screws, maximum: 7 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | PFH value: 2.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Latching force, adjustable, position 2: 50 | Connection type: Connector M12, 8-pole, A-coded | ACE reference article number: 11930877 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | Operating current: 150 | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded | Latching force, adjustable, position 1: 25 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Latching force: 25 N / 50 N | Switching frequency, maximum: 0.5 | Type of the fixing screws: 2x M6 | Performance Level, up to: d | CADENAS: Yes | Note (Mechanical lifetime): When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Time to readiness, maximum: 5,000 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Coding: Individual coding | TOL_VOLT_OPERAT_DC_MAX: 10 | Recommendation (actuator): AZ/AZM300-B1 | Tightening torque of the fixing screws: 6 ... 7 Nm | Reaction time, switching off safety outputs via actuator, maximum: 100 | Switch distance, typical: 2 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Operating voltage: 20.4 ... 26.4 VDC | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | TOL_VOLT_OPERAT_DC_MIN: -15 | PFD value: 1.80 x 10⁻⁴ | Manual release: Yes | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Permissible installation altitude above sea level, maximum: 3,000 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | WEB_TECH_DATA_BA: Yes | Latching force (position 1 / position 2): 25 N / 50 N | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Tightening torque of the fixing screws, minimum: 6 | Electrical fuse rating, maximum: 2 | Designation, Safety outputs: Y1 and Y2 | Degree of protection: IP66, IP67, IP69 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Wiring capacitance: 50 |