Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com
Socomec Power Solutions: UPS, Modular Storage, DC Switchgear and Surge Protection Compared

Socomec Power Solutions: UPS, Modular Storage, DC Switchgear and Surge Protection Compared

Socomec Power Solutions: UPS, Modular Storage, DC Switchgear and Surge Protection Compared

At a Glance. Socomec's product lines solve distinct problems in industrial and renewable power systems: MASTERYS IP+ is the online double-conversion UPS for mission-critical AC loads; MAS BAT / MAS DIS BAT is the modular battery storage cabinet for energy buffering and peak shaving; SIRCO PV is the DC load-break switch for photovoltaic strings up to 1000 Vdc / 1500 Vdc; ATyS S is the automatic transfer switch for source-changeover between two AC supplies; and the FUS GG / CDE FE lines cover fused switch-disconnectors and distribution. This guide maps each product to its typical use case and gives a decision flow.

1. Side-by-Side Comparison Table

Product Family Primary Function Voltage Range Typical Use Stock Example
MASTERYS IP+Online double-conversion UPS3 / 3 phase, 400 VData centre, process control, medicalMASTERYS IP+ 30 kVA 3/3 400 WO
MAS BAT / MAS DIS BATModular battery cabinetDC 384–576 V (VRLA)UPS autonomy extension, peak shavingMAS DIS BAT-LL-2X44X92AH-4H-CB
SIRCO PVDC load-break switch (PV)Up to 1000 / 1500 VdcSolar string / array isolationSIRCO PV 4X600A F 1000Vdc
ATyS SAutomatic transfer switch400 VAC, 40–3200 AMain / generator source changeoverATyS S 4X80A F 230V
CT LBSLoad-break switch (AC)Up to 1600 A, 690 VLocal AC isolation, MCCCT LBS 4P 160A IP65 S2N
CDE FEFused switch-disconnectorUp to 1600 ADistribution with HRC fusesCDE FE 4 4X D-G
FUS GGCylindrical HRC fuse10x38 to 22x58, 500 VBranch-circuit short-circuit protectionFUS GG 10X38 20A
MAS BAT-LLLong-life battery shelf2 x 22 x 92 AhExtended autonomy, telecomMAS BAT-LL-2x22x92AH-2F-CB

2. Decision Guide — Which Socomec Product Fits Your Application?

  1. Critical AC load needs ride-through for power cuts / dips? → MASTERYS IP+ online UPS (30 kVA 3/3 for IT rooms, 10 kVA for smaller control cabinets).
  2. Need extended runtime beyond standard battery? → Add MAS BAT (MAS DIS BAT-LL) or MAS BAT-LL (2x22x92AH) long-life shelf.
  3. PV array, must isolate DC string under load? → SIRCO PV (4X600A 1000 Vdc) — DC-rated, breaks load safely.
  4. Two AC sources (utility + generator), automatic changeover? → ATyS S (4X80A 230V); size up to 1600 A with same family.
  5. Local AC isolation in a motor control centre? → CT LBS (4P 160A IP65) — visible-break, padlock-able.
  6. Short-circuit protection on a branch? → FUS GG cylindrical HRC fuse (10x38 20A), in combination with a fused switch-disconnector.
  7. Distribution panel needs fused switch? → CDE FE (4X D-G) with HRC fuse carriers.

3. UPS Sizing — One Line of Practical Guidance

Match UPS apparent power (kVA) to the sum of load kVA, then apply a 1.2–1.5 derating factor for inrush and future growth. A MASTERYS IP+ 30 kVA comfortably feeds a 20 kW IT rack plus an 8 kW control cabinet. For longer autonomy, add MAS BAT in the same footprint family; the SOCOMEC sizing tool gives exact cabinet combinations.

4. PV DC Switching — Why SIRCO PV and Not a Standard AC Switch

Standard AC switches are not rated for switching a DC arc, which is much harder to extinguish. The SIRCO PV series uses pole doubling (4 poles in series for 1000 Vdc) and arc-quenching chambers tested to IEC 60947-3, DC-21B / DC-PV2. Using an AC switch on a PV string risks contact welding and fire. Always check the DC-PV utilization category on the nameplate.

5. Quick FAQ

Q: Can MASTERYS IP+ run in parallel for redundancy?
Yes, up to 6 units in parallel with shared static-bypass and load-share bus (MASTERYS IP+ "XR" configuration).

Q: Are MAS batteries hot-swappable?
Yes, in modular configurations with individual breaker isolation. Refer to the MAS installation manual for exact steps.

Q: ATyS S 80 A — can it switch a generator in < 1 s?
Yes, the controller transitions in < 200 ms typical when both sources are healthy.

6. Related Products in Stock

Need a complete power continuity solution — UPS + batteries + changeover or DC switching? Request a quote with your load kVA, autonomy minutes, and source configuration; we will size and pre-assemble the full Socomec system.

Prev: Schmersal Safety Switches and Safety Light Curtains: RSS vs AZ vs SLC Selection Guide