Schmersal SFB-EIP-8M12-IOP

Model: SFB-EIP-8M12-IOP
Brand: Schmersal
Category: Bus IO Distribution Boxes
Views: 25 views

Products Introduction

Schmersal SFB-EIP-8M12-IOP (Order No: 103015480) is a genuine bus io distribution boxes engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient temperature: -...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal SFB-EIP-8M12-IOP, Order No: 103015480. Competitive pricing, fast quotation.

Schmersal SFB-EIP-8M12-IOP - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal SFB-EIP-8M12-IOP is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight649 g
Net weight649 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesUKCA
Housing materialThermoplastic, Polyamide PA 6 GF
EAN (European Article Number)4030661628691
Mission time20
TerminationM12 Connector socket/connector
Utilisation category DC-1324 VDC / 0.8 A / Inductive load, maximum 400 mH
TracepartsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
MountingScrews
Degree of pollution3
Protection classIII
Other ParametersOvervoltage category: III | Reaction Time Safety Output, maximum: 50 | LED status: Power-LED fieldbox | Designation, Safety inputs: X1 and X2 | Classification ZVEI CB24I, Sink: C1 | Category: 3 | Terminal connector, Input/Output: X0 - X7: M12, 8-pole, A-coded | Adressing: Dynamic Host Configuration Protocol (DHCP) / BootP | Designation, Diagnostic inputs / FB-Interface: DI | Performance Level, up to: e | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | Type of the fixing screws, viewing window: 2x TX10 (Torx) | EPLAN: Yes | Test pulse interval, maximum: 500 | Switching thresholds: −3 V … 5 V (Low) | Response time of local safety input ⇒ Fieldbus, maximum: 20 | Current, Utilisation category DC-12: 0.8 | Current consumption at 24 V: 6 | LED colour: green/red | Bezeichnung, Geräteanschlüsse: X0 ... X7 | Safety Integrity Level (SIL), suitable for applications in: 1 | Test pulse interval, typical: 500 | Designation, Power supply: A1 and A2 | Voltage, Utilisation category DC-12: 24 | Terminal Connector, Field bus: M12, 4-pole, D-coded | Restistance to shock: 30 g / 11 ms | Operating current: 10,000 | Tightening torque of electrical connection, minimum: 0.8 | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Classification ZVEI CB24I, Source: C1 | Time to readiness, maximum: 12,000 | Note (applications): Safe field box with decentralised I/Os | Feldbus Protokoll: EtherNet/IP / CIP Safety | Diagnostic Coverage (DC) Level: 99 | Note, Utilisation category DC-13: Inductive load, maximum 400 mH | Switching frequency, maximum: 1 | Test pulse interval, minimum: 15 | PFH value: 1.20 x 10⁻⁹ | Type of the fixing screws: 2x M6 | Tightening torque of electrical connection, maximum: 1.5 | Material of electronic encapsulation: Polyurethane 2K PU | CADENAS: Yes | Utilisation category DC-12: 24 VDC / 0.8 A | Fieldbus specification: V1.27 | Specification safety fieldbus: V2.22 | Tightening torque of electrical connection: 0.8 ... 1.5 Nm | LED position: L: P1 + P2 | Voltage, Utilisation category DC-13: 24 | Transfer rate: 100 Mbit/s Full Duplex | Designation, Test pulse outputs: Y1 and Y2 | Designation, Safety outputs: DO | Cable length, device port: 30 | Terminal Connector, Power I/O: M12 POWER, 4-pole, T-coded | TOL_VOLT_OPERAT_DC_MAX: 10 | Material of viewing window: Polyamide PACM 12 | Y2 rated current at 24 V: 10 | Tightening torque of the fixing screws, maximum: 3 | Test interval for error detection: 10 | Service interface: WEB-Interface HTTP | Note (Electrical data, Fuse rating): External fuse protection required ≤ 10A slow blow when used to UL 61010. | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Length: 222.8 | Current, Utilisation category DC-13: 0.8 | Test pulse duration, maximum: 1 | TOL_VOLT_OPERAT_DC_MIN: -15 | Data transfer rate FB-Interface: 19,2 kBaud | Internal electrical fuse: 1.5 A (Integrated automatic resettable fuse) | Relative humidity, minimum: 10 | Y2 rated current at 0 V: 30 | Rated operating voltage: 24 | Current consumption at 24V: 12 | Voltage type: DC | Width: 63 | Test pulse duration, minimum: 0.01 | Height: 36.1 | Integrated switch: Dual Port, 100 Mbit/s | Permissible installation altitude above sea level, maximum: 2,000 | Device Watchdog Time: 12 | Current consumption: 200 | Protection class (Operating resource): 3 | Fieldbus services: LLDP | Reaction Time Safety Input, maximum: 20 | Fieldbus properties: Device Level Ring (DLR) | Y1 rated current at 24 V: 15 | Integral system diagnostics, general: Yes | Rated operating current: 800 | Tightening torque of the fastening screws for the viewing window, maximum: 0.6 | Permissible residual drive current: 1 | Input debounce filter: 10 | Material of the marking plate: Plastic, Polyamide PA

More Schmersal Products from Glorient

In addition to SFB-EIP-8M12-IOP, Glorient also supplies:

AZ/AZM 200-B30-RTAG1P20-SZ Order No: 101216691
BN 32-11R Order No: 101057243
ZR 235-11Z-ST-RVA Order No: 151182866
SHGV/ESS21S2/105/103 Order No: 101205802
BNS 36-02/01Z-R Order No: 101193228
ACC-IFL-MOCL-H6.5 Order No: 101095263
IFL 10-30L-11TP-1766 Order No: 101127008
BP 31 Order No: 101057530
AZM150SK-02/02RI-230-B6R Order No: 153032224
RWT21 Order No: 101195518
EDT.VSW/502 Order No: 103008889
BNS 16-12ZLR-ST1 Order No: 101208885
T. 441-11Y-UE-966 Order No: 101056533
ACC-PWR-RC-5MM-NIRO Order No: 101203478
SMS 4-615-955 Order No: 103010448
SMS 4-200-1500 Order No: 103010599
AZM 415-11/11ZPKE 110VAC Order No: 101167191
EX-T4VH335-02Y Order No: 101212057
SLC440AS-E-1370-14 Order No: 103007528
KA-0981 Order No: 101213353
MKTB32/1x401/WKT-19.4 Order No: 101185302
T3K 336-11Z Order No: 101084111
TS 355-03Z Order No: 151148309
AZM 161SK-12/12RIA-024 -B6R Order No: 101211999
AZM 161CC-12/12RKA-024 - 2484 Order No: 101190060
SMS 5-840-1400 Order No: 103010035
Z4V7H 335-02Z-RMS-1172/2138 Order No: 153015295
SLG440COM-ER-0900-04 Order No: 103004064
AZM 161SK-12/03RKA-024 Order No: 101195892

Related Guides

Typical Applications

Schmersal safety switchgear is widely used in machine guarding and process safety applications, including CNC machining centres, robotic cell fencing, packaging and bottling lines, material handling equipment, press and forming machinery, and automated assembly stations. Choosing the correct interlock or position switch with the right contact rating and coding level is essential to meeting your machine's PL or SIL requirements.

Frequently Asked Questions

Is this Schmersal product 100% genuine?

Yes. All Schmersal products we supply are 100% genuine and new in original factory packing, sourced from authorised supply channels with full factory warranty.

Does this Schmersal model have positive-break safety contacts?

Schmersal safety switches use positive-break (Zwangsöffnung) contacts designed to EN 60947-5-1, which guarantee contact separation even if the actuator is forced out or the spring fails. This is the core requirement for safety circuits rated up to PL e according to EN ISO 13849-1.

How do I get a quotation and lead time?

Send us the part number through the quote form and our team will respond within 24 hours with pricing, stock availability and estimated delivery time.

Gross weight649 g
Net weight649 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesUKCA
Housing materialThermoplastic, Polyamide PA 6 GF
EAN (European Article Number)4030661628691
Mission time20
TerminationM12 Connector socket/connector
Utilisation category DC-1324 VDC / 0.8 A / Inductive load, maximum 400 mH
TracepartsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
MountingScrews
Degree of pollution3
Protection classIII
Other ParametersOvervoltage category: III | Reaction Time Safety Output, maximum: 50 | LED status: Power-LED fieldbox | Designation, Safety inputs: X1 and X2 | Classification ZVEI CB24I, Sink: C1 | Category: 3 | Terminal connector, Input/Output: X0 - X7: M12, 8-pole, A-coded | Adressing: Dynamic Host Configuration Protocol (DHCP) / BootP | Designation, Diagnostic inputs / FB-Interface: DI | Performance Level, up to: e | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | Type of the fixing screws, viewing window: 2x TX10 (Torx) | EPLAN: Yes | Test pulse interval, maximum: 500 | Switching thresholds: −3 V … 5 V (Low) | Response time of local safety input ⇒ Fieldbus, maximum: 20 | Current, Utilisation category DC-12: 0.8 | Current consumption at 24 V: 6 | LED colour: green/red | Bezeichnung, Geräteanschlüsse: X0 ... X7 | Safety Integrity Level (SIL), suitable for applications in: 1 | Test pulse interval, typical: 500 | Designation, Power supply: A1 and A2 | Voltage, Utilisation category DC-12: 24 | Terminal Connector, Field bus: M12, 4-pole, D-coded | Restistance to shock: 30 g / 11 ms | Operating current: 10,000 | Tightening torque of electrical connection, minimum: 0.8 | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Classification ZVEI CB24I, Source: C1 | Time to readiness, maximum: 12,000 | Note (applications): Safe field box with decentralised I/Os | Feldbus Protokoll: EtherNet/IP / CIP Safety | Diagnostic Coverage (DC) Level: 99 | Note, Utilisation category DC-13: Inductive load, maximum 400 mH | Switching frequency, maximum: 1 | Test pulse interval, minimum: 15 | PFH value: 1.20 x 10⁻⁹ | Type of the fixing screws: 2x M6 | Tightening torque of electrical connection, maximum: 1.5 | Material of electronic encapsulation: Polyurethane 2K PU | CADENAS: Yes | Utilisation category DC-12: 24 VDC / 0.8 A | Fieldbus specification: V1.27 | Specification safety fieldbus: V2.22 | Tightening torque of electrical connection: 0.8 ... 1.5 Nm | LED position: L: P1 + P2 | Voltage, Utilisation category DC-13: 24 | Transfer rate: 100 Mbit/s Full Duplex | Designation, Test pulse outputs: Y1 and Y2 | Designation, Safety outputs: DO | Cable length, device port: 30 | Terminal Connector, Power I/O: M12 POWER, 4-pole, T-coded | TOL_VOLT_OPERAT_DC_MAX: 10 | Material of viewing window: Polyamide PACM 12 | Y2 rated current at 24 V: 10 | Tightening torque of the fixing screws, maximum: 3 | Test interval for error detection: 10 | Service interface: WEB-Interface HTTP | Note (Electrical data, Fuse rating): External fuse protection required ≤ 10A slow blow when used to UL 61010. | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Length: 222.8 | Current, Utilisation category DC-13: 0.8 | Test pulse duration, maximum: 1 | TOL_VOLT_OPERAT_DC_MIN: -15 | Data transfer rate FB-Interface: 19,2 kBaud | Internal electrical fuse: 1.5 A (Integrated automatic resettable fuse) | Relative humidity, minimum: 10 | Y2 rated current at 0 V: 30 | Rated operating voltage: 24 | Current consumption at 24V: 12 | Voltage type: DC | Width: 63 | Test pulse duration, minimum: 0.01 | Height: 36.1 | Integrated switch: Dual Port, 100 Mbit/s | Permissible installation altitude above sea level, maximum: 2,000 | Device Watchdog Time: 12 | Current consumption: 200 | Protection class (Operating resource): 3 | Fieldbus services: LLDP | Reaction Time Safety Input, maximum: 20 | Fieldbus properties: Device Level Ring (DLR) | Y1 rated current at 24 V: 15 | Integral system diagnostics, general: Yes | Rated operating current: 800 | Tightening torque of the fastening screws for the viewing window, maximum: 0.6 | Permissible residual drive current: 1 | Input debounce filter: 10 | Material of the marking plate: Plastic, Polyamide PA