Schmersal EX-BNS 180-12Z-2187-2-3G/D 10,0M (Order No: 101208353) is a genuine explosion-proof switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ...
Glorient offers competitive supply of Schmersal EX-BNS 180-12Z-2187-2-3G/D 10,0M, Order No: 101208353. Competitive pricing, fast quotation.
Schmersal EX-BNS 180-12Z-2187-2-3G/D 10,0M - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal EX-BNS 180-12Z-2187-2-3G/D 10,0M is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 401 g |
| Net weight | 401 g |
| Ambient temperature | -25 ... +70 °C |
| Ambient temperature, maximum | +70 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP67 |
| Certificates | ATEX (Konformitätserklärung) |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 4030661379913 |
| Mission time | 20 |
| Termination | cable |
| Length of sensor | 36 mm |
| Switching element | 1 NO contact, 2 NC contacts |
| Number of safety contacts | 2 |
| Actuating element | Magnet |
| Housing construction form | Cylinder, thread |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Note (General) | The safety sensor must be mounted in such a way that actuation with another magnet is impossible (concealed mounting according to EN ISO 14119) |
| Other Parameters | Material of the Cable mantle: PVC | Number of cable wires: 6 | Switching frequency, maximum: 5 | Short circuit detection: Yes | Recommendation (actuator): BP 10 | Cross-circuit detection: Yes | Switching capacity, maximum: 5 | Recommended safety switchgear: SRB-E-301ST | Restistance to shock: 30 g / 11 ms | Switching distance actuator: Actuating magnet BP 8, Sar: 20 mm | Impact energy, maximum: 2 | Number of normally open (NO): 1 | Explosion protection category: 3G | Installation conditions (mechanical): quasi-flush | Wire cross-section: 0.25 | Explosion protection: regulations: EN IEC 60079-0 | ISO thread of the sensor: M18 | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Active area: front side | Traceparts, product ID: 33-22052019-077538 | Direction of motion: Head-on to the active surface | Number of normally closed (NC): 2 | Switching voltage, maximum: 120 | Switching current, maximum: 0.25 | Length of cable: 10 | Manufacturer declaration: ATEX Zone 2 and 22 | Coding: Yes | Explosion protection zones: 22 |
In addition to EX-BNS 180-12Z-2187-2-3G/D 10,0M, Glorient also supplies:
| Gross weight | 401 g |
| Net weight | 401 g |
| Ambient temperature | -25 ... +70 °C |
| Ambient temperature, maximum | +70 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP67 |
| Certificates | ATEX (Konformitätserklärung) |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 4030661379913 |
| Mission time | 20 |
| Termination | cable |
| Length of sensor | 36 mm |
| Switching element | 1 NO contact, 2 NC contacts |
| Number of safety contacts | 2 |
| Actuating element | Magnet |
| Housing construction form | Cylinder, thread |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Actuator must be ordered separately. |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Note (General) | The safety sensor must be mounted in such a way that actuation with another magnet is impossible (concealed mounting according to EN ISO 14119) |
| Other Parameters | Material of the Cable mantle: PVC | Number of cable wires: 6 | Switching frequency, maximum: 5 | Short circuit detection: Yes | Recommendation (actuator): BP 10 | Cross-circuit detection: Yes | Switching capacity, maximum: 5 | Recommended safety switchgear: SRB-E-301ST | Restistance to shock: 30 g / 11 ms | Switching distance actuator: Actuating magnet BP 8, Sar: 20 mm | Impact energy, maximum: 2 | Number of normally open (NO): 1 | Explosion protection category: 3G | Installation conditions (mechanical): quasi-flush | Wire cross-section: 0.25 | Explosion protection: regulations: EN IEC 60079-0 | ISO thread of the sensor: M18 | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Active area: front side | Traceparts, product ID: 33-22052019-077538 | Direction of motion: Head-on to the active surface | Number of normally closed (NC): 2 | Switching voltage, maximum: 120 | Switching current, maximum: 0.25 | Length of cable: 10 | Manufacturer declaration: ATEX Zone 2 and 22 | Coding: Yes | Explosion protection zones: 22 |