Schmersal SLC440COM-ER-1130-14-1700 (Order No: 103040459) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -10 ... +50 °C...
Glorient offers competitive supply of Schmersal SLC440COM-ER-1130-14-1700, Order No: 103040459. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to SLC440COM-ER-1130-14-1700, Glorient also supplies:
Schmersal safety switchgear is widely used in machine guarding and process safety applications, including CNC machining centres, robotic cell fencing, packaging and bottling lines, material handling equipment, press and forming machinery, and automated assembly stations. Choosing the correct interlock or position switch with the right contact rating and coding level is essential to meeting your machine's PL or SIL requirements.
Yes. All Schmersal products we supply are 100% genuine and new in original factory packing, sourced from authorised supply channels with full factory warranty.
Schmersal safety switches use positive-break (Zwangsöffnung) contacts designed to EN 60947-5-1, which guarantee contact separation even if the actuator is forced out or the spring fails. This is the core requirement for safety circuits rated up to PL e according to EN ISO 13849-1.
Send us the part number through the quote form and our team will respond within 24 hours with pricing, stock availability and estimated delivery time.
| Brand | Schmersal |
| Order No | 103040459 |
| Ambient temperature | -10 ... +50 °C |
| Ambient temperature, maximum | +50 °C |
| Ambient temperature, minimum | -10 °C |
| Standards | EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |