Schmersal IFL 10-30L-11TP-1766 (Order No: 101127008) is a genuine safety inductive sensors engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +70 °C; ...
Glorient offers competitive supply of Schmersal IFL 10-30L-11TP-1766, Order No: 101127008. Competitive pricing, fast quotation.
Schmersal IFL 10-30L-11TP-1766 - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal IFL 10-30L-11TP-1766 is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 180 g |
| Net weight | 180 g |
| Ambient temperature | -25 ... +70 °C |
| Ambient temperature, maximum | +110 °C |
| Ambient temperature, minimum | +0 °C |
| Standards | DIN VDE 0660-208, EN IEC 60947-5-2, DIN 19234 |
| IP Degree of protection | IP67 |
| Certificates | CCC |
| Housing material | Brass |
| EAN (European Article Number) | 4030661278162 |
| Termination | Cable |
| Length of sensor | 100 mm |
| Switching element | NO contact and NC contact (antivalent) |
| Housing construction form | Cylinder, thread |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Note (General) | Instead of nuts, a mounting clamp can be provided. |
| Protection class | II |
| Other Parameters | Rated operating voltage: 10 ... 60 VDC | Cable sleeve: Yes | Integral system diagnostics, status: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-2 | ISO thread of the sensor: M30 | Material of the Cable mantle: TPE-S | Restistance to shock: 30 g / 11 ms | Number of cable wires: 4 | Design of control elements: p-type | Protection class (Operating resource): 2 | Type of voltage range: DC | Wire cross-section: 0.25 | width across flats: 36 | Length of cable: 2 | Material of the nuts: Brass | Installation conditions (mechanical): flush | Operating voltage, minimum: 10 | Protection circuit integrated: inductive interference protection | VOLT_RATED_OPERAT_RANGE_DC_MIN: 10 | Tightening torque of nuts, maximum: 30 | Cable section: 1 mm² | Switching frequency, approx.: 200 | Operating voltage, maximum: 60 | VOLT_RATED_OPERAT_RANGE_DC_MAX: 60 | Operating voltage: 10 ... 60 VDC | Active area: Plastic | Housing coating material: nickel-plated | Operating current: 200 |
In addition to IFL 10-30L-11TP-1766, Glorient also supplies:
| Gross weight | 180 g |
| Net weight | 180 g |
| Ambient temperature | -25 ... +70 °C |
| Ambient temperature, maximum | +110 °C |
| Ambient temperature, minimum | +0 °C |
| Standards | DIN VDE 0660-208, EN IEC 60947-5-2, DIN 19234 |
| IP Degree of protection | IP67 |
| Certificates | CCC |
| Housing material | Brass |
| EAN (European Article Number) | 4030661278162 |
| Termination | Cable |
| Length of sensor | 100 mm |
| Switching element | NO contact and NC contact (antivalent) |
| Housing construction form | Cylinder, thread |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Note (General) | Instead of nuts, a mounting clamp can be provided. |
| Protection class | II |
| Other Parameters | Rated operating voltage: 10 ... 60 VDC | Cable sleeve: Yes | Integral system diagnostics, status: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-2 | ISO thread of the sensor: M30 | Material of the Cable mantle: TPE-S | Restistance to shock: 30 g / 11 ms | Number of cable wires: 4 | Design of control elements: p-type | Protection class (Operating resource): 2 | Type of voltage range: DC | Wire cross-section: 0.25 | width across flats: 36 | Length of cable: 2 | Material of the nuts: Brass | Installation conditions (mechanical): flush | Operating voltage, minimum: 10 | Protection circuit integrated: inductive interference protection | VOLT_RATED_OPERAT_RANGE_DC_MIN: 10 | Tightening torque of nuts, maximum: 30 | Cable section: 1 mm² | Switching frequency, approx.: 200 | Operating voltage, maximum: 60 | VOLT_RATED_OPERAT_RANGE_DC_MAX: 60 | Operating voltage: 10 ... 60 VDC | Active area: Plastic | Housing coating material: nickel-plated | Operating current: 200 |