Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM201B-SK-T-1P2PW-A

Schmersal AZM201B-SK-T-1P2PW-A

Model: AZM201B-SK-T-1P2PW-A
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 15 views

Products Introduction

Schmersal AZM201B-SK-T-1P2PW-A (Order No: 103013911) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +60 °C; Amb...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM201B-SK-T-1P2PW-A, Order No: 103013911. Competitive pricing, fast quotation.

Schmersal AZM201B-SK-T-1P2PW-A - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM201B-SK-T-1P2PW-A is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight588 g
Net weight588 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078519 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesUKCA
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661493398
Mission time20
TerminationScrew terminals
Mechanical lifetime, minimum1,000,000
Length of sensor50 mm
Width of sensor40 mm
Cable section, maximum1.5 mm²
Height of sensor220 mm
Utilisation category DC-1324 VDC / 0.25 A
Cable section, minimum0.25 mm²
Required rated short-circuit current100 A
Actuating speed, maximum0.2 m/s
NoteTorx T10
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersOperating current: 1,200 | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Wiring capacitance: 50 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Tightening torque of the fastening screws for the housing cover: 0.7 ... 1 Nm (Torx T10) | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Test pulse duration, maximum: 5 | Allowed type of cable: solid single-wire, solid multi-wire, flexible | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Wire cross-section, minimum: 23 | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): AZ/AZM201-B1 | Current consumption with magnet ON, average : 200 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | PFH value: 1.00 x 10⁻⁸ | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | External wire and device fuse rating: 4A when used in accordance with UL 508 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | PFD value: 8.90 x 10⁻⁴ | Actuator monitored: Yes | Coding: Universal coding | Performance Level, up to: d | Classification ZVEI CB24I, Sink: C1 | Fuse rating to UL 508, maximum: 4 | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Tightening torque of the fixing screws, maximum: 8 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | Latching force: 30 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Wire cross-section, maximum: 15 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Connection type: Screw terminals, Connector M12, 8-pole, Spring pulley connection | TOL_VOLT_OPERAT_DC_MAX: 10 | Wire cross-section: 23_15 | Current consumption with magnet ON, peak: 700 mA / 100 ms | Reaction time, switching off safety outputs via actuator, maximum: 100 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Frequency band RFID: 125 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Manual release: Yes | Rated operating voltage: 24 | ACE reference article number: 11930840 | Voltage type: DC | Safety Integrity Level (SIL), suitable for applications in: 2 | Length of sensor chain, maximum: 200 | Number of digital fail-safe inputs : 2 | Permissible installation altitude above sea level, maximum: 2,000 | Cable entry: 1 x M20 | REVIEW_ELEC_WIRING_GENERAL_GPV: Screw terminals | Degree of protection: IP66, IP67 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Tightening torque of the fastening screws for the housing cover, minimum: 0.7 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5

More Schmersal Products from Glorient

In addition to AZM201B-SK-T-1P2PW-A, Glorient also supplies:

TESZ/S/30 Order No: 101030511
DICHTUNG SEPLC-1 Order No: 101024456
AZM150SK-02/02R-110 Order No: 153032121
E-KB9WS/L00841193 Order No: 101218492
SVE2/202/202-3Ö-24VDC Order No: 103035558
AZ 16-12ZVK-M20-1762 Order No: 101209526
BODENDECKEL VA AZ/AZM 415 SPEZ Order No: 101168508
DTNRT/SWELOX. Order No: 101194689
SHGV/B01/132+BOW Order No: 101198400
T5C 236-02Z-ST Order No: 151196348
SLC440AS-ER-0810-14 Order No: 103007480
TR 335-11Z-M20-1879 Order No: 151171887
T4V7H 336-20Z-2138 Order No: 151147863
AZM 170-02ZRI-B1-2197 24VAC/DC Order No: 101144275
SVM1/41-10/191/E Order No: 103027179
PS226-Z12-K210 Order No: 103015057
RDTWS/508 Order No: 101197139
AV15RB2KX45U-GB215 Order No: 103025411
PS116-Z12-ST-R200 Order No: 103006663
ML 441-11Y-T-1276-2 Order No: 101095970
AZM201B-I2-CC-T-1P2PW Order No: 103013488
SLC440COM-E-1450-30 Order No: 103003974
BDF200-LTRD-11-LTGN-LMRD-LTGN Order No: 103005884
SLC445-ER-0410-30-01 Order No: 103005406
E-KB9WS/L00841122 Order No: 101218434
AZ 17-02ZI B6L Order No: 101122858
SMS-5-500-1800 Order No: 103048682
T4V7H 335-11Z-M20 Order No: 151168108
PS215-Z02-H200 Order No: 103027026

Related Guides

Gross weight588 g
Net weight588 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078519 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatesUKCA
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661493398
Mission time20
TerminationScrew terminals
Mechanical lifetime, minimum1,000,000
Length of sensor50 mm
Width of sensor40 mm
Cable section, maximum1.5 mm²
Height of sensor220 mm
Utilisation category DC-1324 VDC / 0.25 A
Cable section, minimum0.25 mm²
Required rated short-circuit current100 A
Actuating speed, maximum0.2 m/s
NoteTorx T10
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersOperating current: 1,200 | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Wiring capacitance: 50 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Tightening torque of the fastening screws for the housing cover: 0.7 ... 1 Nm (Torx T10) | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Test pulse duration, maximum: 5 | Allowed type of cable: solid single-wire, solid multi-wire, flexible | Design of control elements: short-circuit proof, p-type | Note (Relative humidity): non-condensing | EPLAN: Yes | Wire cross-section, minimum: 23 | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): AZ/AZM201-B1 | Current consumption with magnet ON, average : 200 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | PFH value: 1.00 x 10⁻⁸ | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | External wire and device fuse rating: 4A when used in accordance with UL 508 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | PFD value: 8.90 x 10⁻⁴ | Actuator monitored: Yes | Coding: Universal coding | Performance Level, up to: d | Classification ZVEI CB24I, Sink: C1 | Fuse rating to UL 508, maximum: 4 | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Tightening torque of the fixing screws, maximum: 8 | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | Latching force: 30 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Wire cross-section, maximum: 15 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Connection type: Screw terminals, Connector M12, 8-pole, Spring pulley connection | TOL_VOLT_OPERAT_DC_MAX: 10 | Wire cross-section: 23_15 | Current consumption with magnet ON, peak: 700 mA / 100 ms | Reaction time, switching off safety outputs via actuator, maximum: 100 | Designation, Magnet control: IN | Duration of risk, maximum: 200 | Frequency band RFID: 125 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Manual release: Yes | Rated operating voltage: 24 | ACE reference article number: 11930840 | Voltage type: DC | Safety Integrity Level (SIL), suitable for applications in: 2 | Length of sensor chain, maximum: 200 | Number of digital fail-safe inputs : 2 | Permissible installation altitude above sea level, maximum: 2,000 | Cable entry: 1 x M20 | REVIEW_ELEC_WIRING_GENERAL_GPV: Screw terminals | Degree of protection: IP66, IP67 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Tightening torque of the fastening screws for the housing cover, minimum: 0.7 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5