AZM400Z-ST2-2P2P-BOW-E

Schmersal AZM400Z-ST2-2P2P-BOW-E

Model: AZM400Z-ST2-2P2P-BOW-E
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 16 views

Products Introduction

Schmersal AZM400Z-ST2-2P2P-BOW-E (Order No: 103015312) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -20 ... +55 °C; A...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM400Z-ST2-2P2P-BOW-E, Order No: 103015312. Competitive pricing, fast quotation.

Schmersal AZM400Z-ST2-2P2P-BOW-E - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM400Z-ST2-2P2P-BOW-E is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight860 g
Net weight860 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatescULus
Housing materialLight alloy die-casting
EAN (European Article Number)4030661503998
Mission time20
Termination2 connector M12, 8 and 5 pin., both A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor46.7 mm
Width of sensor77.8 mm
Height of sensor156.7 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
NoteProtection class remains with correctly installed bowden cable release
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-40 ... +85 °C
Scope of deliveryThe actuator and the Bowden cable are not included in delivery.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Degree of pollution3
Protection classIII
Other ParametersPIN 3: A2 GND | Number of fail-safe digital outputs: 2 | Current consumption at 24V, maximum: 10 | Switching thresholds of the control inputs: 15 V … 30 V (High) | External wire and device fuse rating: 2 A gG (2 connector M12, 8 and 5 pin., both A-coded) | Note (LED switching conditions display): Error / functional defect: LED red | PFH value: 1.00 x 10⁻⁹ | Time to readiness, maximum: 1,500 | Connection: Connector 2 | Design of control elements: short-circuit proof, p-type | Interlocking principle: bistable | Electronic manual release: Yes | Note (Relative humidity): non-condensing | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Lateral force at bolt return, maximal (against locked door): 300 | Minimal average cycle time (with continuous operation): 20 | PFD value: 9.00 x 10⁻⁵ | Coding level according to EN ISO 14119: Low | Note (Mechanical lifetime): Which have a lateral force Ftrans = 100 N: 100.000 operations | Allowed distance interlock to actuator, minimum: 1 | Cross-circuit detection: Yes | PIN 6: E3 Control input 3 | Rated operating voltage: 24 VDC | Voltage, Utilisation category DC-12: 24 | Category: 4 | Auxiliary power supply Uhe: 24 VDC -15 % / +10 % (UPS / uninterruptable power supply) | Classification ZVEI CB24I, Source: C1 | Performance Level, up to: e | Restistance to shock: 30 g / 11 ms | PIN 1: A1 Supply voltage UB | PIN 2: H2 GND | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 8: E2 Control input 2 | Relative humidity, maximum: 93 | Note (Type of the fixing screws): Property class min. 10.9 | Safety Integrity Level (SIL), suitable for applications in: 3 | Coding: Universal coding | Minimum distance devices: 30 | PIN 4: H1 Auxiliary voltage Uhe | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | CADENAS: Yes | Utilisation category DC-12: 24 VDC / 0.25 A | Operating current while bolt movement, peak: 600 mA / 100 ms | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Permissible residual drive current: 1.5 | Classification ZVEI CB24I, Sink: C1 | Test pulse duration, maximum: 5 | Recommendation (actuator): AZM400-B1 | Designation, Control inputs: E1 und E2 (p-schaltend), E3 (n-schaltend) | TOL_VOLT_OPERAT_DC_MAX: 10 | REVIEW_ELEC_WIRING_GENERAL_GPV: 2 connector M12, 8 and 5 pin., both A-coded | Allowable discrepancy time (input), maximum: 10 | Allowed distance interlock to actuator, maximum: 7 | Reaction time, switching off safety outputs via actuator, maximum: 100 | Traceparts, product ID: 69-26052015-108616 | Designation, Diagnostic outputs: OUT1 / OUT2 | Tightening torque of the fixing screws Bowden cable: 1.2 | Frequency band RFID: 125 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Note (Lateral force at bolt return): Does not apply to emergency exit, Bowden cable and manual release | Switching frequency, maximum: 0.3 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Number of diagnostic signals: 2 | PIN 5: OUT1 Diagnostic output 1 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Current consumption at 24V, minimum: 5 | Test pulse interval, typical: 1,000 | Electrical fuse rating, maximum: 2 | Securing holes for Bowden cable assembly: Yes | Open / close cycle (motor), minimum: 3 | Tightening torque of the screw: 8 | Designation, Safety outputs: Y1 and Y2 | Test pulse interval, maximum: 40

More Schmersal Products from Glorient

In addition to AZM400Z-ST2-2P2P-BOW-E, Glorient also supplies:

SLC440AS-ER-0250-14 Order No: 103007438
REL. 12V SFS-3 12V PAN Order No: 101210316
SHGV/LD1/122/72+BO Order No: 101215702
NDTP30BL Order No: 103005364
NMEWS Order No: 101161885
ZK 235-11Z-M20 Order No: 151164307
SHGV/LD1/211/44+BOW Order No: 101213480
SLC445-ER-0490-30-01 Order No: 103005407
G150-450T44/44Y-1600-1 Order No: 101154746
M4VH 355-20Z-M20 Order No: 101162003
TA 471-02/02Y-H-1770 Order No: 101096457
BDF200-NH-11-LTGN-LTGN-LTRD Order No: 103001291
RMEHGN Order No: 101195071
SH-440-ER-03 Order No: 103026834
T4V7H 336-20Z-M20 Order No: 151171499
SHGV/LD1/218/39+BO Order No: 101198554
SMS 4-150-340 Order No: 103026218
EDP35GN Order No: 101006346
EDT.VRT/504 Order No: 101187542
IFL 2-8-01STP Order No: 101117680
PS316-T03-K370 Order No: 103031819
ENA11.110 Order No: 101023653
SVM1/100-10/102/A Order No: 103051232
WKTE52 Order No: 101019461
T3K 235-20Z Order No: 151091555
A-K3P-M8-R-G-2,5M-GY-1-X-X-4 Order No: 103011095

Related Guides

Gross weight860 g
Net weight860 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatescULus
Housing materialLight alloy die-casting
EAN (European Article Number)4030661503998
Mission time20
Termination2 connector M12, 8 and 5 pin., both A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor46.7 mm
Width of sensor77.8 mm
Height of sensor156.7 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
NoteProtection class remains with correctly installed bowden cable release
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-40 ... +85 °C
Scope of deliveryThe actuator and the Bowden cable are not included in delivery.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Degree of pollution3
Protection classIII
Other ParametersPIN 3: A2 GND | Number of fail-safe digital outputs: 2 | Current consumption at 24V, maximum: 10 | Switching thresholds of the control inputs: 15 V … 30 V (High) | External wire and device fuse rating: 2 A gG (2 connector M12, 8 and 5 pin., both A-coded) | Note (LED switching conditions display): Error / functional defect: LED red | PFH value: 1.00 x 10⁻⁹ | Time to readiness, maximum: 1,500 | Connection: Connector 2 | Design of control elements: short-circuit proof, p-type | Interlocking principle: bistable | Electronic manual release: Yes | Note (Relative humidity): non-condensing | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Lateral force at bolt return, maximal (against locked door): 300 | Minimal average cycle time (with continuous operation): 20 | PFD value: 9.00 x 10⁻⁵ | Coding level according to EN ISO 14119: Low | Note (Mechanical lifetime): Which have a lateral force Ftrans = 100 N: 100.000 operations | Allowed distance interlock to actuator, minimum: 1 | Cross-circuit detection: Yes | PIN 6: E3 Control input 3 | Rated operating voltage: 24 VDC | Voltage, Utilisation category DC-12: 24 | Category: 4 | Auxiliary power supply Uhe: 24 VDC -15 % / +10 % (UPS / uninterruptable power supply) | Classification ZVEI CB24I, Source: C1 | Performance Level, up to: e | Restistance to shock: 30 g / 11 ms | PIN 1: A1 Supply voltage UB | PIN 2: H2 GND | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 8: E2 Control input 2 | Relative humidity, maximum: 93 | Note (Type of the fixing screws): Property class min. 10.9 | Safety Integrity Level (SIL), suitable for applications in: 3 | Coding: Universal coding | Minimum distance devices: 30 | PIN 4: H1 Auxiliary voltage Uhe | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | CADENAS: Yes | Utilisation category DC-12: 24 VDC / 0.25 A | Operating current while bolt movement, peak: 600 mA / 100 ms | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Permissible residual drive current: 1.5 | Classification ZVEI CB24I, Sink: C1 | Test pulse duration, maximum: 5 | Recommendation (actuator): AZM400-B1 | Designation, Control inputs: E1 und E2 (p-schaltend), E3 (n-schaltend) | TOL_VOLT_OPERAT_DC_MAX: 10 | REVIEW_ELEC_WIRING_GENERAL_GPV: 2 connector M12, 8 and 5 pin., both A-coded | Allowable discrepancy time (input), maximum: 10 | Allowed distance interlock to actuator, maximum: 7 | Reaction time, switching off safety outputs via actuator, maximum: 100 | Traceparts, product ID: 69-26052015-108616 | Designation, Diagnostic outputs: OUT1 / OUT2 | Tightening torque of the fixing screws Bowden cable: 1.2 | Frequency band RFID: 125 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Note (Lateral force at bolt return): Does not apply to emergency exit, Bowden cable and manual release | Switching frequency, maximum: 0.3 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Number of diagnostic signals: 2 | PIN 5: OUT1 Diagnostic output 1 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Current consumption at 24V, minimum: 5 | Test pulse interval, typical: 1,000 | Electrical fuse rating, maximum: 2 | Securing holes for Bowden cable assembly: Yes | Open / close cycle (motor), minimum: 3 | Tightening torque of the screw: 8 | Designation, Safety outputs: Y1 and Y2 | Test pulse interval, maximum: 40