Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

RSS16-I2-SD-CC

Schmersal RSS16-I2-SD-CC

Model: RSS16-I2-SD-CC
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 16 views

Products Introduction

Schmersal RSS16-I2-SD-CC (Order No: 103009530) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: 2 x M5, Cylinder head screw; Ambient ...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal RSS16-I2-SD-CC, Order No: 103009530. Competitive pricing, fast quotation.

Schmersal RSS16-I2-SD-CC - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal RSS16-I2-SD-CC is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight160 g
Net weight160 g
Ambient temperature-28 ... +70 °C
Ambient temperature, maximum+70 °C
Ambient temperature, minimum-30 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatesTÜV, cULus, FCC, IC, ANATEL
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661462202
Mission time20
TerminationSpring pulley connection
Length of sensor91 mm
Width of sensor52 mm
Cable section, maximum1.5 mm²
Height of sensor30 mm
Utilisation category DC-1324 VDC / 1 A
Cable section, minimum0.25 mm²
Required rated short-circuit current100 A
Housing construction formBlock
Safety functionsYes
Storage and transport temperature-28 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-28 °C
Mounting2 x M5, Cylinder head screw
Degree of pollution3
Other ParametersCoding: Individual coding, multiple teaching | Number of fail-safe digital outputs: 2 | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Actuating panels: from head | Operating current: 2,100 | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Operating current, minimum: 0.5 | Hysteresis (Switching distance), maximum: 2 | Cable section: 0.25 mm² ... 1.5 mm² | Note (LED switching conditions display): LED green: Supply voltage | Series-wiring: Yes | Output current, (fail-safe output), maximum: 1 | Cross-circuit detection: Yes | Current, Utilisation category DC-13: 1 | Switching frequency, maximum: 1 | Voltage, Utilisation category DC-12: 24 | Design of control elements: short-circuit proof, p-type | Restistance to shock: 30 g / 11 ms | Utilisation category DC-12: 24_1 | Relative humidity, maximum: 93 | PFD value: 1.50 x 10⁻⁵ | Serial diagnostics: Yes | Wiring capacitance: 50 | Number of series-wiring of sensors: 31 | Operating voltage: 24 VDC -15 % / +10 % | Working principle: RFID | Rated operating voltage, minimum: 20.4 VDC | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Rated operating voltage, maximum: 26.4 VDC | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Active area: front side | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | Installation conditions (mechanical): not flush | Reaction time, maximum: 100 | Category: 4 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Tightening torque of the fixing screws: 2 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | Number of LEDs: 2 | Duration of risk, maximum: 200 | Coding level according to EN ISO 14119: High | Cascadable: Yes | Cable entry: 4 x M16 x 1,5 | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Designation, Serial diagnostic SD: OUT | Current consumption of the safety inputs: 5 | Number of semi-conductor outputs with signaling function: 1 | Time to readiness, maximum: 2,000 | Rated operating current (safety outputs): 1,000 | Rated operating voltage: 24 | Voltage type: DC | Interfering radiation: IEC 61000-6-4 | Recommendation (actuator): RST16-1 | Permissible installation altitude above sea level, maximum: 2,000 | Switch distance, typical: 15 | Absicherung des Sicherheitsausganges: short-circuit proof, p-type | Overvoltage category: 3 | Recommended safety switchgear: PROTECT PSC1 | Operation current: 150 | Performance Level, up to: e | PFH value: 6.30 x 10⁻¹¹

More Schmersal Products from Glorient

In addition to RSS16-I2-SD-CC, Glorient also supplies:

PS316-Z11-H300 Order No: 103015139
PS215-T12-ST-S200 Order No: 103032461
SLC440-ER-0410-14 Order No: 101216600
AZM150SK-02/02RIA-024-B5 Order No: 153044391
BP 20 S Order No: 101057541
ZV7H 235-11Z-M20 Order No: 151168066
SSG-SB-L-1000-200-175-SWGB-L20 Order No: 103042833
BOLZEN -2406-11 Order No: 101193638
ACC-IFL-MOCL-H20 Order No: 101097871
BN 20-11Z-M16 Order No: 101168014
SVM1/163-10/263/E Order No: 103040301
T1K 335-11Z-RMS Order No: 101217654
ZS 236-11Z-1467-3 Order No: 151108809
SEPLC05.2.2.1.22/95.Z1.Z7 Order No: 101210581
PS315-T03-H300 Order No: 103027037
T. 422-10Y-T Order No: 101056479
T 6881-11-1-80R-1637 Order No: 103038644
E-KB9.1SW/L00841285 Order No: 101218150
BDF-U200-PBC-DT-BU Order No: 103015998
IFL 5-18-01A Order No: 101141569
M 697-11-1-8R-I -1411-2 Order No: 101055187
TK 236-02ZH-M20 Order No: 151172062
Z4V7H 336-11Z-M20-1058/2138 Order No: 151165339
AZ 17-02ZRK-2243 5,0M Order No: 101139551
G50-017M44Y-1300-3 Order No: 101094866
BNS 303-11ZG 3,0M Order No: 101139171
BN 20-RE SCHALTROHRWANNE Order No: 101057098
TQ 900-13 Order No: 101184481

Related Guides

Gross weight160 g
Net weight160 g
Ambient temperature-28 ... +70 °C
Ambient temperature, maximum+70 °C
Ambient temperature, minimum-30 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatesTÜV, cULus, FCC, IC, ANATEL
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661462202
Mission time20
TerminationSpring pulley connection
Length of sensor91 mm
Width of sensor52 mm
Cable section, maximum1.5 mm²
Height of sensor30 mm
Utilisation category DC-1324 VDC / 1 A
Cable section, minimum0.25 mm²
Required rated short-circuit current100 A
Housing construction formBlock
Safety functionsYes
Storage and transport temperature-28 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-28 °C
Mounting2 x M5, Cylinder head screw
Degree of pollution3
Other ParametersCoding: Individual coding, multiple teaching | Number of fail-safe digital outputs: 2 | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Actuating panels: from head | Operating current: 2,100 | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Operating current, minimum: 0.5 | Hysteresis (Switching distance), maximum: 2 | Cable section: 0.25 mm² ... 1.5 mm² | Note (LED switching conditions display): LED green: Supply voltage | Series-wiring: Yes | Output current, (fail-safe output), maximum: 1 | Cross-circuit detection: Yes | Current, Utilisation category DC-13: 1 | Switching frequency, maximum: 1 | Voltage, Utilisation category DC-12: 24 | Design of control elements: short-circuit proof, p-type | Restistance to shock: 30 g / 11 ms | Utilisation category DC-12: 24_1 | Relative humidity, maximum: 93 | PFD value: 1.50 x 10⁻⁵ | Serial diagnostics: Yes | Wiring capacitance: 50 | Number of series-wiring of sensors: 31 | Operating voltage: 24 VDC -15 % / +10 % | Working principle: RFID | Rated operating voltage, minimum: 20.4 VDC | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Rated operating voltage, maximum: 26.4 VDC | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Active area: front side | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | Installation conditions (mechanical): not flush | Reaction time, maximum: 100 | Category: 4 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Tightening torque of the fixing screws: 2 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | Number of LEDs: 2 | Duration of risk, maximum: 200 | Coding level according to EN ISO 14119: High | Cascadable: Yes | Cable entry: 4 x M16 x 1,5 | TOL_VOLT_OPERAT_DC_MIN: -15 | Safety Integrity Level (SIL), suitable for applications in: 3 | Designation, Serial diagnostic SD: OUT | Current consumption of the safety inputs: 5 | Number of semi-conductor outputs with signaling function: 1 | Time to readiness, maximum: 2,000 | Rated operating current (safety outputs): 1,000 | Rated operating voltage: 24 | Voltage type: DC | Interfering radiation: IEC 61000-6-4 | Recommendation (actuator): RST16-1 | Permissible installation altitude above sea level, maximum: 2,000 | Switch distance, typical: 15 | Absicherung des Sicherheitsausganges: short-circuit proof, p-type | Overvoltage category: 3 | Recommended safety switchgear: PROTECT PSC1 | Operation current: 150 | Performance Level, up to: e | PFH value: 6.30 x 10⁻¹¹