Schmersal SLG440-ER-0900-04-H1 (Order No: 103009191) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25_+50 °C; Ambient...
Glorient offers competitive supply of Schmersal SLG440-ER-0900-04-H1, Order No: 103009191. Competitive pricing, fast quotation.
Schmersal SLG440-ER-0900-04-H1 - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal SLG440-ER-0900-04-H1 is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 1,629 g |
| Net weight | 1,629 g |
| Ambient temperature | -25_+50 °C |
| Ambient temperature, maximum | 1000079351 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 61496-1 |
| IP Degree of protection | IP66 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661458618 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Number of beams: 4 | Reaction time, maximum: 10 | Bluetooth transmission frequency: 2.400 … 2.483 | Number of fail-safe digital outputs: 2 | Current consumption: 0 … 2 mA (LOW) | PIN 4: COD2 Coding 2 | PIN 5: Restart 2 Acknowledgement restart interlock 2 | Beam coding available : Yes | Bluetooth transmission power, maximum: 2 | Radiation emission level to EN 12198-1: Category 0 | EPLAN: Yes | Range, protection field, maximum: 20 | Integral system diagnostics, status: Yes | Actuation time for manual start: 50 … 1500 | PIN 2: 24 VDC power supply | Terminal connector, Recipient: Connector plug M12, 8-pole | Switching voltage: 0 … 2 V (LOW) | Tolerance, percentage: 10 | Height of Receiver: 1,020 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | TOL_VOLT_OPERAT_DC_MIN: -10 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Note (Software Version): as of 2021 Version 3.1 | Load inductance, maximum: 2 | Note (applications): automatic mode, restart interlock, double reset, contactor control, beam blanking fixed and floating, beam coding A | CADENAS: Yes | PIN 6: DOUT Operating Mode | Blanking function: Yes | Restart interlock (manual reset): Yes | Detection ability for test bodies at v = 1.6 m/s: 300 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Range, protection field, minimum: 4 | Classification ZVEI CB24I, Source: C3 | Length of cable: 100 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: Release/restart interlock Acknowledgement restart interlock | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | PIN 3: OSSD 1 Safety output 1 | Designation, Safety outputs: OSSD 1 and OSSD 2 | Safety Integrity Level (SIL), suitable for applications in: 3 | Height of transmitter: 1,010 | Designation, Contactor controls EDM (Feedback circuits): Contactor control | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Rated operating voltage: 24 | LED status: transmitting and status | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Bluetooth: Yes | PIN 8: Contactor control Input EDM | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Designation, Control inputs: Release/restart and Restart 2 | Protection class (Operating resource): 3 | Reaction time of the external devices, maximum: 500 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | PIN 7: 0 VDC power supply | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Height of the protection field: 900 | ACE reference article number: 11937059 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |
In addition to SLG440-ER-0900-04-H1, Glorient also supplies:
| Gross weight | 1,629 g |
| Net weight | 1,629 g |
| Ambient temperature | -25_+50 °C |
| Ambient temperature, maximum | 1000079351 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 61496-1 |
| IP Degree of protection | IP66 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661458618 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Number of beams: 4 | Reaction time, maximum: 10 | Bluetooth transmission frequency: 2.400 … 2.483 | Number of fail-safe digital outputs: 2 | Current consumption: 0 … 2 mA (LOW) | PIN 4: COD2 Coding 2 | PIN 5: Restart 2 Acknowledgement restart interlock 2 | Beam coding available : Yes | Bluetooth transmission power, maximum: 2 | Radiation emission level to EN 12198-1: Category 0 | EPLAN: Yes | Range, protection field, maximum: 20 | Integral system diagnostics, status: Yes | Actuation time for manual start: 50 … 1500 | PIN 2: 24 VDC power supply | Terminal connector, Recipient: Connector plug M12, 8-pole | Switching voltage: 0 … 2 V (LOW) | Tolerance, percentage: 10 | Height of Receiver: 1,020 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | TOL_VOLT_OPERAT_DC_MIN: -10 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Note (Software Version): as of 2021 Version 3.1 | Load inductance, maximum: 2 | Note (applications): automatic mode, restart interlock, double reset, contactor control, beam blanking fixed and floating, beam coding A | CADENAS: Yes | PIN 6: DOUT Operating Mode | Blanking function: Yes | Restart interlock (manual reset): Yes | Detection ability for test bodies at v = 1.6 m/s: 300 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Range, protection field, minimum: 4 | Classification ZVEI CB24I, Source: C3 | Length of cable: 100 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: Release/restart interlock Acknowledgement restart interlock | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | PIN 3: OSSD 1 Safety output 1 | Designation, Safety outputs: OSSD 1 and OSSD 2 | Safety Integrity Level (SIL), suitable for applications in: 3 | Height of transmitter: 1,010 | Designation, Contactor controls EDM (Feedback circuits): Contactor control | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Rated operating voltage: 24 | LED status: transmitting and status | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Bluetooth: Yes | PIN 8: Contactor control Input EDM | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Designation, Control inputs: Release/restart and Restart 2 | Protection class (Operating resource): 3 | Reaction time of the external devices, maximum: 500 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | PIN 7: 0 VDC power supply | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Height of the protection field: 900 | ACE reference article number: 11937059 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |