Schmersal SLC445-ER-0410-30-01 (Order No: 103005406) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +50 °C; Amb...
Glorient offers competitive supply of Schmersal SLC445-ER-0410-30-01, Order No: 103005406. Competitive pricing, fast quotation.
Schmersal SLC445-ER-0410-30-01 - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal SLC445-ER-0410-30-01 is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 980 g |
| Net weight | 980 g |
| Ambient temperature | -25 ... +50 °C |
| Ambient temperature, maximum | +50 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | CLC/TS 61496-2, EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661436203 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Reaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Rated operating current: 250 | Current consumption: 0 … 2 mA (LOW) | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | PIN 11: Not used | PIN 4: COD2 Coding 2 | Beam coding available : Yes | Number of beams: 20 | Radiation emission level to EN 12198-1: Category 0 | Designation, Contactor controls EDM (Feedback circuits): D_IN | EPLAN: Yes | Integral system diagnostics, status: Yes | PIN 5: D_OUT Operating Mode | Actuation time for manual start: 50 … 1500 | Switching voltage: 0 … 2 V (LOW) | PIN 2: 0 VDC power supply | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | Height of the protection field: 410 | Override: Yes | TOL_VOLT_OPERAT_DC_MIN: -10 | Terminal connector, Recipient: Connector plug M12, 12-pole | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Designation, Control inputs: S1, S2, MSG 1 and MSG 2 | CADENAS: Yes | Blanking function: Yes | PIN 8: Input Release S2 | Restart interlock (manual reset): Yes | Designation, Power supply: ML | Range, protection field, maximum: 10 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Classification ZVEI CB24I, Source: C3 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Contactor control integrated: Yes | Designation, Safety outputs: OSSD 1 and OSSD 2 | Clock control possible : Yes | PIN 6: OSSD 2 Safety output 2 | ACE reference article number: 11930063 | Safety Integrity Level (SIL), suitable for applications in: 3 | LED status: OSSD ON, OSSD OFF, restart, signal reception, blanking, information | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Rated operating voltage: 24 | Height of the Sensor (Transmitter): 491 | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Muting function: Yes | PIN 3: 0 VDC power supply | Height of the Sensor (Receiver): 501 | Note (Software Version): as of 2024 Version 1.0 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Reduced resolution : Yes | Reaction time of the external devices, maximum: 500 | Detection ability for test bodies at v = 1.6 m/s: 30 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |
In addition to SLC445-ER-0410-30-01, Glorient also supplies:
| Gross weight | 980 g |
| Net weight | 980 g |
| Ambient temperature | -25 ... +50 °C |
| Ambient temperature, maximum | +50 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | CLC/TS 61496-2, EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661436203 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Reaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Rated operating current: 250 | Current consumption: 0 … 2 mA (LOW) | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | PIN 11: Not used | PIN 4: COD2 Coding 2 | Beam coding available : Yes | Number of beams: 20 | Radiation emission level to EN 12198-1: Category 0 | Designation, Contactor controls EDM (Feedback circuits): D_IN | EPLAN: Yes | Integral system diagnostics, status: Yes | PIN 5: D_OUT Operating Mode | Actuation time for manual start: 50 … 1500 | Switching voltage: 0 … 2 V (LOW) | PIN 2: 0 VDC power supply | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | Height of the protection field: 410 | Override: Yes | TOL_VOLT_OPERAT_DC_MIN: -10 | Terminal connector, Recipient: Connector plug M12, 12-pole | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Designation, Control inputs: S1, S2, MSG 1 and MSG 2 | CADENAS: Yes | Blanking function: Yes | PIN 8: Input Release S2 | Restart interlock (manual reset): Yes | Designation, Power supply: ML | Range, protection field, maximum: 10 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Classification ZVEI CB24I, Source: C3 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Contactor control integrated: Yes | Designation, Safety outputs: OSSD 1 and OSSD 2 | Clock control possible : Yes | PIN 6: OSSD 2 Safety output 2 | ACE reference article number: 11930063 | Safety Integrity Level (SIL), suitable for applications in: 3 | LED status: OSSD ON, OSSD OFF, restart, signal reception, blanking, information | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Rated operating voltage: 24 | Height of the Sensor (Transmitter): 491 | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Muting function: Yes | PIN 3: 0 VDC power supply | Height of the Sensor (Receiver): 501 | Note (Software Version): as of 2024 Version 1.0 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Reduced resolution : Yes | Reaction time of the external devices, maximum: 500 | Detection ability for test bodies at v = 1.6 m/s: 30 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |