Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM300Z-I2-ST-SD2P

Schmersal AZM300Z-I2-ST-SD2P

Model: AZM300Z-I2-ST-SD2P
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 17 views

Products Introduction

Schmersal AZM300Z-I2-ST-SD2P (Order No: 103001440) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: +0 ... +60 °C; Ambien...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM300Z-I2-ST-SD2P, Order No: 103001440. Competitive pricing, fast quotation.

Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.

More Schmersal Products from Glorient

In addition to AZM300Z-I2-ST-SD2P, Glorient also supplies:

UV10H 432Y Order No: 101060554
E-KB9WS/L00841191 Order No: 101218490
SVM1/SR/68-6/208RT/BR/E Order No: 101218953
RK-S-41-1ST8-1 Order No: 103013327
E-KB9.1SW/L00841071 Order No: 101218118
EF03F.3 Order No: 101006565
EDR35SW/KB504 Order No: 101192522
SMS 4-1090-1200 Order No: 103052405
BN 80-01Z 2,0M Order No: 101104039
T4VH 336-11Z-1525 Order No: 101082835
BN 120-RZ/V Order No: 101186844
T. 441-11Y-UE-1224 Order No: 101176116
M1S 660-11-K-Y 1,0M Order No: 101055429
ACC-IFL-MOCL-H40 Order No: 101068521
SMS 4-1000-1543-0280 Order No: 103033172
SVE3/119/119/119-3Ö-24VDC Order No: 103014183
BS-B30-150-RVA Order No: 153030653
ZV3H 015-11Y-M20-1629 Order No: 131170174
SHGV/B01/116+BOW Order No: 101198384
HEBEL 4D KPL. 335-1907 Order No: 101099682
WKTC32/1X401 Order No: 101019521
TK 422-10Y-T Order No: 101058878
FRONTEINSTELLBLOCK SPEZ 1600-1 Order No: 101096671
TZFW3OES24VDC-3053 Order No: 133038421
PS216-T20-ST-H200 Order No: 103049726
PWR-100M Order No: 103003627
ZDTSW/507D Order No: 101189494

Related Guides

Gross weight585 g
Net weight585 g
Ambient temperature+0 ... +60 °C
Ambient temperature, maximum+60 °C
Ambient temperature, minimum+0 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesTÜV, cULus, ECOLAB, FCC, IC, UKCA, ANATEL
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661426037
Mission time20
TerminationConnector M12, 8-pole, A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor120 mm
Width of sensor87.5 mm
Height of sensor35 mm
Utilisation category DC-1324 VDC / 0.05 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-10 ... +90 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+90 °C
Storage and transport temperature, minimum-10 °C
Note (General)For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.
Degree of pollution3
Protection classIII
Other ParametersCoding: Individual coding, multiple teaching | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Power to unlock: Yes | Number of actuating directions: 3 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | ACE reference article number: 193673 | External wire and device fuse rating: 2 A gG | Test pulse duration, maximum: 5 | Current consumption with magnet ON, peak: 350 mA / 200 ms | Safety Integrity Level (SIL), suitable for applications in: 2 | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Current consumption with magnet ON, average : 200 | Tightening torque of the fixing screws, maximum: 7 | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | PFH value: 2.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Category: 4 | Latching force, adjustable, position 2: 50 | Connection type: Connector M12, 8-pole, A-coded | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Serial diagnostics: Yes | Wiring capacitance: 50 | Operating current: 150 | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Latching force, adjustable, position 1: 25 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Latching force: 25 N / 50 N | Switching frequency, maximum: 0.5 | Type of the fixing screws: 2x M6 | Performance Level, up to: d | CADENAS: Yes | Note (Mechanical lifetime): When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT serial diagnostic output | Voltage, Utilisation category DC-12: 24 | Voltage, Utilisation category DC-13: 24 | Time to readiness, maximum: 5,000 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole, A-coded | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | Recommendation (actuator): AZ/AZM300-B1 | Tightening torque of the fixing screws: 6 ... 7 Nm | Reaction time, switching off safety outputs via actuator, maximum: 100 | Switch distance, typical: 2 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Operating voltage: 20.4 ... 26.4 VDC | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | TOL_VOLT_OPERAT_DC_MIN: -15 | PFD value: 1.80 x 10⁻⁴ | Designation, Serial diagnostic SD: OUT | Manual release: Yes | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Current, Utilisation category DC-13: 0.25 | Permissible installation altitude above sea level, maximum: 3,000 | PIN 1: A1 Supply voltage UB | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | WEB_TECH_DATA_BA: Yes | Current, Utilisation category DC-12: 0.25 | Latching force (position 1 / position 2): 25 N / 50 N | PIN 8: IN serial diagnostic input | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Tightening torque of the fixing screws, minimum: 6 | Electrical fuse rating, maximum: 2 | Designation, Safety outputs: Y1 and Y2 | Degree of protection: IP66, IP67, IP69 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Operation current: 150