Schmersal AZM161-B-ST1-AS-RAT (Order No: 103004962) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient temperature: -2...
Glorient offers competitive supply of Schmersal AZM161-B-ST1-AS-RAT, Order No: 103004962. Competitive pricing, fast quotation.
Schmersal AZM161-B-ST1-AS-RAT - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal AZM161-B-ST1-AS-RAT is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000078475 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 61508 |
| IP Degree of protection | IP67 |
| Certificates | cULus, ASi-SaW |
| Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661433561 |
| Mission time | 20 |
| Termination | Connector plug M12, 4-pole, (A-coding) |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 30 mm |
| Width of sensor | 130 mm |
| Height of sensor | 90 mm |
| Maximum switching frequency | 1,000 Hz |
| Actuating speed, maximum | 2 m/s |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Mounting | Screws |
| Degree of pollution | 3 |
| Protection class | II |
| Other Parameters | AS-i Outputs, DO 0: Solenoid control | Number of actuating directions: 3 | Note (LED switching conditions display): (3) LED yellow: Channel 1 / AS-i SaW Bit 0.1 | AS-i Parameter bits, P0: Actuator detected | AS-i Outputs, DO 3: No Function | Note (Relative humidity): non-condensing | EPLAN: Yes | PFH value: 1.01 x 10⁻⁷ | Relative humidity: 30 ... 95 % | NOTE_VOLT_RATED_OPERAT_ASI: Protection against polarity reversal | Integral system diagnostics, status: Yes | AS-i Parameter bits, P2: Magnet voltage in tolerance range | Coding level according to EN ISO 14119: Low | AS-i Input module address: 0 | Note (AS-i Operating voltage): Protection against polarity reversal | AS-i, ID-Code1: 0xF | AS-i Profile : S-7.B.F.E | Restistance to shock: 30 g / 11 ms | Note (AS-i Input module address): Preset to address 0, can be changed through AS-interface bus master or hand-held programming device | PIN 2: n.c. | Power to lock: Yes | AS-i Specification: Safety-Slave | Working principle: electromechanical | Note (AS-i Parameter bits): FID: periphery error | AS-i Operating voltage, minimum: 26.5 | AS-i Parameter bits, P3: Error message - locking/unlocking of the solenoid interlock blocked | Protection class (Operating resource): 2 | Actuator monitored: Yes | PIN 4: n.c. | Safety Integrity Level (SIL), suitable for applications in: 1 | AS-i, ID-Code2: 0xE | Latching force: 30 | VOLT_RATED_OPERAT_ASI_DC_MIN: 26.5 | AS-i Input, Channel 2: Data bits DI 2 / DI 3 = dynamic code transmission | Type of the fixing screws: 3x M6 | PIN 3: AS-Interface - | Connector position : Centre | Reaction time, maximum: 100 | AS-i Version : V 2.1 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | AS-i Input, Channel 1: Data bits DI 0 / DI 1 = dynamic code transmission | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | AS-i Parameter bits, P1: Solenoid interlock locked | AS-i Current consumption, maximum: 250 | Performance Level, up to: c | Note (Emergency exit): For cases of danger | Manual release: Yes | Category: 3 | Actuating play in direction of actuation: 5.5 | Note (applications): removable guard | AS-i Device protection: Internal short-circuit proof | Rated operating voltage: 26.5 ... 31.6 VDC (Protection against polarity reversal) | PIN 1: AS-i + | AS-i, ID-Code: 0xB | Note (PFH-value): up to max. 100,000 switching cycles/year | AS-i Outputs, DO 1: No Function | Permissible installation altitude above sea level, maximum: 2,000 | AS-i Outputs, DO 2: No Function | VOLT_TYPE_ASI: DC | AS-i, IO-Code: 0x7 | Overvoltage category: 3 | VOLT_RATED_OPERAT_ASI_DC_MAX: 31.6 | AS-i Operating voltage AS-i maximum: 31.6 |
In addition to AZM161-B-ST1-AS-RAT, Glorient also supplies:
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000078475 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 61508 |
| IP Degree of protection | IP67 |
| Certificates | cULus, ASi-SaW |
| Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| EAN (European Article Number) | 4030661433561 |
| Mission time | 20 |
| Termination | Connector plug M12, 4-pole, (A-coding) |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 30 mm |
| Width of sensor | 130 mm |
| Height of sensor | 90 mm |
| Maximum switching frequency | 1,000 Hz |
| Actuating speed, maximum | 2 m/s |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
| Storage and transport temperature | -25 ... +85 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -25 °C |
| Mounting | Screws |
| Degree of pollution | 3 |
| Protection class | II |
| Other Parameters | AS-i Outputs, DO 0: Solenoid control | Number of actuating directions: 3 | Note (LED switching conditions display): (3) LED yellow: Channel 1 / AS-i SaW Bit 0.1 | AS-i Parameter bits, P0: Actuator detected | AS-i Outputs, DO 3: No Function | Note (Relative humidity): non-condensing | EPLAN: Yes | PFH value: 1.01 x 10⁻⁷ | Relative humidity: 30 ... 95 % | NOTE_VOLT_RATED_OPERAT_ASI: Protection against polarity reversal | Integral system diagnostics, status: Yes | AS-i Parameter bits, P2: Magnet voltage in tolerance range | Coding level according to EN ISO 14119: Low | AS-i Input module address: 0 | Note (AS-i Operating voltage): Protection against polarity reversal | AS-i, ID-Code1: 0xF | AS-i Profile : S-7.B.F.E | Restistance to shock: 30 g / 11 ms | Note (AS-i Input module address): Preset to address 0, can be changed through AS-interface bus master or hand-held programming device | PIN 2: n.c. | Power to lock: Yes | AS-i Specification: Safety-Slave | Working principle: electromechanical | Note (AS-i Parameter bits): FID: periphery error | AS-i Operating voltage, minimum: 26.5 | AS-i Parameter bits, P3: Error message - locking/unlocking of the solenoid interlock blocked | Protection class (Operating resource): 2 | Actuator monitored: Yes | PIN 4: n.c. | Safety Integrity Level (SIL), suitable for applications in: 1 | AS-i, ID-Code2: 0xE | Latching force: 30 | VOLT_RATED_OPERAT_ASI_DC_MIN: 26.5 | AS-i Input, Channel 2: Data bits DI 2 / DI 3 = dynamic code transmission | Type of the fixing screws: 3x M6 | PIN 3: AS-Interface - | Connector position : Centre | Reaction time, maximum: 100 | AS-i Version : V 2.1 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | AS-i Input, Channel 1: Data bits DI 0 / DI 1 = dynamic code transmission | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | AS-i Parameter bits, P1: Solenoid interlock locked | AS-i Current consumption, maximum: 250 | Performance Level, up to: c | Note (Emergency exit): For cases of danger | Manual release: Yes | Category: 3 | Actuating play in direction of actuation: 5.5 | Note (applications): removable guard | AS-i Device protection: Internal short-circuit proof | Rated operating voltage: 26.5 ... 31.6 VDC (Protection against polarity reversal) | PIN 1: AS-i + | AS-i, ID-Code: 0xB | Note (PFH-value): up to max. 100,000 switching cycles/year | AS-i Outputs, DO 1: No Function | Permissible installation altitude above sea level, maximum: 2,000 | AS-i Outputs, DO 2: No Function | VOLT_TYPE_ASI: DC | AS-i, IO-Code: 0x7 | Overvoltage category: 3 | VOLT_RATED_OPERAT_ASI_DC_MAX: 31.6 | AS-i Operating voltage AS-i maximum: 31.6 |