Schmersal SFB-PN-IRT-8M12-IOP-V2 (Order No: 103040357) is a genuine bus io distribution boxes engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient temperat...
Glorient offers competitive supply of Schmersal SFB-PN-IRT-8M12-IOP-V2, Order No: 103040357. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to SFB-PN-IRT-8M12-IOP-V2, Glorient also supplies:
| Gross weight | 655 g |
| Net weight | 655 g |
| Ambient temperature | -25 ... +55 °C |
| Ambient temperature, maximum | +55 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP66 |
| Certificates | TÜV, cULus, UKCA |
| Housing material | Thermoplastic, Polyamide PA 6 GF |
| EAN (European Article Number) | 4030661561554 |
| Mission time | 20 |
| Termination | M12 Connector socket/connector |
| Utilisation category DC-13 | 24 VDC / 0.8 A / Inductive load, maximum 400 mH |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm / 5 g |
| Storage and transport temperature | -25 ... +70 °C |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Mounting | Screws |
| Degree of pollution | 3 |
| Protection class | III |
| Other Parameters | Overvoltage category: III | Reaction Time Safety Output, maximum: 50 | LED status: Power-LED fieldbox | Designation, Safety inputs: X1 and X2 | Rated operating voltage: 24 VDC - 15 % / + 10 % (stabilised PELV) | Classification ZVEI CB24I, Sink: C1 | Category: 3 | Feldbus Protokoll: PROFINET / PROFIsafe | Integrated switch: Dual Port, 100 Mbit/s, IRT fähig | Terminal connector, Input/Output: X0 - X7: M12, 8-pole, A-coded | Designation, Diagnostic inputs / FB-Interface: DI | Performance Level, up to: e | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | Type of the fixing screws, viewing window: 2x TX10 (Torx) | EPLAN: Yes | Test pulse interval, maximum: 500 | Switching thresholds: −3 V … 5 V (Low) | Response time of local safety input ⇒ Fieldbus, maximum: 20 | Fieldbus properties: Media Redundancy Protocol (MRP) | Current, Utilisation category DC-12: 0.8 | Current consumption at 24 V: 6 | LED colour: green/red | Bezeichnung, Geräteanschlüsse: X0 ... X7 | Safety Integrity Level (SIL), suitable for applications in: 1 | Test pulse interval, typical: 500 | Designation, Power supply: A1 and A2 | Voltage, Utilisation category DC-12: 24 | Terminal Connector, Field bus: M12, 4-pole, D-coded | Restistance to shock: 30 g / 11 ms | Operating current: 10,000 | Tightening torque of electrical connection, minimum: 0.8 | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Classification ZVEI CB24I, Source: C1 | Fieldbus specification: V2.3, Conformance Class C | Specification safety fieldbus: V2.4 | Note (applications): Safe field box with decentralised I/Os | Diagnostic Coverage (DC) Level: 99 | Note, Utilisation category DC-13: Inductive load, maximum 400 mH | Switching frequency, maximum: 1 | Test pulse interval, minimum: 15 | PFH value: 1.20 x 10⁻⁹ | Type of the fixing screws: 2x M6 | Tightening torque of electrical connection, maximum: 1.5 | Material of electronic encapsulation: Polyurethane 2K PU | CADENAS: Yes | Utilisation category DC-12: 24 VDC / 0.8 A | Tightening torque of electrical connection: 0.8 ... 1.5 Nm | LED position: L: P1 + P2 | Voltage, Utilisation category DC-13: 24 | Transfer rate: 100 Mbit/s Full Duplex | Designation, Test pulse outputs: Y1 and Y2 | Designation, Safety outputs: DO | Cable length, device port: 30 | Device Acknowledgement Time, maximum: 25 | Fieldbus network load class: 3 | Terminal Connector, Power I/O: M12 POWER, 4-pole, T-coded | TOL_VOLT_OPERAT_DC_MAX: 10 | Material of viewing window: Polyamide PACM 12 | Y2 rated current at 24 V: 10 | Tightening torque of the fixing screws, maximum: 3 | Test interval for error detection: 10 | Service interface: WEB-Interface HTTP | Note (Electrical data, Fuse rating): External fuse protection required ≤ 10A slow blow when used to UL 61010. | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Length: 222.8 | Current, Utilisation category DC-13: 0.8 | Test pulse duration, maximum: 1 | TOL_VOLT_OPERAT_DC_MIN: -15 | Notes (Safety Integrity Level): This product must only be replaced in the application by an identical product of type SFB-PN-IRT-8M12-IOP-V2 with part no. 103040357. The older product version has a lower safety level. | Data transfer rate FB-Interface: 19,2 kBaud | Internal electrical fuse: 1.5 A (Integrated automatic resettable fuse) | Relative humidity, minimum: 10 | Y2 rated current at 0 V: 30 | Current consumption at 24V: 12 | Voltage type: DC | Width: 63 | Test pulse duration, minimum: 0.01 | Height: 36.1 | Device Watchdog Time: 10 | Permissible installation altitude above sea level, maximum: 2,000 | Adressing: Discovery and Configuration Protocol (DCP) | Current consumption: 200 | Protection class (Operating resource): 3 | Reaction Time Safety Input, maximum: 20 | ACE reference article number: 11930890 | Y1 rated current at 24 V: 15 | Integral system diagnostics, general: Yes | Rated operating current: 800 | Tightening torque of the fastening screws for the viewing window, maximum: 0.6 | Permissible residual drive current: 1 | Input debounce filter: 10 | Material of the marking plate: Plastic, Polyamide PA | Time to readiness, maximum: 8,000 |