Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

SLC240COM-ER-0890-35

Schmersal SLC240COM-ER-0890-35

Model: SLC240COM-ER-0890-35
Brand: Schmersal
Category: Safety Light Curtains
Views: 22 views

Products Introduction

Schmersal SLC240COM-ER-0890-35 (Order No: 103016257) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -10 ... +50 °C; Amb...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal SLC240COM-ER-0890-35, Order No: 103016257. Competitive pricing, fast quotation.

Schmersal SLC240COM-ER-0890-35 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal SLC240COM-ER-0890-35 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight1,540 g
Net weight1,540 g
Ambient temperature-10 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-10 °C
StandardsEN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661506845
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
Height of sensor931 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Category: 2 | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Radiation emission level to EN 12198-1: Category 0 | PIN 4: Slave Series wiring | Designation, Control inputs: Reset and Test | Integral system diagnostics, status: Yes | Switching voltage: 0 … 2 V (LOW) | PIN 5: Reset Restart interlock (manual reset) | Tolerance, percentage: 10 | PIN 2: Test Test input | Rated operating current, Emitter: 200 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | Switching thresholds: 24 V (HIGH) | TOL_VOLT_OPERAT_DC_MIN: -10 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | LED position: Receiver | Load inductance, maximum: 2 | Safety Integrity Level (SIL), suitable for applications in: 1 | CADENAS: Yes | Number of beams: 30 | Blanking function: Yes | Restart interlock (manual reset): Yes | Classification ZVEI CB24I, Sink: C1 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Cascadable: Yes | Safety type in accordance with IEC 61496-1: 2 | Terminal connector, Recipient: Connector plug M12, 5-pole | Performance Level, up to: c | Rated operating voltage: 24 | Voltage type: DC | Connection: Emitter | Test pulse interval, typical: 750 | Detection ability for test bodies at v = 1.6 m/s: 35 | PIN 3: 0 VDC power supply | ACE reference article number: 11930811 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Note (Software Version): as of 2017 Version 1.0 | Master- or Slave-function: Yes | Range, protection field, maximum: 7 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | LED status: OSSD ON, OSSD OFF, Restart interlock, Error, Parameter setting, Alignment kit, Indication of signal quality | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Height of the protection field: 890

More Schmersal Products from Glorient

In addition to SLC240COM-ER-0890-35, Glorient also supplies:

EMLGB/406 Order No: 103001242
EX-SHGV/L01/217+BOWR-2GD Order No: 103037048
ESS21S1/EKM193 Order No: 103050347
SHGV/B01/260+BOW Order No: 103039400
SMS 4-212-944-0130 Order No: 103003005
AZ 16-03ZIB1-M16-1747 Order No: 101150056
BDF200-NHK-11-LTBU-LTGN-LTYE Order No: 103001545
NMEBL Order No: 101163599
SD-I-U-MT Order No: 101218029
DDNRT/RT Order No: 101006750
T4V7H 335-03ZH-2138 Order No: 151215109
NDLWS/SYM-D1734 Order No: 101189991
SHGV/LD1/213/39+BO Order No: 101198533
SRB202MSL Order No: 101181998
ZV7H 236-11Z-M16-2138 Order No: 151169241
AZM 415-02/02ZPKA 24VAC/DC Order No: 101186204
G150-100T02/02Y-1601-2-FL1 Order No: 103007654
ASSB-4P-2M12-V1 Order No: 103001617
EX-Z4V10H 355-02Z-3G/D Order No: 101191220
SFB-EIP-8M12-IOP Order No: 103015480
T3K 335-11Z Order No: 101084116
SVE1/SR/155GR/WS-24VDC Order No: 103027113
TS 235-02Z Order No: 101091541
SHGV/L01/153+BO Order No: 101197834
T1R 236-11Z-2270 Order No: 101140208
BNS 303-11Z 5,0M Order No: 101123708

Related Guides

Gross weight1,540 g
Net weight1,540 g
Ambient temperature-10 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-10 °C
StandardsEN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661506845
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
Height of sensor931 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Category: 2 | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Radiation emission level to EN 12198-1: Category 0 | PIN 4: Slave Series wiring | Designation, Control inputs: Reset and Test | Integral system diagnostics, status: Yes | Switching voltage: 0 … 2 V (LOW) | PIN 5: Reset Restart interlock (manual reset) | Tolerance, percentage: 10 | PIN 2: Test Test input | Rated operating current, Emitter: 200 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | Switching thresholds: 24 V (HIGH) | TOL_VOLT_OPERAT_DC_MIN: -10 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | LED position: Receiver | Load inductance, maximum: 2 | Safety Integrity Level (SIL), suitable for applications in: 1 | CADENAS: Yes | Number of beams: 30 | Blanking function: Yes | Restart interlock (manual reset): Yes | Classification ZVEI CB24I, Sink: C1 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Cascadable: Yes | Safety type in accordance with IEC 61496-1: 2 | Terminal connector, Recipient: Connector plug M12, 5-pole | Performance Level, up to: c | Rated operating voltage: 24 | Voltage type: DC | Connection: Emitter | Test pulse interval, typical: 750 | Detection ability for test bodies at v = 1.6 m/s: 35 | PIN 3: 0 VDC power supply | ACE reference article number: 11930811 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Note (Software Version): as of 2017 Version 1.0 | Master- or Slave-function: Yes | Range, protection field, maximum: 7 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | LED status: OSSD ON, OSSD OFF, Restart interlock, Error, Parameter setting, Alignment kit, Indication of signal quality | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Height of the protection field: 890